Schneider Electric
SR3PACKBD
Modular discovery packs, Zelio Logic, smart relay discovery pack, 10 I/O, 24 V DC
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Un totale di 42 Parts In-Stock da 16 Distributors
Condizioni del prodotto:
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
€89.74
Additional Information
- Part Number
- SR3PACKBD
- UNSPSC
- 39122331
- Tariff Code
- 8536410060
- Country of Origin
- FR
Environment
- Product Certifications
- GL || UL || CSA || GOST || C-tick
- Standards
- IEC 60068-2-27 Ea || IEC 60068-2-6 Fc || IEC 61000-4-3 || IEC 61000-4-6 level 3 || IEC 61000-4-11 || IEC 61000-4-5 || IEC 61000-4-2 level 3 || IEC 61000-4-12 || IEC 61000-4-4 level 3
- Disturbance Radiated/Conducted
- class B EN 55022-11 group 1
- Ambient Air Temperature For Operation
- -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55 °C IEC 60068-2-1 and IEC 60068-2-2
- Immunity To Microbreaks
- 1 ms
- Environmental Characteristic
- EMC directive IEC 61000-6-2 || EMC directive IEC 61000-6-3 || EMC directive IEC 61000-6-4 || EMC directive IEC 61131-2 zone B || low voltage directive IEC 61131-2
- Ip Degree Of Protection
- IP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel)
- Pollution Degree
- 2 IEC 61131-2
- Ambient Air Temperature For Storage
- -40-70 °C
- Relative Humidity
- 95-95 % without condensation or dripping water
- Maximum Altitude Transport
- 3048 m
- Operating Altitude
- 6561.68 ft (2000 m)
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP060406EN
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI0604006EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Complementary
- Contacts Type And Composition
- NO relay output
- Input Impedance
- 12 kOhm IB...IG used as analogue input circuit || 12 kOhm IB...IG used as discrete input circuit || 7.4 kOhm I1...IA and IH...IR discrete input circuit
- Discrete Input Type
- resistive
- Analogue Input Range
- 0...24 V || 0...10 V
- Conversion Error
- +/- 5 % 25 °C analogue input circuit || +/- 6.2 % 55 °C analogue input circuit
- Output Thermal Current
- 8 A for all 4 outputs relay output
- Number Or Control Scheme Lines
- 120-120 ladder || 0-200 FBD
- Lsb Value
- 39 mV analogue input circuit
- Discrete Input Voltage
- 24 V DC
- Backup Time
- 10 years 25 °C
- Clock Drift
- 12 min/year 0-55 °C || 6 s/month 25-25 °C
- Analogue Input Type
- common mode
- Discrete Input Current
- 4 mA
- Current State 1 Guaranteed
- >= 1.2 mA IB...IG used as discrete input circuit) || >= 2.2 mA I1...IA and IH...IR discrete input circuit)
- Response Time
- 10 ms from state 0 to state 1)relay output || 5 ms from state 1 to state 0)relay output
- Clock
- with
- Power Dissipation In W
- 3 W without extension || 8 W with extensions
- Local Display
- with
- Net Weight
- 0.7 kg
- Input/Output Number
- 10
- Voltage State 0 Guaranteed
- <= 5 V I1...IA and IH...IR discrete input circuit || <= 5 V IB...IG used as discrete input circuit || <= 5 V
- Output Voltage Limits
- 24...250 V AC relay output) || 5...30 V DC relay output)
- Conversion Time
- smart relay cycle time analogue input circuit
- Electrical Durability
- AC-12 500000 cycles 230 V, 1.5 A relay output IEC 60947-5-1 || AC-15 500000 cycles 230 V, 0.9 A relay output IEC 60947-5-1 || DC-12 500000 cycles 24 V, 1.5 A relay output IEC 60947-5-1 || DC-13 500000 cycles 24 V, 0.6 A relay output IEC 60947-5-1
- Analogue Input Number
- 4
- Connections - Terminals
- screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid || screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid || screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end
- Voltage State 1 Guaranteed
- >= 15 V I1...IA and IH...IR discrete input circuit || >= 15 V IB...IG used as discrete input circuit
- Input Compatibility
- 3-wire proximity sensors PNP discrete input
- Current State 0 Guaranteed
- <= 0.5 mA IB...IG used as discrete input circuit) || <= 0.75 mA I1...IA and IH...IR discrete input circuit)
- Supply Voltage Limits
- 19.2-30 V
- Operating Distance
- 10 m between stations, with screened cable (sensor not isolated) analogue input circuit
- Overvoltage Category
- III IEC 60664-1
- Mechanical Durability
- 10000000 cycles relay output
- Maximum Supply Current
- 100 mA with extensions) || 100 mA without extension)
- Tightening Torque
- 0.5 N.m
- Temperature Probe Type
- NTC 10k 25 °C || NTC 1000k 25 °C || KTY81 210/220/221/222/250 || Pt 500
- Switching Capacity In Ma
- >= 10 mA 12 V relay output)
- Analogue Input Resolution
- 8 bits
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
- Operating Rate In Hz
- 0.1 Hz at Ie)relay output || 10 Hz no load)relay output
- Counting Frequency
- 1 kHz discrete input
- Cycle Time
- 6-90 ms
- Kit Composition
- SR3B101BD || cable PC SR2USB01 for connection to PC
- Reverse Polarity Protection
- with
- Maximum Permissible Voltage
- 30 V analogue input circuit
- Repeat Accuracy
- +/- 2 % 55 °C analogue input circuit
- [Us] Rated Supply Voltage
- 24 V
- Checks
- program memory on each power up
Specifications
- Range Of Product
- Zelio Logic
- Number Of Outputs
- 4 relay
- Product Or Component Type
- modular discovery packs
- Discrete Input Number
- 6 IEC 61131-2 Type 1