Schneider Electric LC1D40AFC7

IEC Contactor, TeSys Deca, Nonreversing, 40A, 30HP at 480VAC, 3 Phase with 127VAC Coil

1 / 1
Schneider Electric LC1D40AFC7 IEC Contactor, TeSys Deca, Nonreversing, 40A, 30HP at 480VAC, 3 Phase with 127VAC Coil
Immagine di catalogo del produttore

Descrizione del prodotto

Ciclo di vita:

The TeSys D contactor is engineered for integration within control systems, facilitating motor starters across various applications. This specific model supports inductive loads up to 40A and can handle resistive loads reaching 200A. It is designed with three poles and features a 127VAC coil.

With a height of 4.80 inches, a width of 2.17 inches, and a depth of 4.72 inches, the contactor has a net weight of 1.87 lbs. It is capable of being mounted on DIN rail or directly onto panels, and it incorporates a range of horsepower ratings for international compatibility, including 10HP at 200-208VAC, 10HP at 240VAC, and 30HP at 480VAC and 600VAC.

When utilized within a 480VAC circuit breaker rated up to 110A, the contactor achieves a Short-Circuit Current Rating (SCCR) of up to 100kA. For applications using Class J or CC fuses rated for up to 600VAC and 90A, the same SCCR is attainable. The device includes one normally open and one normally closed auxiliary contact, with the NC contact being mirror certified.

Compliant with multiple international standards, including UL and CSA, this contactor is also certified to meet RoHS/REACh requirements, positioning it as a Green Premium product. It is equipped with screw clamp terminals for load and auxiliary connections, and a comprehensive range of accessories is available to fulfill various application needs. The operational temperature range is -40°C to 60°C, with a maximum altitude of 3000 meters, ensuring reliability in diverse...

Invia la richiesta
Metodi di pagamento:

Dettagli dell'offerta

Migliore offerta da:
Fornitore di fiducia — Romania, membro dal 2023, 1–4 dipendenti
Disponibilità:
1 pz.
Su richiesta
Aggiornato il: 22-08-2026
Condizione:
Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Il venditore è responsabile della spedizione del prodotto e della fatturazione

Specifiche tecniche

Product Certifications
UL || CCC || GOST || CSA
Standards
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Climatic Withstand
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Flame Retardance
V1 conforming to UL 94
Protective Treatment
THIEC 60068-2-30
Ip Degree Of Protection
IP20 front face IEC 60529

Offerte Disponibili

(2)
LC1D40AFC7 Schneider Electric

Schneider Electric

Disponibile:
0 pz.
Su richiesta
Aggiornato il: 05-09-2026
Offerta da:
Fornitore di fiducia — Italia, membro dal 2021, 10–19 dipendenti
Garanzia:
12 mesi

Accedi alla nostra piattaforma per trovare altre offerte

Registratevi ora per esplorare 36 mln di offerte da fornitori verificati in tutto il mondo.

  • Confrontare le offerte a livello globale
  • Contatto diretto con i fornitori
  • RFQ, preventivi e ordini
  • Ricerca della distinta base
RegistratiDisponibile una prova gratuita di 14 giorni
Offerta con tempi di consegna del produttore
Direttamente dal produttore, con tempi di consegna confermati, prevedibili e completamente trasparenti.
Preventivo

Documenti

Scheda tecnica

Scheda tecnica per Schneider Electric LC1D40AFC7, incluse specifiche e caratteristiche.

Scarica scheda dati
TracePartsTraceParts

Modelli CAD

Modello CAD 3D e disegni tecnici, pronti per il tuo software di progettazione.

Scarica modello CAD

Prodotti compatibili

GV3G264 Schneider Electric
GV3G264
Schneider Electric
TeSys GV busbar set, 3 phases, rated for 115A at 690V, designed for upstream parallel wiring of motor starters using GV3 motor circuit breakers.
LA4DT0U Schneider Electric
LA4DT0U
Schneider Electric
TeSys Deca electronic timer module for LC1D09-D38, LC1D40A-D80A, LC1D80-D150 (3P) contactors
LA4DT2U Schneider Electric
LA4DT2U
Schneider Electric
TeSys Deca electronic timer module for LC1D09-D38, LC1D40A-D80A, LC1D80-D150 (3P) contactors
LA4DT4U Schneider Electric
LA4DT4U
Schneider Electric
TeSys Deca electronic timer module for LC1D09-D38, LC1D40A-D80A, LC1D80-D150 (3P) contactors
LA4DWB Schneider Electric
LA4DWB
Schneider Electric
TeSys Deca low signal interface module, for control of contactors LC
LAD4CM Schneider Electric
LAD4CM
Schneider Electric
TeSys D mechanical interlock, for contactors LC1D40A-D80A and LC1DT60A-DT80A
LAD4RC3E Schneider Electric
LAD4RC3E
Schneider Electric
TeSys D suppressor module, for LC1D40A-D80A, LC1DT60A-DT80A contactors
LAD4RC3G Schneider Electric
LAD4RC3G
Schneider Electric
TeSys D suppressor module, for LC1D40A-D80A, LC1DT60A-DT80A contactors
LAD4RC3U Schneider Electric
LAD4RC3U
Schneider Electric
TeSys D suppressor module, for LC1D40A-D80A, LC1DT60A-DT80A contactors
LAD6K10F Schneider Electric
LAD6K10F
Schneider Electric
TeSys Deca mechanical latch block, for LC1D09-D80A, LC1DT20-DT80A contactors and CAD control relays (except devices with low consumption coils)
LAD8N02 Schneider Electric
LAD8N02
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD8N11 Schneider Electric
LAD8N11
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD8N20 Schneider Electric
LAD8N20
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD9ET1S Schneider Electric
LAD9ET1S
Schneider Electric
TeSys D safety protective cover, for preventing access to the moving contact carrier
LAD9R3 Schneider Electric
LAD9R3
Schneider Electric
TeSys D kit for reversing contactors assembly, for 3-pole contactors LC1D40A-D80A
LADN02 Schneider Electric
LADN02
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN04 Schneider Electric
LADN04
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN11 Schneider Electric
LADN11
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN13 Schneider Electric
LADN13
Schneider Electric
Schneider Electric's TeSys Deca auxiliary contact block offers 1NO+3NC instantaneous contacts rated up to 10A 690V AC. It is suitable for safety applications and can be easily mounted on front by clip-on.
LADN20 Schneider Electric
LADN20
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN22 Schneider Electric
LADN22
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN31 Schneider Electric
LADN31
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN40 Schneider Electric
LADN40
Schneider Electric
The TeSys Deca auxiliary contact block provides four normally open (NO) contacts for integration into control circuits with LC1D09 to LC1D150 contactors.
LADR0 Schneider Electric
LADR0
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADR2 Schneider Electric
LADR2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADR4 Schneider Electric
LADR4
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADS2 Schneider Electric
LADS2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT0 Schneider Electric
LADT0
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT2 Schneider Electric
LADT2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT4 Schneider Electric
LADT4
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD

Approfondimenti sul mercato

AutomaINSIGHTS cruscotto di analisi

Ottenere dati analitici e di mercato in tempo reale per ottimizzare le decisioni di acquisto di questo componente e di prodotti simili

  • Dati sulla disponibilità di magazzino in tempo reale da oltre 700 distributori MRO in Europa e negli Stati Uniti.
  • Analisi dei prezzi per condizione (nuovo, usato, ricondizionato) con prezzi mediani di mercato
  • Monitoraggio della disponibilità dei componenti critici per prevenire i tempi di inattività della produzione
  • Ottimizzazione dell'inventario in base alle tendenze di approvvigionamento del mercato
Inizia