Fluke Networks

OFP2-100-S

1 / 5
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail

Opis

Designed for Enterprise, Datacenter, Outside Plant and PON Fiber As fiber networks evolve, the need to test in more locations has increased. OTDRs are now needed for: FTTx Enterprise OSP PON POLAN Many OTDRs designed for fiber troubleshooting are designed for carrier and contain cumbersome and complicated features. The OptiFiber Pro OTDR family is the first class of OTDRs that is built with features and usability for both the enterprise network engineers, and cable installers working in both enterprise and OSP environments.
Part Number
OFP2-100-S
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Poproś o wycenę, a prześlemy Ci informacje o dostępności i cenie.

Key OptiFiber Pro HDR Specification

Wavelengths
1490 nm +/- 20 nm || 1550 nm +/- 20 nm || 1310 nm +/- 25 nm || 1625 nm +/- 20 nm
Compatible fiber types
Singlemode
OTDR Port Connector
Cleanable APC ferrule with removable SC adapter
Event dead zone 1
0. 7 m (typical)
Attenuation dead zone2
4m (typical)
PON dead zone3
30 m (typical)
Max distance range setting
260 km
Dynamic range 4, 5
1310 nm: 42 dB (typical || 1490 nm: 41 dB (typical) || 1625 nm: 40 dB (typical) || 1550 nm: 41 dB (typical) || 1310 nm: 42 dB (typical)
Reflectance range4
-14 to -70 dB (typical)
Sampling resolution
3 cm to 2 m
Sampling points
Up to 129000
Pulse widths (nominal)
5, 10, 30, 50, 100, 300, 500, 1000, 3000, 5000, 10000, 20000 ns
Distance uncertainty
+/-(1 + 0. 0005*distance + 0. 5*resolution)
Linearity
± 0. 03 dB/dB
Reflectance uncertainty
±2 dB
Test Time (per wavelength)
Best resolution setting: 5 to 180 seconds/wavelength || Auto PON setting: 10 seconds/wavelength (typical) || Quick test setting: 3 seconds/wavelength (typical) || Manual PON setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength || Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength || Auto setting: 5 seconds/wavelength (typical)
Laser Classification
Class 1 CDRH Complies to EN 60825-2, 3rd Edition
Calibration Period
1 year

Additional key specifications

Magnification
~ 200X with OptiFiber Pro Display
Light source
Blue LED
Power source
Versiv mainframe
Field of View (FOV)
Horizontal: 425 µm || Vertical: 320 µm
Minimum detectable particle size
0. 5 µm
Dimensions
Mainframe with module and battery: 2. 625 in x 5. 25 in x 11. 0 in ( 6. 67 cm x 13. 33 cm x 27. 94 cm)
Weight
Mainframe with module and battery: 3 lbs, 5 oz (1. 28 kg)
Temperature range
Operating: 32°F to 122°F (0 °C to +50 °C) || Storage: -4°F to +158°F (-20°C to +70°C)
Certifications
CE (when used with the mainframe)
On/Off control
Mechanical switch and a button on the touch screen
Output power
316 µW (-5 dBm) = peak power = 1. 0 mW (0 dBm)
Operating wavelength
650 nm nominal
Spectral width (RMS)
±3 nm
Output modes
Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter
2. 5 mm universal
Laser safety (classification)
Class II CDRH Complies to EN 60825-2
Battery
Lithium ion battery pack, 7. 2 volts
Battery life
Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Integrated Wi-Fi
Meets IEEE 802. 11 a/b/g/n; dual band (2. 4 GHz and 5 GHz)
Tester Off
Four hours to charge from 10% to 90% capacity
Tester On
Six hours to charge from 10% to 90% capacity with the tester on
Operating temperature*
-10ºC to 45ºC
Storage Temperature
-10ºC to +60ºC
Operating altitude
4,000 m (13123 ft) || 3200 m (10,500 ft) with ac adapter
Storage altitude
12,000 m
EMC
EN 61326-1

Key OptiFiber Pro OTDR specifications

Wavelengths
850 nm +/- 10 nm || 1300 nm +35/-15 nm || 1550 nm +/- 30 nm || 1310 nm +/- 25 nm
Compatible fiber types
50/125 µm || 62. 5/125 µm || Singlemode
Event dead zone 1
1550 nm: 0. 6 m typical || 1310 nm: 0. 6 m typical || 850 nm: 0. 5 m typical || 1300 nm: 0. 7 m typical
Attenuation dead zone 2
1310 nm: 3. 6 m typical || 1300 nm: 4. 5 m typical || 850 nm: 2. 5 m typical || 1550 nm: 3. 7 m typical
Dynamic range 3, 5, 6
1300 nm: 30 dB typical || 850 nm: 28 dB typical || 1550 nm: 30 dB typical || 1310 nm: 32 dB typical
Max distance range setting
40 km || MM: 40 km || SM: 130 km || 130 km
Distance measurement range 4, 5, 7, 8, 9, 10
1310 nm: 80 km || 850 nm: 9 km || 1550 nm: 130 km || 1300 nm: 35 km
Reflectance range 4, 5
1300 nm: -14 dB to -62 dB (typical) || 1310 nm: -14 dB to -65 dB (typical) || 1310 nm: -14 dB to -65dB (typical) || 1550 nm: -14 dB to -65 dB (typical) || 850 nm: -14 dB to -57 dB (typical)
Sample resolution
3 cm to 400 cm
Pulse widths (nominal)
1300 nm: 3, 5, 20, 40, 200, 1000 ns || 1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns || 850 nm: 3, 5, 20, 40, 200 ns
Test time (per wavelength)
|| Best resolution setting: 5 to 180 sec || Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec || Auto setting: 10 sec (typical) || Quick test setting: 2 sec (typical) || MM - 2 sec (typical), MM - 180 sec (max) || Manual setting: || -3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec || DataCenter OTDR setting: 1 sec (typical at 850 nm), 7 sec (max) || DataCenter OTDR setting: || SM - 10 sec (typical), SM - 180 sec (max) || Auto setting: 5 sec (typical) || FaultMap setting: 10 sec (typical), 180 sec (max) || FaultMap setting: || Best resolution setting: 2 to 180 sec || MM – 1 sec (typical at 850 nm) MM – 7 sec (max) || MM – 2 sec (typical) || Quick test setting: || DataCenter OTDR setting: 20 sec (typical), 40 sec (max) || MM – 2 to 180 sec M || SM – 10 sec (typical) || SM – 5 sec (typical) || FaultMap setting: 2 sec (typical), 180 sec (max) || Quick test setting: 5 sec (typical) || MM – 5 sec (typical) || SM – 5 to 180 sec || Best resolution setting: || SM – 20 sec (typical) SM – 40 sec (max) || Auto setting: