Weidmuller
1335030000
UR20-PF-O-1DI-SIL
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
€236.13
Additional Information
- Part Number
- 1335030000
General Data
- Air humidity (operation)
- 10% to 95%, non-condensing as per DIN EN 61131-2
- Air humidity (storage)
- 10% to 95%, non-condensing as per DIN EN 61131-2
- Air humidity (transport)
- 10% to 95%, non-condensing as per DIN EN 61131-2
- Air pressure (operation)
- ≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2
- Air pressure (storage)
- 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
- Air pressure (transport)
- 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
- Pollution severity
- 2
- Shock
- 15 g over 11 ms, half sinus wave, acc. to IEC 60068-2-27
- Surge voltage category
- II
- Test voltage
- 500 V
- UL 94 flammability rating
- V-0
- Vibration resistance
- 5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6
Approvals
- Approvals
- CULUS, CULUSEX, DEMKOATEX, EAC, FUSAFETY, IECEXULD, KOREANCERT, TUEV
- ROHS
- Conform
- UL File Number Search
- E141197
Dimensions And Weights
- Width
- 11.5 mm
- Width (inches)
- 0.453 inch
- Height
- 120 mm
- Height (inches)
- 4.724 inch
- Depth
- 76 mm
- Depth (inches)
- 2.992 inch
- Mounting dimension - height
- 128 mm
- Net weight
- 109 g
Connection Data
- Type of connection
- PUSH IN
- Wire connection cross section, finely stranded, max.
- 1.5 mm²
- Wire connection cross-section, finely stranded, min.
- 0.14 mm²
- Wire cross-section, finely stranded, max. (AWG)
- AWG 16
- Wire cross-section, finely stranded, min. (AWG)
- AWG 26
- Wire cross-section, solid, max.
- 1.5 mm²
- Wire cross-section, solid, max. (AWG)
- AWG 16
- Wire cross-section, solid, min.
- 0.14 mm²
- Wire cross-section, solid, min. (AWG)
- AWG 26
Safety-Related Data
- MTTF
- 100 Years
- Proportion of safety-related outages (SFF)
- 98 %
- Safety category
- SIL 3
Classifications
- ETIM 6.0
- EC001600
- ETIM 7.0
- EC001600
- EClass 9.0
- 27-24-26-10
- EClass 9.1
- 27-24-26-10
- EClass 10.0
- 27-24-26-10
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
System Data
- Field bus protocol
- CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus/TCP, PROFINET IRT, PROFIBUS DP-V1, POWERLINK
- Galvanic isolation
- Yes, between field and system bus
- Interface
- u-remote system bus
- Module type
- Safe power-feed module
- Transmission speed of system bus, max.
- 48 Mbit
Temperatures
- Operating temperature, max.
- 60 °C
- Operating temperature, min.
- -20 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -40 °C
- Operating temperature
- -20 °C ... +60 °C
- Storage temperature
- -40 °C ... +85 °C
Power Supply
- Current consumption from I
- 35 mA
- Feed current for I
- 8,050 mA
- Supply voltage for outputs
- 24 V DC +20 %/ -15 %
- Supply voltage system and inputs
- 24 V DC +20 %/ -15 %
- Voltage supply
- 24 V DC +20 %/ -15 %, via the system bus