discrete module X80 - 8 NO/NC Type C - Isolated relays - 125 V DC/250 V AC - sev
BMXDRC0805H
BMXDRC0805H
BMXDRC0805H
BMXDRC0805H
BMXDRC0805H
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Oferta z czasem realizacji przez producenta
Wysyłka:1 - 2 Dni robocze
Najlepsza cena:
€342.84

Additional Information

Part Number
BMXDRC0805H
Tariff Code
8537109170

Complementary

Mtbf Reliability
2650000 H
Network Frequency
50/60 Hz
Voltage Range
5...150 V || 19...264 V
Electrical Durability
AC-12 200000 cycles 48 VA 24 V -25-60 °C || AC-12 200000 cycles 28.8 VA 24 V 60-70 °C || AC-12 300000 cycles 48 VA 48 V -25-60 °C || AC-12 300000 cycles 28.8 VA 48 V 60-70 °C || AC-12 150000 cycles 96 VA 48 V -25-60 °C || AC-12 150000 cycles 57.6 VA 48 V 60-70 °C || AC-12 300000 cycles 110 VA 100...120 V -25-60 °C || AC-12 300000 cycles 66 VA 100...120 V 60-70 °C || AC-12 150000 cycles 220 VA 100...120 V -25-60 °C || AC-12 150000 cycles 132 VA 100...120 V 60-70 °C || AC-12 300000 cycles 220 VA 200...250 V -25-60 °C || AC-12 300000 cycles 132 VA 200...250 V 60-70 °C || AC-12 150000 cycles 500 VA 200...250 V -25-60 °C || AC-12 150000 cycles 300 VA 200...250 V 60-70 °C || AC-15 700000 cycles 10 VA 24 V -25-60 °C 0.4 ) || AC-15 700000 cycles 6 VA 24 V 60-70 °C 0.4 ) || AC-15 500000 cycles 24 VA 24 V -25-60 °C 0.4 ) || AC-15 500000 cycles 14.4 VA 24 V 60-70 °C 0.4 ) || AC-15 200000 cycles 48 VA 24 V -25-60 °C 0.4 ) || AC-15 200000 cycles 28.8 VA 24 V 60-70 °C 0.4 ) || AC-15 700000 cycles 10 VA 48 V -25-60 °C 0.4 ) || AC-15 700000 cycles 6 VA 48 V 60-70 °C 0.4 ) || AC-15 500000 cycles 24 VA 48 V -25-60 °C 0.4 ) || AC-15 500000 cycles 14.4 VA 48 V 60-70 °C 0.4 ) || AC-15 300000 cycles 48 VA 48 V -25-60 °C 0.4 ) || AC-15 300000 cycles 28.8 VA 48 V 60-70 °C 0.4 ) || AC-15 100000 cycles 96 VA 48 V -25-60 °C 0.4 ) || AC-15 100000 cycles 57.6 VA 48 V 60-70 °C 0.4 ) || AC-15 1000000 cycles 10 VA 100...120 V -25-60 °C 0.4 ) || AC-15 1000000 cycles 6 VA 100...120 V 60-70 °C 0.4 ) || AC-15 300000 cycles 50 VA 100...120 V -25-60 °C 0.4 ) || AC-15 300000 cycles 30 VA 100...120 V 60-70 °C 0.4 ) || AC-15 200000 cycles 110 VA 100...120 V -25-60 °C 0.4 ) || AC-15 200000 cycles 66 VA 100...120 V 60-70 °C 0.4 ) || AC-15 70000 cycles 220 VA 100...120 V -25-60 °C 0.4 ) || AC-15 70000 cycles 132 VA 100...120 V 60-70 °C 0.4 ) || AC-15 1000000 cycles 10 VA 200...250 V -25-60 °C 0.4 ) || AC-15 1000000 cycles 6 VA 200...250 V 60-70 °C 0.4 ) || AC-15 500000 cycles 50 VA 200...250 V -25-60 °C 0.4 ) || AC-15 500000 cycles 30 VA 200...250 V 60-70 °C 0.4 ) || AC-15 200000 cycles 110 VA 200...250 V -25-60 °C 0.4 ) || AC-15 200000 cycles 66 VA 200...250 V 60-70 °C 0.4 ) || AC-15 150000 cycles 220 VA 200...250 V -25-60 °C 0.4 ) || AC-15 150000 cycles 132 VA 200...250 V 60-70 °C 0.4 ) || DC-12 200000 cycles 24 W 24 V -25-60 °C || DC-12 200000 cycles 14.4 W 24 V 60-70 °C || DC-12 150000 cycles 48 W 24 V -25-60 °C || DC-12 150000 cycles 28.8 W 24 V 60-70 °C || DC-12 150000 cycles 40 W 48...60 V -25-60 °C || DC-12 150000 cycles 24 W 48...60 V 60-70 °C || DC-12 100000 cycles 45 W 100...125 V -25-60 °C || DC-12 60000 cycles 45 W 100...125 V 60-70 °C || DC-13 100000 cycles 10 W 24 V -25-60 °C || DC-13 100000 cycles 6 W 24 V 60-70 °C || DC-13 60000 cycles 24 W 24 V -25-60 °C || DC-13 60000 cycles 14.4 W 24 V 60-70 °C || DC-13 40000 cycles 48 W 24 V -25-60 °C || DC-13 40000 cycles 28.8 W 24 V 60-70 °C || DC-13 40000 cycles 40 W 48...60 V -25-60 °C || DC-13 40000 cycles 24 W 48...60 V 60-70 °C || DC-13 100000 cycles 15 W 100...125 V -25-60 °C || DC-13 40000 cycles 15 W 100...125 V 60-70 °C
Typical Current Consumption
40 mA 3.3 V DC || 101 mA 24 V DC
Minimum Switching Current
10 mA 5 V DC
[Ith] Conventional Free Air Thermal Current
4 A 40 °C || 3 A 50 °C || 2 A 60 °C || 1.2 A 70 °C
Output Overvoltage Protection
use discharge diode on each output DC || use RC circuit on each output AC || use ZNO surge limiter on each output AC
Status Led
1 LED (Green) RUN || 1 LED per channel (Green) channel diagnostic || 1 LED (Red) ERR || 1 LED (Red) I/O
Output Short-Circuit Protection
use 1 fast blow fuse per channel or group of channel
Output Overload Protection
use 1 fast blow fuse per channel or group of channel
Insulation Resistance
> 10 MOhm 500 V DC
Network Frequency Limits
47-63 Hz
Protection Type
external short-circuit protection || external overload protection || external overvoltage protection, inductive AC || external overvoltage protection, inductive DC
Power Dissipation In W
3.6 W
Net Weight
0.189 kg
Response Time On Output
<= 10 ms activation || <= 13 ms deactivation
Electrical Connection
40 ways terminal block

Environment

Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-85 °C
Relative Humidity
0-95 % -25-70 °C without condensation
Operating Altitude
0...6561.68 ft (0...2000 m) || 2000...5000 m with derating factor
Shock Resistance
30 gn
Environmental Characteristic
gas resistant class Gx || gas resistant class 3C4 || dust resistant class 3S4 || sand resistant class 3S4 || salt resistant level 2 || mold growth resistant class 3B2 || fungal spore resistant class 3B2
Dielectric Strength
1780 V AC 50/60 Hz 1 min
Vibration Resistance
3 gn
Protective Treatment
conformal coating
Ip Degree Of Protection
IP20

Specifications

Range Of Product
Modicon X80
Discrete Output Number
8 EN/IEC 61131-2
Discrete Output Logic
positive or negative
Product Specific Application
for severe environments
Discrete Output Voltage
5...125 V 5...150 V DC || 24...240 V 19...264 V AC
Product Or Component Type
relay discrete output module

Offer Sustainability

China Rohs Regulation
X
Rohs Exemption Information
Yes
Mercury Free
Yes
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.

Dokumenty

Data Sheet

Pobierz

Powiązane produkty