ABB
1SBH136001R2231
1 / 1
Descripción
NFZ contactor relays are used for switching auxiliary and control circuits. NFZ contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...250 V 50/60 Hz or 12...250 V DC. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change NFZ contactor relays allow direct control by PLC-output ≥ 24 V DC 500 mA and obtain a reduced holding coil consumption. NFZ contactor relays withstand short voltage dips and voltage sags (SEMI F47-0706 compliance) between 24...250 V 50/60 Hz NFZ contactor relays have built-in surge protection and do not require additional surge suppressors - Poles: 4-pole contactor relays (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and including the "Mechanically Linked" symbol on the contactor relay side) - Control Circuit: AC or DC operated - Accessories: a wide range of Accessories is available.- Country of Origin
- FR
- Part Number
- 1SBH136001R2231
- Tariff Code
- 85364900
- EAN
- 3471523101821
- UNSPSC
- 39121529
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Contactor relay
- Class Code : EC000196
- Version : 7
€28.01
net€31.13
Envío desde:
€40.00
1
Métodos de pago:
- Mejor oferta de:
- Proveedor de confianza de Automa.Net
- Disponibilidad:
- 1 piezaEn stockActualizado en: 19-11-2024
- Garantía:
- 24 meses
- Entrega Estimada:
- 28 noviembre - 02 diciembre a Reino Unido
- Condición:
- Nuevos excedentes
Nuevos excedentes - Un artículo nuevo, sin usar, sin daños y sin garantía del fabricante. El artículo puede venir sin embalaje original o en embalaje de reemplazo. Si se proporciona, es posible que la caja haya sido abierta.
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía
Dimensions
- Product Net Width
- 45 mm
- Product Net Depth / Length
- 77 mm
- Product Net Height
- 86 mm
- Product Net Weight
- 0.31 kg
Technical
- Number of Auxiliary Contacts NO
- 3
- Number of Auxiliary Contacts NC
- 1
- Standards
- IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13
- Rated Operational Voltage
- Auxiliary Circuit 690 V
- Rated Frequency (f)
- Auxiliary Circuit 50 / 60 HzControl Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-5-1, Θ = 40 °C 16 A
- Rated Operational Current AC-15 (Ie)
- (500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A
- Rated Short-time Withstand Current Low Voltage (Icw)
- for 0.1 s 140 Afor 1 s 100 A
- Maximum Electrical Switching Frequency
- (AC-15) 1200 cycles per hour(DC-13) 900 cycles per hour
- Rated Operational Current DC-13 (Ie)
- (24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W(400 V) 0.15 A / 60 W(500 V) 0.13 A / 65 W(600 V) 0.1 A / 60 W
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-5-1 690 Vacc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp)
- 6 kV
- Maximum Mechanical Switching Frequency
- 6000 cycles per hour
- Rated Control Circuit Voltage (Uc)
- 50 Hz 48 ... 130 V60 Hz 48 ... 130 VDC Operation 48 ... 130 V
- Operate Time
- Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms
- Mounting on DIN Rail
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Mounting by Screws (not supplied)
- 2 x M4 screws placed diagonally
- Connecting Capacity Auxiliary Circuit
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
- Connecting Capacity Control Circuit
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
- Wire Stripping Length
- Auxiliary Circuit 10 mmControl Circuit 10 mm
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
- Terminal Type
- Screw Terminals
Classifications
- Object Classification Code
- K
- ETIM 4
- EC000196 - Contactor relay
- ETIM 5
- EC000196 - Contactor relay
- EClass
- V11.0 : 27371001
- IDEA Granular Category Code (IGCC)
- 4763 >> Power contactor, DC switching
- E-Number (Finland)
- 3706412
- E-Number (Sweden)
- 3211460
Environmental
- Ambient Air Temperature
- Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... 70 °C
- Climatic Withstand
- Category B according to IEC 60947-1 Annex Q
- Maximum Operating Altitude Permissible
- Without Derating 3000 m
- Resistance to Vibrations acc. to IEC 60068-2-6
- 5 ... 300 Hz 4 g closed position / 2 g open position
- Resistance to Shock acc. to IEC 60068-2-27
- Closed, Shock Direction: B1 25 gOpen, Shock Direction: B1 5 gShock Direction: A 30 gShock Direction: B2 15 gShock Direction: C1 25 gShock Direction: C2 25 g
- RoHS Status
- Following EU Directive 2011/65/EU
Technical UL/CSA
- Connecting Capacity Auxiliary Circuit UL/CSA
- Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
- Tightening Torque UL/CSA
- Auxiliary Circuit 11 in·lbControl Circuit 11 in·lb
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85364900
Otras categorías
ActuadoresBloquesCables, tuberías y manguerasCompresoresControlAcoplamientos y AccesoriosCilindros y PistonesElectrónicaFiltrosHVACPCs industriales y HMIsIluminaciónTécnica linealMotoresFuente de alimentaciónTransmisión de energíaBombas y VálvulasEnergías renovablesRobóticaSellos, anillos y conectoresSensores y dispositivos de mediciónHerramientas y AccesoriosCNCOtros