1 / 1
thumbnail

Descrizione

Attivo maturo
TeSys F contactor, 4 poles (4NO), 315A/690V AC-1, for non-inductive load applications. Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Country of Origin
CZ
Part Number
LC1F2254
Tariff Code
85364900
EAN
3389110230888
UNSPSC
39121529
Metodi di pagamento:
Migliore offerta da:
JOFornitore Automa.Net di fiducia
Disponibilità:
2 pz.
Disponibile
Aggiornato il: 27-08-2024
Consegna stimata:
Su richiesta
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Un totale di 14 Parts In-Stock da 4 Distributors
Consegna da:
JO
JO
SK
SK
GB
GB
DE
DE
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Offerte Disponibili (3)

LC1F2254 product image
Schneider Electric

LC1F2254

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
10 pz.
Disponibile
Aggiornato il: 08-11-2024
Offerta da:
SKFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
Garanzia:
12 mesi
1
LC1F2254 product image
Schneider Electric

LC1F2254

Condizione:
Nuove eccedenze
Disponibile:
1 pz.
Disponibile
Aggiornato il: 21-10-2024
Offerta da:
GBFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
LC1F2254 product image
Schneider Electric

LC1F2254

Condizione:
Nuove eccedenze
Disponibile:
1 pz.
Disponibile
Aggiornato il: 08-11-2024
Offerta da:
DEFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
Garanzia:
12 mesi
1
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
€493.83

Environment

Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed5 Gn, 5...300 Hz || shocks contactor open7 Gn for 1/2 sine wave (11 ms) || shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Ambient Air Temperature For Operation
-5-55 °C
Height
197 mm
Net Weight
5.55 kg
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH
Ip Degree Of Protection
IP20 front face with shrouds IEC 60529 || IP20 front face with shrouds VDE 0106
Operating Altitude
9842.52 ft (3000 m) without derating
Width
208.5 mm
Depth
181 mm
Permissible Ambient Air Temperature Around The Device
-40-70 °C

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP080208EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI100418
Eu Rohs Directive
Compliant with Exemptions

Complementary

Product Certifications
UL || LROS (Lloyds register of shipping) || BV || CB || ABS || DNV || CSA || RMRoS || RINA || UKCA
Power Dissipation Per Pole
32 W AC-1
Average Impedance
0.32 mOhm - Ith 315 A 50 Hz
Control Circuit Voltage Limits
operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil || drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil || operational: 0.85...1.1 Uc DC with LX4 coil || drop-out: 0.15...0.2 Uc DC with LX4 coil || operational: 85...275 V AC 50/60 Hz with LXE coil || drop-out: 0...60 V AC 50/60 Hz with LXE coil || operational: 85...418 V DC with LXE coil || drop-out: 0...45 V DC with LXE coil
[Ith] Conventional Free Air Thermal Current
315 A (at 40 °C)
Standards
JIS C8201-4-1 || IEC 60947-4-1 || IEC 60947-1 || EN 60947-4-1 || EN 60947-1
[Uc] Control Circuit Voltage
24...575 V AC 40...400 Hz with LX9 coil || 24...460 V DC with LX4 coil || 100...250 V AC 50/60 Hz with LXE coil || 100...380 V DC with LXE coil
Mounting Support
plate
Rated Breaking Capacity
1800 A conforming to IEC 60947-4-1
Irms Rated Making Capacity
2250 A conforming to IEC 60947-4-1
Associated Fuse Rating
315 A gG at <= 440 V
[Uimp] Rated Impulse Withstand Voltage
8 kV
Connections - Terminals
power circuit lugs-ring terminals 1 185-185 mm² || power circuit connector 1 185-185 mm² || power circuit bar 2 32 x 4 mm || power circuit bolted connection || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm² || control circuit screw clamp terminals 2 1-4 mm² || control circuit screw clamp terminals 1.0 0.2-2.5 mm²flexible without cable end || control circuit screw clamp terminals 1.0 0.25-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1.0 0.2-2.5 mm²solid without cable end
Inrush Power In Va
950-1180 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil || 737-902 VA (at 20 °C)with LX4 coil || 280-310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil || 270-320 VA (at 20 °C)with LXE coil
Maximum Operating Rate
2400 cyc/h 55 °C
Operating Time
35 ms closing with LX9 coil || 130 ms opening with LX9 coil || 30...40 ms closing with LX4 coil || 30...50 ms opening with LX4 coil || 40...80 ms closing with LXE coil || 6...54 ms opening with LXE coil
Tightening Torque
power circuit 35 N.m || control circuit 1.2 N.m || control circuit 0.6 N.m
Mechanical Durability
10 Mcycles
Compatibility Code
LC1F
Hold-In Power Consumption In Va
8.9-10.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil || 4.13-5.07 VA (at 20 °C)with LX4 coil || 4.5-7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil || 2.5-4.0 VA (at 20 °C)with LXE coil
Overvoltage Category
III
[Ui] Rated Insulation Voltage
1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
[Icw] Rated Short-Time Withstand Current
1800 A 40 °C - 10 s || 1000 A 40 °C - 30 s || 850 A 40 °C - 1 min || 560 A 40 °C - 3 min || 440 A 40 °C - 10 min
Heat Dissipation
8-9.8 W || 2.2-2.5 W

Specifications

[Ue] Rated Operational Voltage
<= 690 V AC 50/60 Hz || <= 460 V DC
Contactor Application
resistive load
Product Or Component Type
contactor
Product Name
TeSys F
Range
TeSys
Pole Contact Composition
4 NO
[Ie] Rated Operational Current
315 A 40 °C) <= 440 V AC-1
Utilisation Category
AC-1
Poles Description
4P
Device Short Name
LC1F

Modelli CAD

traceparts
traceparts
Scaricare