Schneider Electric
XCKJ10511
1 / 6
Descrizione
Attivo maturo
This XCKJ industrial format (EN 50041) limit switch has a thermoplastic roller lever and a Zamak body. This limit switch has a robust Zamak body and head, a modular design allowing easier maintenance and a industrial CENELEC EN50041 form A format. It is IP66 and IK07 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947.-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508, BV, EAC standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.- Country of Origin
- ID
- Part Number
- XCKJ10511
- Tariff Code
- 85365080
- EAN
- 3389110646023
- UNSPSC
- 39122213
€39.00
netSpedizione Gratuita!1
Metodi di pagamento:
- Migliore offerta da:
- Fornitore Automa.Net di fiducia
- Disponibilità:
- 1 pz.DisponibileAggiornato il: 09-11-2024
- Garanzia:
- 12 mesi
- Consegna stimata:
- 12-25 novembre a Regno Unito
- Condizione:
- Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Informazioni sulla spedizione
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia
Specifications
- Movement Of Operating Head
- rotary
- Range Of Product
- Telemecanique Limit switches XC Standard
- Fixing Mode
- by the body
- Type Of Operator
- spring return roller lever thermoplastic
- Sensor Design
- form A CENELEC EN 50041
- Cable Entry
- 1 entry tapped for Pg 13.5 cable gland 9-12 mm
- Product Or Component Type
- limit switch
- Head Material
- zamak
- Material
- metal
- Head Type
- rotary head
- Type Of Approach
- lateral approach, 1 or 2 programmable direction
- Series Name
- standard format
- Contacts Type And Composition
- 1 NC + 1 NO
- Body Type
- fixed
- Contact Operation
- snap action
- Body Material
- zamak
- Device Short Name
- XCKJ
- Number Of Poles
- 2
Contractual warranty
- Warranty
- 18 months
Complementary
- Height
- 77-77 mm
- Terminals Description Iso N°1
- (13-14)NO || (21-22)NC
- Short-Circuit Protection
- 10 A cartridge fuse gG
- Electrical Connection
- screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
- Number Of Steps
- 1
- [Ithe] Conventional Enclosed Thermal Current
- 10 A
- Net Weight
- 0.48 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60664 || 6 kV IEC 60947-1
- Switch Actuation
- by 30° cam
- [Ui] Rated Insulation Voltage
- 300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
- Electrical Durability
- 5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
- Positive Opening
- with
- Contacts Insulation Form
- Zb
- [Ie] Rated Operational Current
- 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
- Positive Opening Minimum Torque
- 0.5 N.m
- Mechanical Durability
- 30000000 cycles
- Maximum Actuation Speed
- 1.5 m/s
- Width
- 40 mm
- Depth
- 44 mm
- Minimum Torque For Tripping
- 0.25 N.m
- Maximum Resistance Across Terminals
- 25 MOhm IEC 60255-7 category 3
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110614EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- CCC || CSA || UL
- Ik Degree Of Protection
- IK07 EN 50102
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- CSA C22.2 No 14 || IEC 60947-5-1 || CENELEC EN 50041 || IEC 60204-1 || EN 60204-1 || EN 60947-5-1 || UL 508
- Shock Resistance
- 50 gn 11 ms IEC 60068-2-27
- Vibration Resistance
- 25 gn 10-500 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP66 conforming to IEC 60529
- Ambient Air Temperature For Storage
- -40-70 °C
- Overvoltage Category
- class I IEC 61140 || class I NF C 20-030
- Protective Treatment
- TH