- Height
- 161-161 mm
- [Ui] Rated Insulation Voltage
- 300 VUL 508 || 300 VCSA C22.2 No 14 || 500 V 3)EN/IEC 60947-1
- Short-Circuit Protection
- 10 A cartridge fuse gG (gl)
- Positive Opening
- with NC contact
- Positive Opening Minimum Torque
- 0.25 N.m
- Mechanical Durability
- 1000000 cycles
- [Ithe] Conventional Enclosed Thermal Current
- 10 A
- Safety Reliability Data
- B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
- Enclosure Material
- polyamide PA66 fibre glass impregnated
- Lever Material
- stainless steel
- Contact Code Designation
- A300, AC-15 (Ue = 120 V, Ie = 6 A)EN/IEC 60947-5-1 || A300, AC-15 (Ue = 240 V, Ie = 3 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 125 V, Ie = 0.55 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 250 V, Ie = 0.27 A)EN/IEC 60947-5-1
- Tripping Angle
- 5 °
- Width
- 30 mm
- Depth
- 30 mm
- Cable Outer Diameter
- 7-10 mm
- Minimum Torque For Tripping
- 0.1 N.m
- Net Weight
- 0.095 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV EN/IEC 60947-5-1
- Maximum Resistance Across Terminals
- 30 mOhm EN/IEC 60947-5-4
- Safety Level
- can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508