Schneider Electric
LADT2
1 / 6
Descrizione
Attivo maturo
TeSys D contactors have a variety of accessories that can be mount to them. This on delay timer attachemnt mounts on the top of contactor with rating from 9 amp to 150 amp. The one NO and one NC contacts can be used in the control circuit. TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for any type of application. TeSys D contactors offer quick simple setup, while maintaining a compact size. Contactors have both horsepower and Kw motor rating for international acceptance. An extennsive line of accessories makes it easy to meet the requirements of most applications. These contactors have UL, CSA, GOST, RINA, BV, CCC, DNV, GL, LROS certifications.- Country of Origin
- FR
- Part Number
- LADT2
- Tariff Code
- 85365080
- EAN
- 3389110385892
- UNSPSC
- 39121529
€30.58
net€33.98
Spedizione da:
€25.00
1
Metodi di pagamento:
- Migliore offerta da:
- Fornitore Automa.Net di fiducia
- Disponibilità:
- 7 pz.DisponibileAggiornato il: 22-11-2024
- Garanzia:
- 12 mesi
- Consegna stimata:
- 27-29 novembre a Regno Unito
- Condizione:
- Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Informazioni sulla spedizione
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia
Environment
- Ambient Air Temperature For Operation
- -40-70 °C
- Ip Degree Of Protection
- IP20 conforming to IEC 60529
- Ambient Air Temperature For Storage
- -60-80 °C
- Environmental Characteristic
- normal environment
- Protective Treatment
- TH IEC 60068
- Operating Altitude
- 9842.52 ft (3000 m)
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110702
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: Cancer - www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- N/A
- Eu Rohs Directive
- Compliant with Exemptions
Complementary
- Non-Overlap Time
- 1.5 ms on de-energisation no overlap between NC and NO contact || 1.5 ms on energisation no overlap between NC and NO contact
- Permissible Short-Time Rating
- 100 A 60 °C 1 s || 120 A 60 °C 500 ms || 140 A 60 °C 100 ms
- Minimum Switching Current
- 5 mA
- Height
- 48 mm
- Protection Type
- gG fuse 10 A
- Insulation Resistance
- > 10 MOhm
- Irms Rated Making Capacity
- 140 A at <= 690 V AC conforming to IEC 60947-5-1 || 250 A at <= 690 V DC conforming to IEC 60947-5-1
- Connections - Terminals
- screw clamp terminals 1 1-2.5 mm²flexible with cable end || screw clamp terminals 1 1-2.5 mm²flexible without cable end || screw clamp terminals 2 1-2.5 mm²flexible with cable end || screw clamp terminals 2 1-2.5 mm²flexible without cable end || screw clamp terminals 1 1-2.5 mm²rigid || screw clamp terminals 2 1-2.5 mm²rigid || screw clamp terminals
- Minimum Switching Voltage
- 17 V
- Tightening Torque
- 1.7 N.m flat Ø 6 mm || 1.7 N.m Philips No 2 || 1.7 N.m pozidriv No 2
- Mechanical Durability
- 5 Mcycles
- Color
- dark grey
- Width
- 44 mm
- Depth
- 61 mm
Specifications
- Product Certifications
- IECEE CB Scheme || UL || CSA || CCC || EAC || UKCA
- [Ith] Conventional Free Air Thermal Current
- 10 A (at 60 °C)
- Standards
- CSA C22.2 No 60947-5-1 || GB/T 14048.5 || EN/IEC 60947-5-1
- Timer Type
- on delay
- [Ue] Rated Operational Voltage
- 690 V AC 25...400 Hz
- Range Compatibility
- TeSys Deca CAD || TeSys Deca LC1D || TeSys F LC1F || TeSys F CR1F
- Product Or Component Type
- time delay auxiliary contact block
- Product Name
- TeSys Deca
- Range
- TeSys || TeSys Deca
- Mounting Location
- front
- Pole Contact Composition
- 1 NO + 1 NC
- [Ui] Rated Insulation Voltage
- 690 V IEC 60947-5-1 || 600 V UL 60947-5-1 || 600 V CSA C22.2 No 60947-5-1
- [Ie] Rated Operational Current
- 6 A at 120 V AC-15 || 1.04 A at 690 V AC-15 || 0.55 A at 125 V DC-13 || 0.1 A at 600 V DC-13
- Time Delay Range
- 1...30 s
- Auxiliary Contacts Operation
- time delay