Schneider Electric
VW3A4711
1 / 1
Descrizione
Attivo maturo
- Country of Origin
- CN
- Part Number
- VW3A4711
- Tariff Code
- 85480090
- EAN
- 3606481164780
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Environment
- Standards
- IEC 61800-3
- Ambient Air Temperature For Operation
- -10-50 °C without current derating) || 50-60 °C with current derating 1.5 % per °C)
- Ambient Air Temperature For Storage
- -40-70 °C
- Relative Humidity
- 5-95 % without condensation IEC 61800-5-1
- Ip Degree Of Protection
- IP20mounting side by side
- Operating Altitude
- 0...3280.84 ft (0...1000 m) without current derating || 3280.84...13123.36 ft (1000...4000 m) with current derating 1 % per 100 m
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- China Rohs Regulation
- X
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Specifications
- Range Of Product
- Altivar
- Product Compatibility
- variable speed drive ATV34015 kW, 380...480 V || variable speed drive ATV34011 kW, 380...480 V
- Product Or Component Type
- EMC input filter
- Phase
- three phase
- Mounting Location
- at variable speed drive side
- Product Specific Application
- radio interference input filter
- Line Rated Current
- 50 A
- Range Compatibility
- Altivar Machine ATV340
- Thermal Losses
- 8 W
Complementary
- Mechanical Robustness
- shocks class 3M4 IEC 60721-3-3 || vibrations class 3M4 IEC 60721-3-3
- Height
- 285 mm
- Tolerance
- 10 %
- Maximum Motor Cable Length
- 100 m shielded motor cable 4 kHz IEC 61800-3 category C3, 380...480 V || 50 m shielded motor cable 4 kHz IEC 61800-3 category C2, 380...480 V
- Net Weight
- 5.2 kg
- Earth Leakage Current
- 7.6 mA 400 V 50 Hz TN
- Network Rated Voltage
- 380-480 V
- Electrical Connection
- terminal 16 mm² AWG 4
- Width
- 90 mm
- Depth
- 170 mm
Modelli CAD
traceparts