TeSys GV motor circuit breaker, 3 poles (3P), 12.5A/690V, for protection of 3-phase motors 3-5.5kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 5-12.5A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
Country of Origin
PL
Part Number
GV4PE12N
Tariff Code
85362010
EAN
3606481310262
Metodi di pagamento:
Migliore offerta da:
SKFornitore Automa.Net di fiducia
Disponibilità:
10 pz.
Disponibile
Aggiornato il: 22-11-2024
Garanzia:
12 mesi
Consegna stimata:
Su richiesta
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Un totale di 12 Parts In-Stock da 2 Distributors
Consegna da:
SK
SK
US
US
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Offerte Disponibili (1)

GV4PE12N product image
Schneider Electric

GV4PE12N

Condizione:
Nuove eccedenze
Disponibile:
2 pz.
Disponibile
Aggiornato il: 22-11-2024
Offerta da:
USAutoma.Net Fornitore
Consegna stimata:
Su richiesta
1
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
€85.11

Environment

Product Certifications
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Ik Degree Of Protection
IK07 IEC 62262
Ambient Air Temperature For Operation
-25-70 °C
Standards
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Climatic Withstand
IACS E10
Pollution Degree
3
Ambient Air Temperature For Storage
-50-85 °C
Ip Degree Of Protection
IP40 IEC 60529
Operating Altitude
5000 m
Fire Resistance
960 °C IEC 60695-2-11

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1704004EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI1704004EN
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free plastic parts product

Complementary

Mechanical Robustness
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Line Rated Current
12.5 A
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz IEC 60947-2
Height
155 mm
Phase Failure Sensitivity
yes IEC 60947-4-1
Rated Duty
continuous IEC 60947-4-1
Magnetic Tripping Current
212-212 A
[Ith] Conventional Free Air Thermal Current
115 A IEC 60947-4-1
Motor Power Kw
3-3 kW 400...415 V AC 50/60 Hz || 3-3 kW 500 V AC 50/60 Hz || 4-4 kW 500 V AC 50/60 Hz || 5.5-5.5 kW 660...690 V AC 50/60 Hz || 7.5-7.5 kW 660...690 V AC 50/60 Hz || 4-4 kW 400...415 V AC 50/60 Hz || 5.5-5.5 kW 400...415 V AC 50/60 Hz || 5.5-5.5 kW 500 V AC 50/60 Hz || 7.5-7.5 kW 500 V AC 50/60 Hz || 9-9 kW 660...690 V AC 50/60 Hz || 11-11 kW 660...690 V AC 50/60 Hz
Maximum Operating Rate
25 cyc/h
Operating Position
any position
Connections - Terminals
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Utilisation Category
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Net Weight
1.45 kg
[Uimp] Rated Impulse Withstand Voltage
8 kV IEC 60947-2
Control Type
toggle
Power Dissipation Per Pole
4.6 W
Electrical Durability
40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Breaking Capacity
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz UL 60947 || 35 kA 480Y/277 V AC 50/60 Hz UL 60947 || 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 || 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 18 kA 600Y/347 V AC 50/60 Hz UL 60947
Suitability For Isolation
yes IEC 60947-1
[Ui] Rated Insulation Voltage
800 V AC 50/60 Hz IEC 60947-2
Tightening Torque
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Mechanical Durability
40000 cycles
Poles Description
3P
Color
Gray RAL 7016)
Width
81 mm
Depth
116 mm

Specifications

Range Of Product
TeSys GV4
Product Or Component Type
motor circuit breaker
Product Name
TeSys GV4 || TeSys Deca
Range
TeSys Deca
Device Application
motor protection
Device Short Name
GV4PE
Trip Unit Technology
electronic || thermal-magnetic

Modelli CAD

traceparts
traceparts
Scaricare