Hai bisogno di ulteriori informazioni?

Chiamaci al:+48 17 778 34 19

Honeywell E34-480200-R06XSPKIT-NS

CLASS 3400 SUBMETER - NO SENSORS, 1 or 2 Phase, 200 A, 277/480 V AC

1 / 1
Honeywell E34-480200-R06XSPKIT-NS CLASS 3400 SUBMETER - NO SENSORS, 1 or 2 Phase, 200 A, 277/480 V AC — Alimentazione
Immagine di catalogo del produttore

Descrizione del prodotto

The Class 3400 Smart Meters are equipped with advanced dual protocol communication capabilities, facilitating simultaneous connections to two distinct energy monitoring systems. This feature supports integration with building automation systems for energy monitoring and billing, as well as measurement and verification reporting tools. The optional expanded feature package enhances the product with built-in load control functionalities and two pulse outputs for kWh and kVARh measurement.

Featuring a clear 4-line LCD display with a backlight, the device ensures visibility and ease of use in various lighting conditions. It supports RS485 and Ethernet communication protocols, aligning with industry standards for effective data transmission.

The meter adheres to ANSI C12.20 regulations and is UL/CUL listed, ensuring compliance with safety and performance standards. It operates within a temperature range of -4 °F to 122 °F (-20 °C to 50 °C) and can handle up to 95% non-condensing humidity, making it suitable for a variety of commercial and industrial applications.

With an overall width of 6.5 inches (166 mm), height of 7.8 inches (198 mm), and depth of 3.4 inches (86 mm), the Class 3400 is designed for easy installation. It has a current rating of 200 A and a voltage input configuration of 277/480 V AC with support for both 3 and 4 wire setups. The accuracy is rated at ±1% across a load range from 1% to 100% of its capacity, ensuring reliable performance.

Invia la richiesta
Metodi di pagamento:

Dettagli dell'offerta

Migliore offerta da:
Fornitore di fiducia — Stati Uniti, membro dal 2024
Disponibilità:
0 pz.
Su richiesta
Aggiornato il: 02-09-2026
Garanzia:
12 mesi
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Il venditore è responsabile della spedizione del prodotto e della fatturazione

Specifiche tecniche

Marchio
Honeywell
Regulatory Approvals
ANSI C12.20 ; UL/CUL
Phases
1 or 2
Number of Current Sensors Included
0
Modem Included
No
Minimum Operating Ambient Temperature
-4 °F ; -20 °C
Maximum Operating Humidity
95 % non-condensing

Accedi alla nostra piattaforma per trovare altre offerte

Registratevi ora per esplorare 36 mln di offerte da fornitori verificati in tutto il mondo.

  • Confrontare le offerte a livello globale
  • Contatto diretto con i fornitori
  • RFQ, preventivi e ordini
  • Ricerca della distinta base
RegistratiDisponibile una prova gratuita di 14 giorni
Offerta con tempi di consegna del produttore
Direttamente dal produttore, con tempi di consegna confermati, prevedibili e completamente trasparenti.
Preventivo

Documenti

Scheda tecnica

Scheda tecnica per Honeywell E34-480200-R06XSPKIT-NS, incluse specifiche e caratteristiche.

Scarica scheda dati
TracePartsTraceParts

Modelli CAD

Modello CAD 3D e disegni tecnici, pronti per il tuo software di progettazione.

Scarica modello CAD

Prodotti correlati

E34-480200-J01-X-KIT-NS Honeywell
E34-480200-J01-X-KIT-NS
Honeywell
This submeter is designed for 3-phase electrical monitoring with a current rating of 200 A and supports a voltage configuration of 277/480 V AC.
E34-480200-R04XSPKIT-NS Honeywell
E34-480200-R04XSPKIT-NS
Honeywell
The CLASS 3400 SUBMETER is designed for 1 or 2 phase operation, rated for 200 A at 277/480 V AC, without current sensors.
E34-4001600R01-SPKIT-NS Honeywell
E34-4001600R01-SPKIT-NS
Honeywell
The CLASS 3400 SUBMETER is designed for 1 or 2 phase applications, with a current capacity of 1600 A and operates at 230/400 V AC.
E34-480200-J07KIT Honeywell
E34-480200-J07KIT
Honeywell
The CLASS 3400 SUBMETER supports 3-phase measurement with a maximum current rating of 200 A and operates at 277/480 V AC.
E34-4803200R06-X-KIT-NS Honeywell
E34-4803200R06-X-KIT-NS
Honeywell
Three-phase submeter with a current rating of 3200 A and operating voltage of 277/480 V AC, designed without sensors.
E20-2081600RKIT-NS Honeywell
E20-2081600RKIT-NS
Honeywell
CLASS 2000 SUBMETER - NO SENSORS, 3 Phase, 1600 A, 120/208-240 V AC provides detailed kW and kWh data for three-phase power systems.
E34-400200-R01-SPSCS-NS Honeywell
E34-400200-R01-SPSCS-NS
Honeywell
The CLASS 3400 SUBMETER is designed for 1 or 2 phase applications, supporting up to 200 A and operating at 230/400 V AC.
E34-4803200J01XSPKIT Honeywell
E34-4803200J01XSPKIT
Honeywell
The CLASS 3400 SUBMETER provides dual protocol communications for energy monitoring, capable of handling 1 or 2 phases at 3200 A and 277/480 V AC.
E50-4001600R04KIT-NS Honeywell
E50-4001600R04KIT-NS
Honeywell
The CLASS 5000 SUBMETER is a 3-phase smart meter designed for 1600 A and operates at 230/400 V AC, featuring advanced dual protocol communications.
E50-4801600R05-SPKIT-NS Honeywell
E50-4801600R05-SPKIT-NS
Honeywell
The 5000 Series Submeter operates without sensors, supporting 1 or 2 phase configurations with a capacity of 1600 A at 277/480 V AC.
E34-208100-R08-SPSCS Honeywell
E34-208100-R08-SPSCS
Honeywell
The CLASS 3400 SUBMETER is designed for 1 or 2 phase applications, supporting a maximum current of 100 A and operating at 120/208-240 V AC.
E10-2120200JSCS-NS Honeywell
E10-2120200JSCS-NS
Honeywell
The CLASS 1000 SUBMETER is designed for single-phase power measurement, providing kW and kWh data without sensors.

Approfondimenti sul mercato

AutomaINSIGHTS cruscotto di analisi

Ottenere dati analitici e di mercato in tempo reale per ottimizzare le decisioni di acquisto di questo componente e di prodotti simili

  • Dati sulla disponibilità di magazzino in tempo reale da oltre 700 distributori MRO in Europa e negli Stati Uniti.
  • Analisi dei prezzi per condizione (nuovo, usato, ricondizionato) con prezzi mediani di mercato
  • Monitoraggio della disponibilità dei componenti critici per prevenire i tempi di inattività della produzione
  • Ottimizzazione dell'inventario in base alle tendenze di approvvigionamento del mercato
Inizia