1 / 1
thumbnail

Descrizione

Attivo maturo
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 9A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 2HP at 200 to 208VAC, 2HP at 240VAC, 5HP at 480VAC and 7.5HP at 600VAC three phase. Contactor is also rated for 0.33HP at 115VAC and 1HP at 240VAC single phase. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as stanard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.06 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
Country of Origin
ID
Part Number
LC1D093BL
Tariff Code
85364190
EAN
3389110808483
UNSPSC
39121529
€39.00
net
1
Metodi di pagamento:
Migliore offerta da:
DEAutoma.Net Fornitore
Disponibilità:
4 pz.
Disponibile
Aggiornato il: 02-10-2023
Consegna stimata:
Su richiesta
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Un totale di 440 Parts In-Stock da 30 Distributors
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Offerte Disponibili (40)

Migliore offerta
LC1D093BL product image
Schneider Electric

LC1D093BL

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 30-09-2024
Offerta da:
GBFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
£36.89
net
LC1D093BL product image
Schneider Electric

LC1D093BL

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
21 pz.
Disponibile
Aggiornato il: 04-11-2024
Offerta da:
GBFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
£62.71
net
LC1D093BL product image
Schneider Electric

LC1D093BL

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
26 pz.
Disponibile
Aggiornato il: 04-11-2024
Offerta da:
NLFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€67.64
net
LC1D093BL product image
Schneider Electric

LC1D093BL

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
13 pz.
Disponibile
Aggiornato il: 04-11-2024
Offerta da:
ITFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€68.60
net
LC1D093BL product image
Schneider Electric

LC1D093BL

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
26 pz.
Disponibile
Aggiornato il: 04-11-2024
Offerta da:
DEFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€70.90
net
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
€16.63

Environment

Product Certifications
UL || GOST || CSA || CCC || GL || BV || LROS (Lloyds register of shipping) || DNV || RINA || UKCA
Height
99 mm
Standards
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Climatic Withstand
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Net Weight
0.48 kg
Flame Retardance
V1 conforming to UL 94
Protective Treatment
THIEC 60068-2-30
Ip Degree Of Protection
IP20 front face IEC 60529
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Operating Altitude
0...9842.52 ft (0...3000 m)
Fire Resistance
850 °C IEC 60695-2-1
Width
45 mm
Depth
95 mm
Permissible Ambient Air Temperature Around The Device
-40-60 °C || 60-70 °C with derating

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110230EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Toxic Heavy Metal Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI1102030EN
Eu Rohs Directive
Compliant with Exemptions

Complementary

Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Minimum Switching Current
5 mA for signalling circuit
Power Dissipation Per Pole
1.56 W AC-1 || 0.2 W AC-3 || 0.2 W AC-3e
Average Impedance
2.5 mOhm - Ith 16 A 50 Hz for power circuit
Auxiliary Contact Composition
1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C) for signalling circuit || 16 A (at 60 °C) for power circuit
Control Circuit Voltage Limits
0.1...0.3 Uc -40-70 °C drop-out DC || 0.8...1.25 Uc -40-60 °C operational DC || 1...1.25 Uc 60-70 °C operational DC
Mounting Support
rail || plate
Contact Compatibility
M5
Control Circuit Type
DC low consumption
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pollution Degree
3
Hold-In Power Consumption In W
2.4-2.4 W 20 °C
Insulation Resistance
> 10 MOhm for signalling circuit
Rated Breaking Capacity
250 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947
Pole Contact Composition
3 NO
Connections - Terminals
power circuit: spring terminals 1 2.5-2.5 mm² - cable stiffness: flexible without cable end || power circuit: spring terminals 2 2.5-2.5 mm² - cable stiffness: flexible without cable end || control circuit: spring terminals 1 2.5-2.5 mm² - cable stiffness: flexible without cable end || control circuit: spring terminals 2 2.5-2.5 mm² - cable stiffness: flexible without cable end
Coil Technology
built-in bidirectional peak limiting diode suppressor
Time Constant
40 ms
Operating Time
77 ±15 % ms closing || 25 ±20 % ms opening
Minimum Switching Voltage
17 V for signalling circuit
Maximum Operating Rate
3600 cyc/h 60 °C
Signalling Circuit Frequency
25...400 Hz
Electrical Durability
0.6 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 9 A AC-3 <= 440 V || 2 Mcycles 9 A AC-3e <= 440 V
Mechanical Durability
30 Mcycles
Inrush Power In W
2.4-2.4 W 20 °C)
Auxiliary Contacts Type
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Compatibility Code
LC1D
Overvoltage Category
III
Maximum Horse Power Rating
1 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors || 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
Motor Power Kw
2.2 kW at 220...230 V AC 50/60 Hz (AC-3) || 4 kW at 380...400 V AC 50/60 Hz (AC-3) || 4 kW at 415 V AC 50/60 Hz (AC-3) || 4 kW at 440 V AC 50/60 Hz (AC-3) || 5.5 kW at 500 V AC 50/60 Hz (AC-3) || 5.5 kW at 660...690 V AC 50/60 Hz (AC-3) || 2.2 kW at 220...230 V AC 50/60 Hz (AC-3e) || 4 kW at 380...400 V AC 50/60 Hz (AC-3e) || 4 kW at 415 V AC 50/60 Hz (AC-3e) || 4 kW at 440 V AC 50/60 Hz (AC-3e) || 5.5 kW at 500 V AC 50/60 Hz (AC-3e) || 5.5 kW at 660...690 V AC 50/60 Hz (AC-3e) || 2.2 kW at 400 V AC 50/60 Hz (AC-4)
[Ui] Rated Insulation Voltage
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
[Icw] Rated Short-Time Withstand Current
105 A 40 °C - 10 s for power circuit || 210 A 40 °C - 1 s for power circuit || 30 A 40 °C - 10 min for power circuit || 61 A 40 °C - 1 min for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
Protective Cover
with

Specifications

[Uc] Control Circuit Voltage
24 V DC
[Ue] Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Range Of Product
TeSys Deca
Contactor Application
resistive load || motor control
Product Or Component Type
contactor
Utilisation Category
AC-1 || AC-3 || AC-4 || AC-3e
[Ie] Rated Operational Current
9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 20 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Poles Description
3P
Device Short Name
LC1D