1 / 1
thumbnail

Descrizione

Attivo maturo
The Preventa XCS range is an offer of safety switches. They are designed for controlling the safe opening and interlocking of guards and covers. It is a coded magnetic system with dedicated transmitter. 3 approach directions. It features a rectangular plastic boby, 88mm x 25mm x 13mm, and a 5m long pre-cabled electrical connection . 2-pole 1 NC + 1 NO (staggered). It can reach category 4 Safety Level with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1. It can reach PL equal e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1. It can reach SIL 3, with the appropriate monitoring system and correctly wired, conforming to EN/IEC 61508.
Country of Origin
FR
Part Number
XCSDMP5905
Tariff Code
85365080
EAN
3389119012997
UNSPSC
39122213
£228.11
net
1
Metodi di pagamento:
Migliore offerta da:
PLFornitore Automa.Net di fiducia
Disponibilità:
1 pz.
Disponibile
Aggiornato il: 17-05-2024
Consegna stimata:
Su richiesta
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Un totale di 13 Parts In-Stock da 4 Distributors
Consegna da:
PL
PL
GB
GB
DE
DE
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Offerte Disponibili (3)

XCSDMP5905 product image
Schneider Electric

XCSDMP5905

Condizione:
Nuove eccedenze
Disponibile:
1 pz.
Disponibile
Aggiornato il: 21-10-2024
Offerta da:
GBFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
XCSDMP5905 product image
Schneider Electric

XCSDMP5905

Condizione:
Nuove eccedenze
Disponibile:
1 pz.
Disponibile
Aggiornato il: 08-11-2024
Offerta da:
DEFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
Garanzia:
12 mesi
1
XCSDMP5905 product image
Schneider Electric

XCSDMP5905

Condizione:
Nuove eccedenze
Disponibile:
10 pz.
Disponibile
Aggiornato il: 09-11-2024
Offerta da:
PLFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
Invia una richiesta di prezzo

Specifications

Range Of Product
Telemecanique Safety switches XCS
[Ue] Rated Operational Voltage
24 V DC
Cable Length
5 m
Product Or Component Type
coded magnetic switch
Component Name
XCSDMP
Design
rectangular, standard
Material
plastic
Size
88 x 25 x 13 mm
Contacts Type And Composition
1 NC + 1 NO
Contact Operation
staggered
Electrical Connection
pre-cabled
Cable Composition
4 x 0.25 mm²
Approach Directions
3 directions
[Ui] Rated Insulation Voltage
100 V DC
Number Of Poles
2

Contractual warranty

Warranty
18 months

Complementary

Maximum [Ie] Rated Operational Current
100 mA
Height
88 mm
Switching Frequency
150 Hz
Short-Circuit Protection
500 mA external cartridge fuse gG (gl)
Switching Capacity In Ma
0.1...100 mA
[Sar] Assured Tripping Distance
20 mm
Contacts Material
rhodium
Insulation Resistance
1000 MOhm
Resistance Across Terminals
10 Ohm
Net Weight
0.18 kg
[Uimp] Rated Impulse Withstand Voltage
2.5 kV EN/IEC 60947-5-1
Maximum Switching Voltage
100 V DC
[Sa] Assured Operating Distance
8 mm
Cable Material
PVC
Breaking Capacity
10 VA
Safety Reliability Data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure Material
thermoplastic PBT
Width
25 mm
Depth
13 mm
Electrical Durability
1200000 cycles
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || UL
Ambient Air Temperature For Operation
-25-85 °C
Standards
ISO 14119 || EN/IEC 60947-5-1 || EN/IEC 60204-1 || CSA C22.2 No 14 || EN/ISO 12100 || UL 508
Shock Resistance
30 gn 11 ms IEC 60068-2-27
Vibration Resistance
10 gn 10-150 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529
Ambient Air Temperature For Storage
-40-85 °C
Electrical Shock Protection Class
class II EN/IEC 61140
Maximum Sensitivity To Magnetic Fields
0.3 mT
Protective Treatment
TH