Wyszukiwarka produktów
Kategorie
Powrót do:Czujniki i urządzenia pomiaroweFiltry
VPA2MNA
VP03EM
VTI2
LFFS-021.0
LFP2000-G1NMB
LFV200-XXHCLIPM
LFV200-XXSGAIPM
LRS510-10-34-LI2UPN8-H1141
LRS510-10-51-2UPN8-H1141
LRS510-10-51-LI2UPN8-H1141
LRS510-10-57-2UPN8-H1141
LRS510-10-57-LI2UPN8-H1141
LRS510-10-69-2UPN8-H1141
LS-534-0000-LIU24PN8X-H1181
Level Sensor, With Analog Output and 4 × Switching Outputs, , Multiple output signals: one system for both level detection and continuous level monitoring, Low maintenance and quick commissioning without calibration, High flexibility due to cutable probe, Compact, rotatable display housing ensures easy installation, Small inactive areas, ideal for small containers, Process temperature to 212 °F, Process pressure up to 145 psi, Coaxial tubes available for non-metallic tanks, IO-Link 1.1, , 12…30 VDC, 1x analog output 4… 20 mA/0… 10 V (automatic switchover depending on load), 1x transistor output (PNP) or IO-Link, 3x transistor output (PNP/NPN switchable)
Level Sensor, With Analog Output and 4 × Switching Outputs, , Multiple output signals: one system for both level detection and continuous level monitoring, Low maintenance and quick commissioning without calibration, High flexibility due to cutable probe, Compact, rotatable display housing ensures easy installation, Small inactive areas, ideal for small containers, Process temperature to 212 °F, Process pressure up to 145 psi, Coaxial tubes available for non-metallic tanks, IO-Link 1.1, , 12…30 VDC, 1x analog output 4… 20 mA/0… 10 V (automatic switchover depending on load), 1x transistor output (PNP) or IO-Link, 3x transistor output (PNP/NPN switchable)
LS-551-0000-LIU22PN8X-H1151
Level Sensor, With Analog Output and 2 × Switching Outputs, , Multiple output signals: one system for both level detection and continuous level monitoring, Low maintenance and quick commissioning without calibration, High flexibility due to cutable probe, Compact, rotatable display housing ensures easy installation, Small inactive areas, ideal for small containers, Process temperature to 212 °F, Process pressure up to 145 psi, Coaxial tubes available for non-metallic tanks, IO-Link 1.1, , 12…30 VDC, 1 × analog output 4… 20 mA/0… 10 V (automatic switchover depending on load), 2 × PNP/IO-Link or PNP/NPN transistor outputs, each switchable
Level Sensor, With Analog Output and 2 × Switching Outputs, , Multiple output signals: one system for both level detection and continuous level monitoring, Low maintenance and quick commissioning without calibration, High flexibility due to cutable probe, Compact, rotatable display housing ensures easy installation, Small inactive areas, ideal for small containers, Process temperature to 212 °F, Process pressure up to 145 psi, Coaxial tubes available for non-metallic tanks, IO-Link 1.1, , 12…30 VDC, 1 × analog output 4… 20 mA/0… 10 V (automatic switchover depending on load), 2 × PNP/IO-Link or PNP/NPN transistor outputs, each switchable
LS-551-0500-LIU22PN8X-H1151
Level Sensor, With Analog Output and 2 × Switching Outputs, , Multiple output signals: one system for both level detection and continuous level monitoring, Low maintenance and quick commissioning without calibration, High flexibility due to cutable probe, Compact, rotatable display housing ensures easy installation, Small inactive areas, ideal for small containers, Process temperature to 212 °F, Process pressure up to 145 psi, Coaxial tubes available for non-metallic tanks, IO-Link 1.1, , 12…30 VDC, 1 × analog output 4… 20 mA/0… 10 V (automatic switchover depending on load), 2 × PNP/IO-Link or PNP/NPN transistor outputs, each switchable, Process connection G3/4 male thread, Probe length 500 mm, "
Level Sensor, With Analog Output and 2 × Switching Outputs, , Multiple output signals: one system for both level detection and continuous level monitoring, Low maintenance and quick commissioning without calibration, High flexibility due to cutable probe, Compact, rotatable display housing ensures easy installation, Small inactive areas, ideal for small containers, Process temperature to 212 °F, Process pressure up to 145 psi, Coaxial tubes available for non-metallic tanks, IO-Link 1.1, , 12…30 VDC, 1 × analog output 4… 20 mA/0… 10 V (automatic switchover depending on load), 2 × PNP/IO-Link or PNP/NPN transistor outputs, each switchable, Process connection G3/4 male thread, Probe length 500 mm, "
LS-551-0500-LIU24PN8X-H1181
Level Sensor, With Analog Output and 4 × Switching Outputs, , Multiple output signals: one system for both level detection and continuous level monitoring, Low maintenance and quick commissioning without calibration, High flexibility due to cutable probe, Compact, rotatable display housing ensures easy installation, Small inactive areas, ideal for small containers, Process temperature to 212 °F, Process pressure up to 145 psi, Coaxial tubes available for non-metallic tanks, IO-Link 1.1, , 12…30 VDC, 1x analog output 4… 20 mA/0… 10 V (automatic switchover depending on load), 1x transistor output (PNP) or IO-Link, 3x transistor output (PNP/NPN switchable), Process connection G3/4 male thread, Probe length 500 mm, "
Level Sensor, With Analog Output and 4 × Switching Outputs, , Multiple output signals: one system for both level detection and continuous level monitoring, Low maintenance and quick commissioning without calibration, High flexibility due to cutable probe, Compact, rotatable display housing ensures easy installation, Small inactive areas, ideal for small containers, Process temperature to 212 °F, Process pressure up to 145 psi, Coaxial tubes available for non-metallic tanks, IO-Link 1.1, , 12…30 VDC, 1x analog output 4… 20 mA/0… 10 V (automatic switchover depending on load), 1x transistor output (PNP) or IO-Link, 3x transistor output (PNP/NPN switchable), Process connection G3/4 male thread, Probe length 500 mm, "
LS-551-0700-LIU22PN8X-H1151
Level Sensor, With Analog Output and 2 × Switching Outputs, , Multiple output signals: one system for both level detection and continuous level monitoring, Low maintenance and quick commissioning without calibration, High flexibility due to cutable probe, Compact, rotatable display housing ensures easy installation, Small inactive areas, ideal for small containers, Process temperature to 212 °F, Process pressure up to 145 psi, Coaxial tubes available for non-metallic tanks, IO-Link 1.1, , 12…30 VDC, 1 × analog output 4… 20 mA/0… 10 V (automatic switchover depending on load), 2 × PNP/IO-Link or PNP/NPN transistor outputs, each switchable, Process connection G3/4 male thread, Probe length 700 mm, "
Level Sensor, With Analog Output and 2 × Switching Outputs, , Multiple output signals: one system for both level detection and continuous level monitoring, Low maintenance and quick commissioning without calibration, High flexibility due to cutable probe, Compact, rotatable display housing ensures easy installation, Small inactive areas, ideal for small containers, Process temperature to 212 °F, Process pressure up to 145 psi, Coaxial tubes available for non-metallic tanks, IO-Link 1.1, , 12…30 VDC, 1 × analog output 4… 20 mA/0… 10 V (automatic switchover depending on load), 2 × PNP/IO-Link or PNP/NPN transistor outputs, each switchable, Process connection G3/4 male thread, Probe length 700 mm, "
LUS211-40-34-LI2UPN8-H1141
Ultrasonic Sensor, Level Control, Max. range 400 mm, 4-digit, 2-colored, 12-segment display, rotatable by 180°, Housing is rotatable after mounting the process connection, 3/4 NPT process connection, Blind zone: 0.5 cm, Range: 40 cm, Resolution: 0.5 mm, Aperture angle of sonic cone: ±15 °, 1 × switching output, PNP/NPN, 1 × analog output, 4…20 mA / 0…10 V / additional switching output, PNP/NPN, NO/NC programmable, Transmission of process value and parametrization via IO-link, "
Ultrasonic Sensor, Level Control, Max. range 400 mm, 4-digit, 2-colored, 12-segment display, rotatable by 180°, Housing is rotatable after mounting the process connection, 3/4 NPT process connection, Blind zone: 0.5 cm, Range: 40 cm, Resolution: 0.5 mm, Aperture angle of sonic cone: ±15 °, 1 × switching output, PNP/NPN, 1 × analog output, 4…20 mA / 0…10 V / additional switching output, PNP/NPN, NO/NC programmable, Transmission of process value and parametrization via IO-link, "