Hai bisogno di ulteriori informazioni?

Chiamaci al:+48 17 778 34 19

Honeywell E34-480400-J05KIT-NS

CLASS 3400 SUBMETER - NO SENSORS, 3 Phase, 400 A, 277/480 V AC

1 / 1
Honeywell E34-480400-J05KIT-NS CLASS 3400 SUBMETER - NO SENSORS, 3 Phase, 400 A, 277/480 V AC — Alimentazione
Immagine di catalogo del produttore

Descrizione del prodotto

The Class 3400 (H34) Smart Meter variant is engineered for advanced energy monitoring in commercial and industrial settings. It supports dual protocol communications, allowing integration with up to two energy monitoring systems simultaneously, including building automation systems and measurement and verification reporting tools.

This model does not include current sensors and operates with a 3 or 4-wire input voltage configuration. The 4-line LCD display features backlighting for enhanced visibility, while communication is facilitated through RS485 and Ethernet interfaces. With an accuracy of ±1% across the rated load range, it effectively monitors electrical usage.

The environmental specifications are noteworthy, with a minimum operating temperature of -4 °F (-20 °C) and a maximum threshold of 122 °F (50 °C), alongside a tolerable humidity level of up to 95% non-condensing. Regulatory approvals include ANSI C12.20 and UL/CUL certifications, ensuring compliance and reliability. The enclosure is constructed from JIC steel, contributing to its durability in diverse operational conditions.

Invia la richiesta
Metodi di pagamento:

Dettagli dell'offerta

Migliore offerta da:
Fornitore di fiducia — Stati Uniti, membro dal 2024
Disponibilità:
0 pz.
Su richiesta
Aggiornato il: 02-09-2026
Garanzia:
12 mesi
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Il venditore è responsabile della spedizione del prodotto e della fatturazione

Specifiche tecniche

Marchio
Honeywell
Regulatory Approvals
ANSI C12.20 ; UL/CUL
Phases
3
Number of Current Sensors Included
0
Modem Included
No
Minimum Operating Ambient Temperature
-4 °F ; -20 °C
Maximum Operating Humidity
95 % non-condensing

Accedi alla nostra piattaforma per trovare altre offerte

Registratevi ora per esplorare 36 mln di offerte da fornitori verificati in tutto il mondo.

  • Confrontare le offerte a livello globale
  • Contatto diretto con i fornitori
  • RFQ, preventivi e ordini
  • Ricerca della distinta base
RegistratiDisponibile una prova gratuita di 14 giorni
Offerta con tempi di consegna del produttore
Direttamente dal produttore, con tempi di consegna confermati, prevedibili e completamente trasparenti.
Preventivo

Documenti

Scheda tecnica

Scheda tecnica per Honeywell E34-480400-J05KIT-NS, incluse specifiche e caratteristiche.

Scarica scheda dati
TracePartsTraceParts

Modelli CAD

Modello CAD 3D e disegni tecnici, pronti per il tuo software di progettazione.

Scarica modello CAD

Prodotti correlati

E34-400100-R07SCS Honeywell
E34-400100-R07SCS
Honeywell
The CLASS 3400 SUBMETER is a 3-phase, 100 A meter designed for 230/400 V AC applications, featuring advanced dual protocol communications.
E34-400400-R03KIT Honeywell
E34-400400-R03KIT
Honeywell
The CLASS 3400 SUBMETER is a 3-phase energy meter capable of handling 400 A at 230/400 V AC, designed for advanced energy monitoring.
E34-480200-R04XSPKIT-NS Honeywell
E34-480200-R04XSPKIT-NS
Honeywell
The CLASS 3400 SUBMETER is designed for 1 or 2 phase operation, rated for 200 A at 277/480 V AC, without current sensors.
E34-480200-R06XSPKIT-NS Honeywell
E34-480200-R06XSPKIT-NS
Honeywell
The CLASS 3400 SUBMETER is configured for 1 or 2 phases, handling up to 200 A and operating at 277/480 V AC without any current sensors.
E34-480200-R08KIT Honeywell
E34-480200-R08KIT
Honeywell
The 3400 Submeter is a three-phase energy meter rated for 200 A and designed for 277/480 V AC systems.
E34-400200-J04-X-KIT-NS Honeywell
E34-400200-J04-X-KIT-NS
Honeywell
The CLASS 3400 SUBMETER is designed for 3-phase applications, rated at 200 A with an input voltage of 230/400 V AC.
E34-480200-J01-X-KIT-NS Honeywell
E34-480200-J01-X-KIT-NS
Honeywell
This submeter is designed for 3-phase electrical monitoring with a current rating of 200 A and supports a voltage configuration of 277/480 V AC.
E34-480800-J03-X-KIT-NS Honeywell
E34-480800-J03-X-KIT-NS
Honeywell
The CLASS 3400 SUBMETER is a three-phase electronic meter designed for monitoring electrical usage with a maximum current of 800 A and input voltage of 277/480 V AC.

Approfondimenti sul mercato

AutomaINSIGHTS cruscotto di analisi

Ottenere dati analitici e di mercato in tempo reale per ottimizzare le decisioni di acquisto di questo componente e di prodotti simili

  • Dati sulla disponibilità di magazzino in tempo reale da oltre 700 distributori MRO in Europa e negli Stati Uniti.
  • Analisi dei prezzi per condizione (nuovo, usato, ricondizionato) con prezzi mediani di mercato
  • Monitoraggio della disponibilità dei componenti critici per prevenire i tempi di inattività della produzione
  • Ottimizzazione dell'inventario in base alle tendenze di approvvigionamento del mercato
Inizia