Conforme a RoHS
The S802S-B6 is a 2-pole High Performance Circuit breaker with B-characteristic, with cage terminal and a rated current of 6 A. It is a current limiting device with a maximum breaking capacity of 50kA at 240/415V. It can be used for voltages up to 400/690V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S802S-B6 complies with IEC/EN 60947-2 and allows the use for industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S802S-B6 more comfortable. Due to the fast arc extinction of S802S-B6 your application will be secured.
Hai bisogno di ulteriori informazioni?
Chiamaci al:+48 17 778 34 19
Metodi di pagamento:
Dettagli dell'offerta
- Offerta da:
Fornitore di fiducia — Regno Unito, membro dal 2026, 20–49 dipendenti
- Disponibilità:
- 5 pz.Aggiornato il: 07-11-2025Disponibile
- Garanzia:
- Non indicata
- Condizione:
- Nuovo da eccedenze
Nuovo da eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Il venditore è responsabile della spedizione del prodotto e della fatturazione
Specifiche tecniche
- Marchio
- ABB
- American Recovery and Reinvestment Act (ARRA) Compliant
- Contact Manufacturer
- Buy American Act (BAA) Compliant
- Contact Manufacturer
- Recyclability Rate of the Product acc. to EN45555
- Design for Closing Resource Loops - Standard EN45555 - 86.29 %
- ABB Site Meeting Group Waste To Landfill Target
- No non-hazardous waste is sent to a landfill
- Rated Ultimate Short-Circuit Breaking Capacity (Icu)
- (415 V AC) 50 kA || (440 V AC) 30 kA || (500 V AC) 15 kA || (690 V AC) 6 kA || (250 V DC) 30 kA
- Rated Service Short-Circuit Breaking Capacity (Ics)
- (415 V AC) 40 kA || (440 V AC) 22.5 kA || (500 V AC) 11 kA || (690 V AC) 4 kA || (250 V DC) 30 kA
Offerte disponibili
(2)| Condizione | Disponibilità | Fornitore | Garanzia | Azione | |
|---|---|---|---|---|---|
| Condizione Nuovo da eccedenze | Disponibilità 5 pz. Aggiornato il: 07-11-2025Disponibile | Fornitore | Garanzia Non indicata | ||
| Condizione Ricondizionato | Disponibilità 1 pz. Aggiornato il: 07-11-2025Disponibile | Fornitore | Garanzia Non indicata |
Documenti
Scheda tecnica
Scheda tecnica per ABB S802S-B6, incluse specifiche e caratteristiche.
Scarica scheda dati
Modelli CAD
Modello CAD 3D e disegni tecnici, pronti per il tuo software di progettazione.
Scarica modello CAD
Dati del prodotto aggiornati: 07-11-2025

Analisi di mercato per S802S-B6
Ottieni dati analitici e di mercato in tempo reale su S802S-B6 e prodotti simili per ottimizzare le decisioni di acquisto.
- Dati sulla disponibilità di magazzino in tempo reale da oltre 700 distributori MRO in Europa e negli Stati Uniti.
- Analisi dei prezzi per condizione (nuovo, usato, ricondizionato) con prezzi mediani di mercato
- Monitoraggio della disponibilità dei componenti critici per prevenire i tempi di inattività della produzione