1 / 2
thumbnail
thumbnail

Descrizione

Attivo maturo
The Acti9 iEM3000 series energy meters offer an attractive range of three-phase DIN rail-mounted energy meters with an LCD display. Additional local signaling includes green LED power-on indicator, flashing yellow LED for accuracy checking, an overload alarm and communication indicators. This meter can be used in sub-billing applications and supports 4 tariff schedules. The meter provides the following accuracy classes: Active Energy: class 0.5S per IEC 62053-22, Active Energy: class C per EN 50470-3 and Active Energy: class 0.5S per IEC 61557-12. The meter will measure Active and Reactive Power, Active and Reactive Energy, Voltage and Current. With four quadrant Energy measurement. Designed for 50Hz or 60Hz networks, supply voltage can range from 100 to 277VAC or 173 to 480VAC. The rated current goes through a 1A or 5A transfomer to be measured in this meter and will support Single Phase and Neutral, Three Phase and Three Phase and Neutral configurations. Communication protocol is M-Bus with screw terminal support. There is one programmable digital input and one programmable digital output that can be used as a pulsed output. Certifications include EAC, CE, UL and MID. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.72in (69 mm), height 3.74 in (95 mm) and product weight 9.17 oz (260 g).
Country of Origin
CN
Part Number
A9MEM3235
Tariff Code
90283019
EAN
3606480616501
UNSPSC
40151552
€242.10
net
€269.00
Spedizione da:
€25.00
1
Metodi di pagamento:
Migliore offerta da:
CZFornitore Automa.Net di fiducia
Disponibilità:
1 pz.
Disponibile
Aggiornato il: 04-11-2024
Garanzia:
24 mesi
Consegna stimata:
11-12 novembre a Regno Unito
Condizione:
Usato
Usato - Un articolo usato in precedenza con possibili segni di usura estetica. È completamente operativo e funziona come previsto, anche se l'imballaggio originale potrebbe mancare.
Informazioni sulla spedizione
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Environment

Height
95 mm
Ambient Air Temperature For Operation
-25-70 °C - IEC
Pollution Degree
2
9 Mm Pitches
10
Color
White
Ambient Air Temperature For Storage
-40-85 °C
Relative Humidity
5-95 % 50-50 °C
Ip Degree Of Protection
front panel IP40 IEC 60529 || body IP20 IEC 60529
Width
90 mm
Depth
69 mm
Operating Altitude
< 6561.68 ft (2000 m)

Complementary

Network Frequency
60 Hz || 50 Hz
Communication Port Support
screw terminal block M-Bus
Output Voltage
5...40 V DC@50 mA
Sampling Rate
32 samples/cycle
Number Of Outputs
1 digital (static)
Mounting Support
DIN rail
Maximum Value Measured
99999999 MWh
Standards
BS EN 61557-12:2021 || IEC 61557-12:2021 || EN 61557-12:2021 || BS EN 61326-1 || IEC 61326-1 || EN 61326-1 || BS EN 62052-11:2020 || IEC 62052-11:2020 || EN 62052-11:2020 || BS EN 62053-21 || IEC 62053-21 || EN 62053-21 || BS EN 62052-22 || IEC 62053-22:2020 || EN 62052-22 || BS EN 62052-23 || IEC 62053-23:2020 || EN 62052-23 || BS EN 62052-31:2015 || IEC 62052-31:2015 || EN 62052-31:2015 || BS EN 61010-1:2010 || EN 61010-1:2010 || IEC 61010-1:2010 || UL 61010-1:2010 || BS EN 61010-2-30 || IEC 61010-2-30 || EN 61010-2-30 || UL 61010-2-30 || BS EN 50470-3 || EN 50470-3 || BS EN 50470-1 || EN 50470-1 || ANSI C12.20
Type Of Measurement
active and reactive energy || active and reactive power || current || voltage
Communication Port Protocol
M-bus 300, 600, 1200, 2400, 4800 and 9600 bauds 3750 V
Product Certifications
CE IEC 61010-1 safety) || CE EN 61557-12 power monitor) || CE EN/IEC 61326-1 EMC) || UKCA BS EN 61010-1 safety) || UKCA BS EN 61557-12 power monitor) || UKCA BS EN 61326-1 EMC) || cULus UL 61010-1 safety) || cULus EN 61010-1 safety) || EAC EN 50470-3 sub-meter) || RCM EN 62052 sub-meter) || KZ EN 50470-3 sub-meter) || METAS EN 50470-1 sub-meter) || MID EN 50470-3 sub-meter) || MID EN 50470-1 sub-meter) || NMI NMI M 6-1
Number Of Inputs
1 digital 0...5 V/11...40 V 24 V DC
Measurement Current
1-32767000 mA
Connections - Terminals
current circuit screw terminals 6-6 mm² || voltage circuit screw terminals 2.5-2.5 mm²
Information Displayed
tariff 4)
Typical Current Consumption
communication M-bus: 2.3 mA at state 1
Mounting Mode
clip-on
Local Signalling
Green indicator light power ON || Yellow flashing LED accuracy checking || alarm overload
Technology Type
electronic
Poles Description
3P || 1P + N || 3P + N
Line Rated Current
5 A || 1 A
Analogue Input Type
external CT 1 A or 5 A
Display Type
LCD display
Overvoltage Category
III
Device Application
sub billing || partial meter || multi-tariff
Metering Type
active, reactive, apparent energy (signed, four quadrant)
Accuracy Class
class 0.5S active energy IEC 62053-22 || class 0.5S active energy IEC 61557-12 || class C active energy EN 50470-3
Rated Voltage
100-277 V || 173-480 V

Specifications

Product Or Component Type
energy meter
Product Name
Acti9 iEM3000
Range
Acti9
Device Short Name
iEM3235

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111276EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI111261EN_V1
Eu Rohs Directive
Compliant with Exemptions

Modelli CAD

traceparts
traceparts
Scaricare