Fluke Networks
OFP2-100-S
1 / 5
Opis
Designed for Enterprise, Datacenter, Outside Plant and PON Fiber As fiber networks evolve, the need to test in more locations has increased. OTDRs are now needed for: FTTx Enterprise OSP PON POLAN Many OTDRs designed for fiber troubleshooting are designed for carrier and contain cumbersome and complicated features. The OptiFiber Pro OTDR family is the first class of OTDRs that is built with features and usability for both the enterprise network engineers, and cable installers working in both enterprise and OSP environments.- Part Number
- OFP2-100-S
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Key OptiFiber Pro HDR Specification
- Wavelengths
- 1490 nm +/- 20 nm || 1550 nm +/- 20 nm || 1310 nm +/- 25 nm || 1625 nm +/- 20 nm
- Compatible fiber types
- Singlemode
- OTDR Port Connector
- Cleanable APC ferrule with removable SC adapter
- Event dead zone 1
- 0. 7 m (typical)
- Attenuation dead zone2
- 4m (typical)
- PON dead zone3
- 30 m (typical)
- Max distance range setting
- 260 km
- Dynamic range 4, 5
- 1310 nm: 42 dB (typical || 1490 nm: 41 dB (typical) || 1625 nm: 40 dB (typical) || 1550 nm: 41 dB (typical) || 1310 nm: 42 dB (typical)
- Reflectance range4
- -14 to -70 dB (typical)
- Sampling resolution
- 3 cm to 2 m
- Sampling points
- Up to 129000
- Pulse widths (nominal)
- 5, 10, 30, 50, 100, 300, 500, 1000, 3000, 5000, 10000, 20000 ns
- Distance uncertainty
- +/-(1 + 0. 0005*distance + 0. 5*resolution)
- Linearity
- ± 0. 03 dB/dB
- Reflectance uncertainty
- ±2 dB
- Test Time (per wavelength)
- Best resolution setting: 5 to 180 seconds/wavelength || Auto PON setting: 10 seconds/wavelength (typical) || Quick test setting: 3 seconds/wavelength (typical) || Manual PON setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength || Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength || Auto setting: 5 seconds/wavelength (typical)
- Laser Classification
- Class 1 CDRH Complies to EN 60825-2, 3rd Edition
- Calibration Period
- 1 year
Additional key specifications
- Magnification
- ~ 200X with OptiFiber Pro Display
- Light source
- Blue LED
- Power source
- Versiv mainframe
- Field of View (FOV)
- Horizontal: 425 µm || Vertical: 320 µm
- Minimum detectable particle size
- 0. 5 µm
- Dimensions
- Mainframe with module and battery: 2. 625 in x 5. 25 in x 11. 0 in ( 6. 67 cm x 13. 33 cm x 27. 94 cm)
- Weight
- Mainframe with module and battery: 3 lbs, 5 oz (1. 28 kg)
- Temperature range
- Operating: 32°F to 122°F (0 °C to +50 °C) || Storage: -4°F to +158°F (-20°C to +70°C)
- Certifications
- CE (when used with the mainframe)
- On/Off control
- Mechanical switch and a button on the touch screen
- Output power
- 316 µW (-5 dBm) = peak power = 1. 0 mW (0 dBm)
- Operating wavelength
- 650 nm nominal
- Spectral width (RMS)
- ±3 nm
- Output modes
- Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
- Connector adapter
- 2. 5 mm universal
- Laser safety (classification)
- Class II CDRH Complies to EN 60825-2
- Battery
- Lithium ion battery pack, 7. 2 volts
- Battery life
- Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
- Integrated Wi-Fi
- Meets IEEE 802. 11 a/b/g/n; dual band (2. 4 GHz and 5 GHz)
- Tester Off
- Four hours to charge from 10% to 90% capacity
- Tester On
- Six hours to charge from 10% to 90% capacity with the tester on
- Operating temperature*
- -10ºC to 45ºC
- Storage Temperature
- -10ºC to +60ºC
- Operating altitude
- 4,000 m (13123 ft) || 3200 m (10,500 ft) with ac adapter
- Storage altitude
- 12,000 m
- EMC
- EN 61326-1
Key OptiFiber Pro OTDR specifications
- Wavelengths
- 850 nm +/- 10 nm || 1300 nm +35/-15 nm || 1550 nm +/- 30 nm || 1310 nm +/- 25 nm
- Compatible fiber types
- 50/125 µm || 62. 5/125 µm || Singlemode
- Event dead zone 1
- 1550 nm: 0. 6 m typical || 1310 nm: 0. 6 m typical || 850 nm: 0. 5 m typical || 1300 nm: 0. 7 m typical
- Attenuation dead zone 2
- 1310 nm: 3. 6 m typical || 1300 nm: 4. 5 m typical || 850 nm: 2. 5 m typical || 1550 nm: 3. 7 m typical
- Dynamic range 3, 5, 6
- 1300 nm: 30 dB typical || 850 nm: 28 dB typical || 1550 nm: 30 dB typical || 1310 nm: 32 dB typical
- Max distance range setting
- 40 km || MM: 40 km || SM: 130 km || 130 km
- Distance measurement range 4, 5, 7, 8, 9, 10
- 1310 nm: 80 km || 850 nm: 9 km || 1550 nm: 130 km || 1300 nm: 35 km
- Reflectance range 4, 5
- 1300 nm: -14 dB to -62 dB (typical) || 1310 nm: -14 dB to -65 dB (typical) || 1310 nm: -14 dB to -65dB (typical) || 1550 nm: -14 dB to -65 dB (typical) || 850 nm: -14 dB to -57 dB (typical)
- Sample resolution
- 3 cm to 400 cm
- Pulse widths (nominal)
- 1300 nm: 3, 5, 20, 40, 200, 1000 ns || 1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns || 850 nm: 3, 5, 20, 40, 200 ns
- Test time (per wavelength)
- || Best resolution setting: 5 to 180 sec || Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec || Auto setting: 10 sec (typical) || Quick test setting: 2 sec (typical) || MM - 2 sec (typical), MM - 180 sec (max) || Manual setting: || -3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec || DataCenter OTDR setting: 1 sec (typical at 850 nm), 7 sec (max) || DataCenter OTDR setting: || SM - 10 sec (typical), SM - 180 sec (max) || Auto setting: 5 sec (typical) || FaultMap setting: 10 sec (typical), 180 sec (max) || FaultMap setting: || Best resolution setting: 2 to 180 sec || MM – 1 sec (typical at 850 nm) MM – 7 sec (max) || MM – 2 sec (typical) || Quick test setting: || DataCenter OTDR setting: 20 sec (typical), 40 sec (max) || MM – 2 to 180 sec M || SM – 10 sec (typical) || SM – 5 sec (typical) || FaultMap setting: 2 sec (typical), 180 sec (max) || Quick test setting: 5 sec (typical) || MM – 5 sec (typical) || SM – 5 to 180 sec || Best resolution setting: || SM – 20 sec (typical) SM – 40 sec (max) || Auto setting:
Inne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne