Appleton Group
JBEP4N6M2015G
1 / 1
Opis
Appleton™ increased safety ATX™ JBEP Series fiberglass reinforced polyester terminal junction boxes for electrical and power applications are factory drilled and equipped. They are ideal for lighting and distribution applications in Zone 1 and 2, 21 and 22. These enclosures feature pillar (live mantle clamping), miniature or screw terminals for use with armored and un-armored cable. The JBEP Series of power junction boxes are designed for motor and power distribution applications in Zone 1 and 2, 21 and 22. These enclosures can be supplied with 16mm² to 240mm² terminals in multiple configurations for use with armored and un-armored cables.- Part Number
- JBEP4N6M2015G
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Specifications
- Standard Materials
- Static resistant carbon filled fiberglass reinforced polyester (FRP) enclosure with stainless steel hardware. Silicone gasket for sizes 85 x 85, 120 x 120 and EPDM (ethylene propylene diene monomer rubber) gasket for other sizes
- Options
- External hinges on specific sizes, removable glands plates, nameplates, mounting pan, terminal rail, and inside pocket for document are available. See catalog pages for details. Consult factory for custom drilling and assembly requirements
- Zones 1 and 2 Temperature Class
- T6 for Ta ≤ +40 °C (+104 °F) and T5 for Ta ≤ +60 °C (+140 °F)
- Zones 21 and 22 Surface Temperature
- T60 °C (T140 °F) for Ta ≤ +40 °C (+104 °F), T90 °C (+194 °F) for Ta ≤ +60 °C (+140 °F)
- Ambient Temperatures
- -55 °C ≤ Ta ≤ +60 °C (-67 °F ≤ Ta ≤ +140 °F)
- Ambient Temperatures: Glands
- Type 757: -60 °C to +100 °C (-40 °F to +212 °F). Type EEXe: -20 °C to +55 °C (-4 °F to +131 °F). Type E1FX, E2FX, E1FW, E2FW, T3, A2F: -60 °C to +130 °C (-76 °F to +266 °F). Type PX, PX2K: -60 °C to +10
- Ambient Temperatures: Terminals
- Type WDU, WFF: -50 °C to +120 °C (-58 °F to +248 °F). Type SAK, AKZ: -50 °C to +100 °C (-58 °F to +212 °F)
- Ambient Temperatures: Drain/Breather
- Type DBE: -50 °C to +85 °C (-58 °F to +185 °F)
- Ambient Temperatures: Close Up Plug
- Type Bve: -40 °C to +55 °C (-40 °F to +131 °F)
Certifications and Compliances
- NEC/CEC Certifications and Compliances
- Class I, Zone 1, AEx e IIC, T5 or T6; Ex e IIC, T5 or T6; IP66
- ATEX/IECEx Certifications and Compliances
- Zone 1 and 2 - 21 and 22; Ex II 2 GD; IP66; IK10
- Other Certifications
- EURASEC and INMETRO
Inne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne