Hai bisogno di ulteriori informazioni?

Chiamaci al:+48 17 778 34 19

Schneider Electric TPRBCPFB

Bus coupler, TeSys island, 24VDC, 3A, Profibus DP

1 / 1
Schneider Electric TPRBCPFB Bus coupler, TeSys island, 24VDC, 3A, Profibus DP — Accessori generali
Immagine di catalogo del produttore

Descrizione del prodotto

Ciclo di vita:
TeSys island bus coupler, point of connection between a TeSys island configuration (group of starters) and an automation system over PROFIBUS DP. It performs all functions for the application (TeSys avatars), selectable and configurable through SoMove or MachineExpert. For diagnostics and maintenance of the TeSys island, a web server (OMT) is embedded. To be supplied externally by 24V DC, it provides one D-Sub port for PROFIBUS DP, one RJ45 service port over Ethernet, one micro SD card port, and a port for the internal bus interconnecting the modules of the island. Mounting on DIN rail, together with the other modules of the TeSys island configuration, the bus coupler is the module on the most left position. Multi standards certified (IEC, UL, CSA, CCC, EAC), cybersecurity Achilles Level 2 certified, Green Premium compliant (RoHS/REACh).
Invia la richiesta
Metodi di pagamento:

Dettagli dell'offerta

Migliore offerta da:
Fornitore di fiducia — Romania, membro dal 2023, 1–4 dipendenti
Disponibilità:
1 pz.
Su richiesta
Aggiornato il: 22-08-2026
Condizione:
Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Il venditore è responsabile della spedizione del prodotto e della fatturazione

Specifiche tecniche

Ambient Air Temperature For Operation
-10-60 °C
Shock Resistance
15 gn 11 ms) IEC 60068-2-27
Vibration Resistance
1.5 mm peak to peak 3-13 Hz) IEC 60068-2-6 || 1 gn 13-200 Hz) IEC 60068-2-6
Electromagnetic Compatibility
electrostatic discharge, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || radiated RF fields, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 || communication: fast transients immunity test, level 3, 1 kV, conforming to EN/IEC 61000-4-4 || power supply: fast transients immunity test, level 3, 2 kV, conforming to EN/IEC 61000-4-4 || communication: surge immunity test (common mode), level 3, 1 kV, conforming to EN/IEC 61000-4-5 || power supply: surge immunity test (common mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5
Pollution Degree
2
Ambient Air Temperature For Storage
-25-70 °C

Offerte Disponibili

(3)
TPRBCPFB Schneider Electric, Accessori generali

Schneider Electric

Disponibile:
0 pz.
Su richiesta
Aggiornato il: 04-09-2026
Offerta da:
Fornitore di fiducia — Germania, membro dal 2024
TPRBCPFB Schneider Electric, Accessori generali

Schneider Electric

Disponibile:
0 pz.
Su richiesta
Aggiornato il: 05-09-2026
Offerta da:
Fornitore di fiducia — Italia, membro dal 2021, 10–19 dipendenti
Garanzia:
12 mesi

Accedi alla nostra piattaforma per trovare altre offerte

Registratevi ora per esplorare 36 mln di offerte da fornitori verificati in tutto il mondo.

  • Confrontare le offerte a livello globale
  • Contatto diretto con i fornitori
  • RFQ, preventivi e ordini
  • Ricerca della distinta base
RegistratiDisponibile una prova gratuita di 14 giorni
Offerta con tempi di consegna del produttore
Direttamente dal produttore, con tempi di consegna confermati, prevedibili e completamente trasparenti.
Preventivo

Documenti

Scheda tecnica

Scheda tecnica per Schneider Electric TPRBCPFB, incluse specifiche e caratteristiche.

Scarica scheda dati
TracePartsTraceParts

Modelli CAD

Modello CAD 3D e disegni tecnici, pronti per il tuo software di progettazione.

Scarica modello CAD

Prodotti compatibili

TPRAN2X1 Schneider Electric
TPRAN2X1
Schneider Electric
The TeSys Island Analog IO Module is a versatile component for advanced control functions, offering two analog inputs and one analog output. It's compatible with the TPRBC bus coupler and can be mounted on a DIN rail along with other modules.
TPRDG4X2 Schneider Electric
TPRDG4X2
Schneider Electric
TeSys island digital IO module, 4 digital inputs 24V DC, 2 digital outputs 24V DC
TPRPM009 Schneider Electric
TPRPM009
Schneider Electric
Power module for TeSys island, featuring three poles and a rated operational current of 9A at 690V.
TPRPM038 Schneider Electric
TPRPM038
Schneider Electric
TeSys island power module, 3 poles, 38A/690V.
TPRPM080 Schneider Electric
TPRPM080
Schneider Electric
TeSys island power module, 3 poles, 80A/690V
TPRSM001 Schneider Electric
TPRSM001
Schneider Electric
TeSys island SIL interface module, 2 inputs, 1 output
TPRSS009 Schneider Electric
TPRSS009
Schneider Electric
TeSys island direct SIL starter, 3 poles, 9A/690V
TPRSS025 Schneider Electric
TPRSS025
Schneider Electric
TeSys island direct SIL starter, 3 poles, 25A/690V
TPRSS038 Schneider Electric
TPRSS038
Schneider Electric
TeSys island direct SIL starter, 3 poles, 38A/690V
TPRSS065 Schneider Electric
TPRSS065
Schneider Electric
The TeSys island SIL motor starter offers robust control, protection, and monitoring for loads up to 65A and motors up to 30kW@400V / 40hp@480V. It conforms to IEC 61508 safety standards when used with a TPRSM001 module and an external safety device.
TPRSS080 Schneider Electric
TPRSS080
Schneider Electric
TeSys island direct SIL starter, 3 poles, 80A/690V
TPRST009 Schneider Electric
TPRST009
Schneider Electric
The TeSys Island direct starter is a versatile motor control solution that provides robust protection and monitoring for loads up to 9A and motors up to 4kW@400V / 5hp@480V.
TPRST025 Schneider Electric
TPRST025
Schneider Electric
TeSys island direct starter, 3 poles, 25A/690V
TPRST038 Schneider Electric
TPRST038
Schneider Electric
The TeSys Island motor starter is a robust solution for controlling and protecting loads up to 38A and motors up to 18.5kW@400V / 20hp@480V.
TPRST065 Schneider Electric
TPRST065
Schneider Electric
The TeSys Island motor starter is a robust solution designed for controlling and protecting loads up to 65A and motors up to 30kW@400V / 40hp@480V.
TPRST080 Schneider Electric
TPRST080
Schneider Electric
TeSys island direct starter, 3 poles, 80A/690V
TPRVM001 Schneider Electric
TPRVM001
Schneider Electric
TeSys island voltage interface module, 100-690V / 47-63Hz

Prodotti correlati

LRD10L Schneider Electric
LRD10L
Schneider Electric
TeSys LRD thermal overload relay, 6A/690V, thermal setting range 4-6A, tripping class 20, for protection of 3-phase motors 2
ZBY2366 Schneider Electric
ZBY2366
Schneider Electric
A customizable legend holder for Harmony XB4 and XB5 push buttons and pilot lights.
XB5DSB Schneider Electric
XB5DSB
Schneider Electric
The Harmony XB5 mechanical hour counter provides a visual indication of operational hours with a 5-digit display, operating on both 12–24V AC/DC power.
LVCT00302S Schneider Electric
LVCT00302S
Schneider Electric
This low-voltage split-core current transformer is ideal for retrofit applications with Schneider Electric energy meters.
XB5DTB23 Schneider Electric
XB5DTB23
Schneider Electric
A panel-mounted monofunction timer with a time delay range of 3 to 60 seconds and a 24V DC input.
NSYMM86 Schneider Electric
NSYMM86
Schneider Electric
Plain mounting plate for Spacial CRN, S3D, S3X, PLM
RXG23BDPV Schneider Electric
RXG23BDPV
Schneider Electric
The Harmony Electromechanical Relay is a pre-assembled relay designed for industrial applications. It offers 5A capacity and 2 contacts with an integrated LED indicator.
LR2K0306 Schneider Electric
LR2K0306
Schneider Electric
TeSys LRK thermal overload relay, 1
LRD3361 Schneider Electric
LRD3361
Schneider Electric
TeSys LRD thermal overload relay, 70A/1000V, thermal setting range 55-70A, tripping class 10A, for protection of 3-phase motors 37kW@400V
A9MEM3150 Schneider Electric
A9MEM3150
Schneider Electric
The Acti9 iEM3000 series energy meters offer an attractive range of three-phase DIN rail-mounted energy meters with an LCD display
A9MEM3455 Schneider Electric
A9MEM3455
Schneider Electric
The Acti9 iEM3000 series energy meters provide a range of three-phase DIN rail-mounted devices with an LCD display and local signaling features.
LR3D086 Schneider Electric
LR3D086
Schneider Electric
TeSys LRD thermal overload relay, 4A/690V, thermal setting range 2

Approfondimenti sul mercato

AutomaINSIGHTS cruscotto di analisi

Ottenere dati analitici e di mercato in tempo reale per ottimizzare le decisioni di acquisto di questo componente e di prodotti simili

  • Dati sulla disponibilità di magazzino in tempo reale da oltre 700 distributori MRO in Europa e negli Stati Uniti.
  • Analisi dei prezzi per condizione (nuovo, usato, ricondizionato) con prezzi mediani di mercato
  • Monitoraggio della disponibilità dei componenti critici per prevenire i tempi di inattività della produzione
  • Ottimizzazione dell'inventario in base alle tendenze di approvvigionamento del mercato
Inizia

Altre categorie