Honeywell HVFDSB3C0015G330/U

VFD with Bypass and Disconnect, 480Vac, 1.5HP, Graphical, NEMA 3R Enclosure, Three Contactor Bypass

1 / 3
Honeywell HVFDSB3C0015G330/U VFD with Bypass and Disconnect, 480Vac, 1.5HP, Graphical, NEMA 3R Enclosure, Three Contactor Bypass — Inverter e convertitori di frequenza
Immagine di catalogo del produttore
Honeywell HVFDSB3C0015G330/U VFD with Bypass and Disconnect, 480Vac, 1.5HP, Graphical, NEMA 3R Enclosure, Three Contactor Bypass — Inverter e convertitori di frequenza
Immagine di catalogo del produttore
Honeywell HVFDSB3C0015G330/U VFD with Bypass and Disconnect, 480Vac, 1.5HP, Graphical, NEMA 3R Enclosure, Three Contactor Bypass — Inverter e convertitori di frequenza
Immagine di catalogo del produttore
Honeywell HVFDSB3C0015G330/U VFD with Bypass and Disconnect, 480Vac, 1.5HP, Graphical, NEMA 3R Enclosure, Three Contactor Bypass — Inverter e convertitori di frequenza
Honeywell HVFDSB3C0015G330/U VFD with Bypass and Disconnect, 480Vac, 1.5HP, Graphical, NEMA 3R Enclosure, Three Contactor Bypass — Inverter e convertitori di frequenza
Honeywell HVFDSB3C0015G330/U VFD with Bypass and Disconnect, 480Vac, 1.5HP, Graphical, NEMA 3R Enclosure, Three Contactor Bypass — Inverter e convertitori di frequenza

Descrizione del prodotto

The variable frequency drive (VFD) supports HVAC systems by efficiently modulating the speed of pumps and fans, thus promoting energy conservation. This model, equipped with a three contactor bypass, operates at a voltage of 460 (3PH) V AC and includes a graphical interface for simplified programming and commissioning.

With a NEMA 3R enclosure, it is designed to withstand harsh environments while functioning optimally at ambient temperatures ranging from 14 °F (-10 °C) to 104 °F (40 °C). The VFD’s continuous output current is rated at 3.4 A, with overload capabilities of 1.1 times the current for specified durations. It also features a minimum operating humidity of 0% and can tolerate up to 95% humidity at maximum operating conditions.

Additional specifications include an overall width of 24.5 inches (622 mm), height of 24 inches (610 mm), and depth of 12 inches (305 mm), weighing 24.5 lbs (54 kg). The drive supports both analog inputs and outputs for enhanced flexibility in control, with selectable ranges for precise system integration. Compliance with regulatory standards such as CE and EN 61800-5-1 ensures reliability and safety in operation.

Hai bisogno di ulteriori informazioni?

Chiamaci al:+48 17 778 34 19
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
Metodi di pagamento:
Richiedete un preventivo e vi invieremo informazioni su disponibilità e prezzi.

Specifiche tecniche

Marchio
Honeywell
Type of RFI Filter
EMC Filter
Relay Rated Load
Max load: 250Vac/2A- 250Vdc/0.4A
Regulatory Approvals
CE ; EN 61800-5-1 ; cUL
Reference Output Voltage
10 Vdc- max load 10 mA
Pilot Lights
Yes
Peak Current
IS- 2s/20s

Documenti

Scheda tecnica

Scheda tecnica per Honeywell HVFDSB3C0015G330/U, incluse specifiche e caratteristiche.

Scarica scheda dati
TraceParts

Modelli CAD

Modello CAD 3D e disegni tecnici, pronti per il tuo software di progettazione.

Scarica modello CAD
Dashboard analitica AutomaINSIGHTS per HVFDSB3C0015G330/U

Analisi di mercato per HVFDSB3C0015G330/U

Ottieni dati analitici e di mercato in tempo reale su HVFDSB3C0015G330/U e altri prodotti della categoria Inverter e convertitori di frequenza per ottimizzare le decisioni di acquisto.

  • Dati sulla disponibilità di magazzino in tempo reale da oltre 700 distributori MRO in Europa e negli Stati Uniti.
  • Analisi dei prezzi per condizione (nuovo, usato, ricondizionato) con prezzi mediani di mercato
  • Monitoraggio della disponibilità dei componenti critici per prevenire i tempi di inattività della produzione

Categorie correlate