Siemens

6GK7343-1GX31-0XE0

ETHERNET, CONTROLLER, CP 343-1, S7-300
6GK7343-1GX31-0XE0
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
€829.17
1
Metodi di pagamento:
Un totale di 134 Parts In-Stock da 39 Distributors

Descrizione

AttivoConforme a RoHS
SIMATIC NET CP 343-1 ADVANCED; FOR CONNECTING SIMATIC S7-300 CPU TO IND. ETHERNET; PROFINET IO CONTROLLER AND/OR IO-DEVICE; RT AND RT AND IRT IRT, MRP, PROFINET CBA; TCP/IP; ISO,UDP,S7-COM,S5-KOMP. COM., (SEND/RECEIVE) W. FETCH/WRITE WITH AND WITHOUT RFC 1006, MULTICAST DIAGNOSIS EXTENSION, SNMP, DHCP, FTP CLIENT/SERVER, E-MAIL, GIGABIT-SS1X RJ45 (10/100/1000) PROFINET-SS 2X RJ45(10/100MBIT) PROFINET CBA; SECURITY (FIREWALL/VPN); PROFIENERGY

Additional Information

Part Number
6GK7343-1GX31-0XE0
UPC
887621032623
Tariff Code
8517620090
Country of Origin
DE
ETIM
Group Code : EG000024
Group Description : PLC's
Class Description : PLC communication module
Class Code : EC001423
Version : 7

Specifications

Country of Origin
DE
Width
80 mm
Depth
120 mm
Height
125 mm
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Number of interfaces PROFINET
2
SIL according to IEC 61508
None
Type of data transmission
Other
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces parallel
0
Transmission rate
1000000000 kBit/s
Supporting protocol for TCP/IP
true
Number of HW-interfaces serial TTY
0
Explosion safety category for gas
None
Explosion safety category for dust
None
Supporting protocol for PROFINET IO
true
Supporting protocol for PROFINET CBA
true
Performance level acc. EN ISO 13849-1
None
Number of HW-interfaces industrial Ethernet
3