multifunction relay, Harmony Timer Relays, 8A, 1CO, 0.1s..10 h, power on delay, 12V AC DC
RE17RMJU
RE17RMJU
RE17RMJU
RE17RMJU
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Un total de 33 Parts In-Stock de 17 Distributors

Additional Information

Part Number
RE17RMJU
UNSPSC
39121523
Tariff Code
8536410045
Country of Origin
ID

Specifications

Discrete Output Type
relay
Range Of Product
Harmony Timer Relays
Product Or Component Type
multifunction relay
Time Delay Range
1...10 s || 6...60 s || 10...100 h || 1...10 min || 1...10 h || 0.1...1 s || 6...60 min
Nominal Output Current
8 A
Width
17.5 mm
Time Delay Type
power on-delay || on-delay and off-delay || interval || off-delay || symmetrical flashing
Device Short Name
RE17R

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP121117EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Circularity Profile
ENVEOLI121113EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Safety Reliability Data
MTTFd = 296.8 years || B10d = 270000
Setting Accuracy Of Time Delay
+/- 10 % of full scale 25 °C IEC 61812-1
Height
90 mm
Creepage Distance
4 kV/3 IEC 60664-1
Maximum Delay Response
100 ms
Control Type
selector switch front panel
Insulation Resistance
100 MOhm 500 V DC IEC 60664-1
Maximum Power Consumption In W
0.5 W 12 V DC
Maximum Switching Current
8 A AC/DC
Contacts Material
cadmium free
Power Consumption In Va
0-0.7 VA 12 V AC
Dielectric Strength
2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
Marking
CE
Voltage Range
0.9...1.2 Us
Reset Time
120 ms on de-energisation typical
Operating Rate In Hz
10 Hz
Net Weight
0.07 kg
Mounting Position
any position in relation to normal vertical mounting plane
Voltage Drift
+/- 0.2 %/V
Maximum Switching Voltage
250 V AC
Connections - Terminals
screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
Functionality
multifunction
Contacts Type And Composition
1 C/O
[Us] Rated Supply Voltage
12 V AC/DC 50/60 Hz
Temperature Drift
+/- 0.05 %/°C
Local Signalling
LED indicator on steady: relay energised, no timing in progress || LED indicator 80 % ON and 20 % OFF flashing: timing in progress || LED indicator 5 % ON and 95 % OFF pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L)
Minimum Switching Current
10 mA 5 V DC
Input Voltage
5 V
Mounting Support
35 mm DIN rail conforming to IEC 60715
Electrical Durability
100000 cycles resistive 8 A 250 V AC
Mechanical Durability
10000000 cycles
Compatibility Code
RE17
Breaking Capacity
2000 VA
On-Load Factor
100 %
Housing Material
self-extinguishing
Impulse Duration
100 ms with load in parallel typical || 30 ms typical
Time Delay Type
A, Ac, At, B, Bw, C, D, Di, H, Ht
[Uimp] Rated Impulse Withstand Voltage
5 kV 1.2/50 µs
Depth
72 mm
Tightening Torque
0.6-1 N.m IEC 60947-1
Supply Frequency
50...60 Hz +/- 5 %
Repeat Accuracy
+/- 0.5 % IEC 61812-1

Environment

Product Certifications
CSA || GL || cULus
Ambient Air Temperature For Operation
-20-60 °C
Standards
2006/95/EC || 2004/108/EC || IEC 61000-6-4 || IEC 61000-6-1 || IEC 61000-6-3 || IEC 61812-1 || IEC 61000-6-2
Immunity To Microbreaks
20 ms
Electromagnetic Compatibility
electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2 || electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2 || susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4 || 1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5 || 1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5 || conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6 || voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11 || voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11 || conducted and radiated emissionsclass B EN 55022
Shock Resistance
15 gn 11 ms IEC 60068-2-27
Vibration Resistance
20 m/s² 10-150 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP20 IEC 60529 terminal block) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)
Ambient Air Temperature For Storage
-30-60 °C
Relative Humidity
93-93 % without condensation IEC 60068-2-30