Weidmuller
2466890000
PRO TOP1 480W 24V 20A
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
€313.51
1
Formas de pago:
Un total de 12 Parts In-Stock de 13 Distributors
Condiciones del producto:
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
€203.16
Additional Information
- Part Number
- 2466890000
General Data
- AC failure bridging time @ I
- > 20 ms @ 230 V AC / > 20 ms @ 115 V AC
- Conformal coating
- No
- Degree of efficiency
- 93%
- Derating
- > 60°C (2.5% / 1°C)
- Earth leakage current, max.
- 3.5 mA
- Housing version
- Metal, corrosion resistant
- MTBF
- > 1.000.000 h according IEC 1709 (SN29500)
- Mounting position, installation notice
- Horizontal on DIN rail TS 35, top and bottom 50 mm clearance for free air flow, 10 mm clearance to neighbouring active subassemblies with full load, 5 mm with passive neighbouring subassemblies, direct row mounting with 90% rated load
- Operating temperature
- -25 °C...70 °C
- Power factor (approx.)
- > 0.9
- Power loss, idling
- 10 W
- Power loss, nominal load
- 36.1 W
- Protection degree
- IP20
- Series switching capability
- Yes
- Short-circuit protection
- Yes, internal
- Start-up
- ≥ -40 °C
- Surge voltage category
- III
Signalling
- LED green/red
- Green: Operation (failure-free), Flashing green: advance warning I>90%, Green/red flashing: output switched off (switch-off mode), Flashing red: overload/error
Connection Data (Input)
- Conductor cross-section, AWG/kcmil , max.
- 8
- Conductor cross-section, AWG/kcmil , min.
- 20
- Conductor cross-section, flexible , min.
- 0.2 mm²
- Conductor cross-section, rigid , max.
- 10 mm²
- Conductor cross-section, rigid , min.
- 0.2 mm²
- Connection system
- PUSH IN
- Number of terminals
- 3 for L/N/PE
- Screwdriver blade
- 0.6 x 3.5
- Wire connection cross section, flexible (input), max.
- 6 mm²
Approvals
- Approvals
- CULUS, CULUSEX, DNV GL, TUEV
- ROHS
- Conform
- UL File Number Search
- E258476
Dimensions And Weights
- Width
- 68 mm
- Width (inches)
- 2.677 inch
- Height
- 130 mm
- Height (inches)
- 5.118 inch
- Depth
- 125 mm
- Depth (inches)
- 4.921 inch
- Net weight
- 1,520 g
Electrical Safety (Applied Standards)
- Electrical machine equipment
- Acc. to EN60204
- For use with electronic equipment
- Acc. to EN50178 / VDE0160
- Protection against dangerous shock currents
- Acc. to VDE0106-101
- Protective separation / protection against electrical shock
- VDE0100-410 / acc. to DIN57100-410
- Safety extra-low voltage
- SELV according to EN 60950, PELV according to EN 60204
- Safety transformers for switch-mode power supplies
- According to EN 61558-2-16
Emc / Shock / Vibration
- Noise emission in accordance with EN55032
- Class B
- Vibration resistance IEC 60068-2-6
- 2.3 g (on DIN rail), 4 g (with direct mounting)
- Interference immunity test acc. to
- EN 55032:2015, EN 55024:2010/A1:2015, EN 55035:2017, EN 61000-3-2:2014, EN 61000-6-1:2007, EN 61000-6-2:2005, EN 61000-6-3:2007/A1:2011, EN 61000-6-4:2007/A1:2011
- Shock resistance IEC 60068-2-27
- 30 g in all directions
Input
- AC input voltage range
- 85…277 V AC
- Connection system
- PUSH IN
- DC input voltage range
- 80 ... 410 V DC
- Dielectric strength
- max. 300 V AC ≤ 15 s
- Frequency range AC
- 45…65 Hz
- Input fuse (internal)
- Yes
- Inrush current
- max. 5 A
- Rated input voltage
- 100 - 240 V AC / 120 - 340 V DC
- Surge protection
- Varistor
Classifications
- ETIM 6.0
- EC002540
- ETIM 7.0
- EC002540
- EClass 9.0
- 27-04-07-01
- EClass 9.1
- 27-04-07-01
- EClass 10.0
- 27-04-07-01
Output
- DCL - peak load reserve
- 150 % (5 s); 500 % (15 ms)
- Connection system
- PUSH IN
- Mains failure bridge-over time
- > 20 ms @ 115V AC/ 230 VAC
- Nominal output current for U
- 20 A @ 60 °C
- Output power
- 480 W
- Output voltage
- 22.5...28.8 V
- Parallel connection option
- yes, max 10
- Protection against inverse voltage
- Yes
- Ramp-up time
- ≤ 100 ms
- Rated output voltage
- 24 V DC ± 1 %
- Reserve capacity @ U
- 130% permanent at ≤ 40°C, 150 % (5 s)
- Residual ripple, breaking spikes
- < 50 mVss @ UNenn, Full Load
- Triggerable circuit breakers
- C2, C4, C6, B6, B10, B16
Connection Data (Signal)
- Wire connection cross-section, flexible (signal), max.
- 1.5 mm²
- Wire connection cross-section, flexible (signal), min.
- 0.14 mm²
- Wire connection method
- PUSH IN
- Wire cross-section, AWG/kcmil , max.
- 16
- Wire cross-section, AWG/kcmil , min.
- 26
- Wire cross-section, solid , max.
- 1.5 mm²
- Wire cross-section, solid , min.
- 0.14 mm²
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Insulation Coordination
- Humidity at operating temperature
- 5...95 %, no condensation
- Insulation voltage input / earth
- 3.2 kV
- Insulation voltage output / earth
- 0.5 kV
- Insulation voltage, input/output
- 3.5 kV
- Pollution severity
- 2
- Protection class
- I, with PE connection
- Surge voltage category
- III
Connection Data (Output)
- Conductor cross-section, AWG/kcmil , max.
- 8
- Conductor cross-section, AWG/kcmil , min.
- 20
- Conductor cross-section, flexible , max.
- 6 mm²
- Conductor cross-section, flexible , min.
- 0.2 mm²
- Conductor cross-section, rigid , max.
- 10 mm²
- Conductor cross-section, rigid , min.
- 0.2 mm²
- Connection system
- PUSH IN
- Number of terminals
- 5 (+ + / - - -)
- Screwdriver blade
- 0.6 x 3.5
Temperatures
- Humidity at operating temperature
- 5...95 %, no condensation
- Operating temperature, max.
- 70 °C
- Operating temperature, min.
- -25 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -40 °C
- Operating temperature
- -25 °C...70 °C
- Storage temperature
- -40 °C...85 °C
Ratings Iecex/Atex/Cul
- Certificate no. (cULus)
- E258476