Auxiliary contact block,TeSys Giga contactor,1NO+1NC,side mounting,push-in terminals
LAG8N113
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
1
Metodi di pagamento:
Un totale di 47 Parts In-Stock da 19 Distributors

Additional Information

Part Number
LAG8N113
UNSPSC
39121522
Tariff Code
8536509065

Complementary

Non-Overlap Time
1.5 ms on de-energisation no overlap between NC and NO contact || 1.5 ms on energisation no overlap between NC and NO contact
Permissible Short-Time Rating
100 A 60 °C 1 s || 120 A 60 °C 500 ms || 140 A 60 °C 100 ms
Minimum Switching Current
1 mA
Height
55.8 mm
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C)
[Ue] Rated Operational Voltage
500 V AC 25...400 Hz
Protection Type
gG fuse 10 A
Insulation Resistance
> 10 MOhm
Irms Rated Making Capacity
140 A AC conforming to IEC 60947-5-1 || 250 A DC conforming to IEC 60947-5-1
Net Weight
0.05 kg
Mounting Location
side
[Ui] Rated Insulation Voltage
500 V IEC 60947-5-1 || 500 V CSA || 500 V UL
Minimum Switching Voltage
17 V
Mechanical Durability
8 Mcycles
Width
15.4 mm
Depth
84.8 mm

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free plastic parts product

Specifications

Range Of Product
TeSys G
Range Compatibility
TeSys G LC1G
Product Or Component Type
auxiliary contact block
Connections - Terminals
screw clamp terminals 0.75-2.5 mm²solid stranded without cable end || screw clamp terminals 0.75-2.5 mm²flexible with cable end
Range
TeSys
Pole Contact Composition
1 NO + 1 NC
Auxiliary Contacts Operation
instantaneous
Device Short Name
LAG8N

Environment

Product Certifications
CB Scheme || CCC || cULus || CE || UKCA || EU-RO-MR by DNV-GL || EAC
Ambient Air Temperature For Operation
-25-60 °C
Standards
EN/IEC 60947-5-1 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || GB 14048.5
Ip Degree Of Protection
IP20 conforming to IEC 60529
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH
Operating Altitude
9842.52 ft (3000 m)