TSXDSY08R4DC
- Nuove eccedenze1 pz.
#1 Conferenza per il commercio di automazione industriale| 16-18 giugno 2025| Hilton Warsaw City, Varsavia, PoloniaScopri di più
Categorie
Torna a:Tutte le categorieFiltri
Multi-standard <HAR> hook-up wire: H07V-K, 14 AWG/1C, 750V, UL MTW, TEW
Multi-standard <HAR> hook-up wire: H07V-K, 14 AWG/1C, 750V, UL MTW, TEW
HIS-3 is used in general purpose of electrical insulation with a high level of protection against mechanical abrasion.
HIS-3 is used in general purpose of electrical insulation with a high level of protection against mechanical abrasion.
This green illuminated unit is designed as an accessory to be connected with base and create complete tower light. It is supplied with 24V AC/DC and has a mounting diameter of 60mm. Its integral LED offers a steady light, allowing it to clearly display the status of your machines. In applications such as automotive, machine tool, material handling, packaging, assembly stations, conveyors. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65. It makes it ideal for operation in harsh environments.
This green illuminated unit is designed as an accessory to be connected with base and create complete tower light. It is supplied with 24V AC/DC and has a mounting diameter of 60mm. Its integral LED offers a steady light, allowing it to clearly display the status of your machines. In applications such as automotive, machine tool, material handling, packaging, assembly stations, conveyors. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65. It makes it ideal for operation in harsh environments.
Operating Shaft, Standard Length, 194R, For Use With 140U-P, 194R-P, and 194R-PxT Handles
Operating Shaft, Standard Length, 194R, For Use With 140U-P, 194R-P, and 194R-PxT Handles
Ring cable lug, non-insulated, 10 mm², M6
Ring cable lug, non-insulated, 10 mm², M6
This red illuminated switch head for universal LED provides an ergonomic interface for controlling your machines. It is supplied with standard handle and can easily be installed on compatible selector switch units. It provides a clear help in setting your machines in various operating modes, even in darker control rooms. It offers a clear visual feedback. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP69K. It makes it ideal for operation in harsh environments.
This red illuminated switch head for universal LED provides an ergonomic interface for controlling your machines. It is supplied with standard handle and can easily be installed on compatible selector switch units. It provides a clear help in setting your machines in various operating modes, even in darker control rooms. It offers a clear visual feedback. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP69K. It makes it ideal for operation in harsh environments.
RS-SERIES, Relay module, Number of contacts: 2 CO contact AgNi 90/10, Rated control voltage: 115 V UC +5 % / -15 %, Continuous current: 4 A, Screw connection
RS-SERIES, Relay module, Number of contacts: 2 CO contact AgNi 90/10, Rated control voltage: 115 V UC +5 % / -15 %, Continuous current: 4 A, Screw connection
Plastic label, Card, silver, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 104 x 135 mm, Number of individual labels: 1
Plastic label, Card, silver, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 104 x 135 mm, Number of individual labels: 1
This XCSD Compact Safety Limit Switch has a steel roller lever, a Zamak body and head and a 1/2" NPT cable gland entry. It has 1 normally open and 2 normally closed break-before-make (slow break) contacts. Its B10D reliability data is 50 000 000. It has IK06 impact resistance and IP66 / IP67 degree of protection, makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
This XCSD Compact Safety Limit Switch has a steel roller lever, a Zamak body and head and a 1/2" NPT cable gland entry. It has 1 normally open and 2 normally closed break-before-make (slow break) contacts. Its B10D reliability data is 50 000 000. It has IK06 impact resistance and IP66 / IP67 degree of protection, makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
This design 18 single mode (thru-beam system) photo-electric receiver has a PBT case. It has a supply voltage of 12V to 24V DC. This mono-mode cylindrical photoelectric receiver has a plastic body, is mountable directly on a surface or bracket, thanks to its outer thread and twin nuts. It has VALOX® PBT high strength case ideal for high temperature environments and PMMA scratch-resistant lens for maximum sensor durability. 1 LED display allows to identify status of the sensor. IP65 and IP67 protection makes this product ready for the harshest environments. It can operate in very cold (-25°C) and hot environments (+55°C). It provides double insulation for better people and system protection from electrical shocks. It is CSA and UL certified.
This design 18 single mode (thru-beam system) photo-electric receiver has a PBT case. It has a supply voltage of 12V to 24V DC. This mono-mode cylindrical photoelectric receiver has a plastic body, is mountable directly on a surface or bracket, thanks to its outer thread and twin nuts. It has VALOX® PBT high strength case ideal for high temperature environments and PMMA scratch-resistant lens for maximum sensor durability. 1 LED display allows to identify status of the sensor. IP65 and IP67 protection makes this product ready for the harshest environments. It can operate in very cold (-25°C) and hot environments (+55°C). It provides double insulation for better people and system protection from electrical shocks. It is CSA and UL certified.
DIN rail perforated, acc. to EN 60715, material: Steel, galvanized, passivated with a thick layer, Standard profile, color: silver, Pack of 25 (50 m)
DIN rail perforated, acc. to EN 60715, material: Steel, galvanized, passivated with a thick layer, Standard profile, color: silver, Pack of 25 (50 m)
Device connector front mounting, straight, Screw locking, M23, number of positions: 16, type of contact: Pin, Axial O-ring, 4x √ò 3.2, shielded: yes, degree of protection: IP67, number of positions: 16, connection method: Crimp connection, series: RF
Device connector front mounting, straight, Screw locking, M23, number of positions: 16, type of contact: Pin, Axial O-ring, 4x √ò 3.2, shielded: yes, degree of protection: IP67, number of positions: 16, connection method: Crimp connection, series: RF
Fully hard metal chisel, 1 cutting edge, cutting width: 1.5 mm
Fully hard metal chisel, 1 cutting edge, cutting width: 1.5 mm
Plastic magazine for CMS-P1 plotter. Accepts 1 Weidmüller Multicard mat universal
Plastic magazine for CMS-P1 plotter. Accepts 1 Weidmüller Multicard mat universal
Protective plug PT with protective circuit for a 4-core floating signal circuit. Nominal voltage: 5 V DC
Protective plug PT with protective circuit for a 4-core floating signal circuit. Nominal voltage: 5 V DC
Flush-type connector, Power, 4-position, Socket, straight, M12, T power, PCB mounting, SMD
Flush-type connector, Power, 4-position, Socket, straight, M12, T power, PCB mounting, SMD