Modular timing relay, Harmony, 8A, 2CO, 0.1s…100h, multifunction, 12V AC DC
RE22R2MJU
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
£45.65
1
Formas de pago:
Un total de 53 Parts In-Stock de 20 Distributors
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
€30.25

Additional Information

Part Number
RE22R2MJU
UNSPSC
39121523
Tariff Code
8536490080
Country of Origin
ID

Complementary

Power Consumption In W
0.5 W 12 V DC
Safety Reliability Data
B10d = 190000 || MTTFd = 205.4 years
Contacts Type And Composition
1 C/O timed contact || 1 C/O timed or instantaneous contact
Setting Accuracy Of Time Delay
+/- 10 % of full scale 25 °C IEC 61812-1
Maximum Delay Response
100 ms
Control Type
rotary knob front panel
Insulation Resistance
100 MOhm 500 V DC IEC 60664-1
Immunity To Microbreaks
10 ms
Power Consumption In Va
1.2-1.2 VA 12 V AC
Minimum Pulse Duration
30 ms || 100 ms under load
Maximum Switching Current
8 mA
Voltage Range
0.9...1.2 Us
Net Weight
0.09 kg
Mounting Position
any position in relation to normal vertical mounting plane
Voltage Drift
+/- 0.2 %/V
Reset Time
120 ms on de-energisation
Maximum Switching Voltage
250 V
Connections - Terminals
screw terminals, 2 x 1.5 mm² with cable end || screw terminals, 2 x 2.5 mm² without cable end
[Us] Rated Supply Voltage
12 V AC/DC
Temperature Drift
+/- 0.05 %/°C
Time Delay Range
1...10 min || 6...60 min || 0.1...1 s || 6...60 s || 1...10 s || 1...10 h || 10...100 h
Minimum Switching Current
10 mA 5 V
Mounting Support
35 mm DIN rail conforming to IEC 60715
Electrical Durability
100000 cycles for resistive load, 8 A at 250 V, AC
Mechanical Durability
10000000 cycles
Breaking Capacity
2000 VA
Housing Material
self-extinguishing
Status Led
Green LED flashing)timing in progress || Green LED steady)power ON || Yellow LEDrelay energised
[Uimp] Rated Impulse Withstand Voltage
5 kV 1.2-50 µs IEC 60664-1 || 5 kV IEC 61812-1
Width
22.5 mm
Time Delay Type
power on-delay || on-delay and off-delay || interval || off-delay || symmetrical flashing
Tightening Torque
0.6-1 N.m IEC 60947-1
Supply Frequency
50...60 Hz +/- 5 %
Repeat Accuracy
+/- 0.5 % IEC 61812-1

Environment

Product Certifications
CSA || cULus || CE || EAC || GL || CCC || RCM
Ambient Air Temperature For Operation
-20-60 °C
Standards
IEC 61000-6-1 || IEC 61812-1 || IEC 61000-6-4 || IEC 61000-6-3 || IEC 61000-6-2
Electromagnetic Compatibility
electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 || electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 || fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 || fast transients immunity test - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 || surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 || surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 || radiated radio-frequency electromagnetic field immunity test - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 || electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 || immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 || immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11 || conducted and radiated emissions class B conforming to EN 55022
Dielectric Strength
2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
Shock Resistance
15 gn 11 ms IEC 60068-2-27
Vibration Resistance
20 m/s² 10-150 Hz)IEC 60068-2-6
Directives
2006/95/EC - low voltage directive || 2004/108/EC - electromagnetic compatibility
Ambient Air Temperature For Storage
-30-60 °C
Relative Humidity
93-93 %, without condensation IEC 60068-2-30
Ip Degree Of Protection
housing IP40 IEC 60529 || terminal block IP20 IEC 60529 || front face IP40 IEC 60529

Specifications

Discrete Output Type
relay
Range Of Product
Harmony Timer Relays
Product Or Component Type
multifunction relay
Nominal Output Current
8 A
Device Short Name
RE22

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1401008EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Circularity Profile
ENVEOLI1401008EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Documentos