- Non-Overlap Time
- 1.5 ms on energisation between NC and NO contacts || 1.5 ms on de-energisation between NC and NO contacts
- Minimum Switching Current
- 5 mA for control circuit
- Power Dissipation Per Pole
- 9.6 W AC-1 || 3.7 W AC-3e || 3.7 W AC-3
- Auxiliary Contact Composition
- 1 NO + 1 NC
- [Ith] Conventional Free Air Thermal Current
- 80 A (at 60 °C) for power circuit || 10 A (at 60 °C) for control circuit
- Control Circuit Voltage Limits
- 0.75...1.25 Uc -40-60 °C operational DC || 1...1.25 Uc 60-70 °C operational DC || 0.1...0.3 Uc -40-70 °C drop-out DC
- Mounting Support
- plate
- Control Circuit Type
- DC wide range
- Safety Reliability Level
- B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 || B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
- Hold-In Power Consumption In W
- 7.4-7.4 W 20 °C
- Insulation Resistance
- > 10 MOhm for control circuit
- Rated Breaking Capacity
- 900 A at 440 V for power circuit conforming to IEC 60947
- Irms Rated Making Capacity
- 900 A at 440 V DC for power circuit conforming to IEC 60947 || 900 A at 440 V for power circuit conforming to IEC 60947 || 250 A DC for control circuit conforming to IEC 60947-5-1
- Associated Fuse Rating
- 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1 || 10 A gG for control circuit conforming to IEC 60947-5-1
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV IEC 60947
- Pole Contact Composition
- 3 NO
- Connections - Terminals
- control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: screw terminals 1 2.5-25 mm² - cable stiffness: rigid || power circuit: screw terminals 2 2.5-16 mm² - cable stiffness: rigid without cable end || power circuit: screw terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end || power circuit: screw terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end || power circuit: screw terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end || power circuit: screw terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid
- Coil Technology
- built-in bidirectional peak limiting diode suppressor
- Time Constant
- 34 ms
- Operating Time
- 50 ms closing || 20 ms opening
- Minimum Switching Voltage
- 17 V for control circuit
- Maximum Operating Rate
- 3600 cyc/h 60 °C
- Tightening Torque
- control circuit 1.7 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm || control circuit 1.7 N.m screw clamp terminal pozidriv No 2 || control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm
- Mechanical Durability
- 10000000 cycles
- Inrush Power In W
- 19-19 W 20 °C)
- Auxiliary Contacts Type
- mirror contact 1 NC IEC 60947-4-1 || mechanically linked 1 NO + 1 NC IEC 60947-5-1
- Compatibility Code
- LC1D
- Overvoltage Category
- III
- Maximum Horse Power Rating
- 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors || 15 hp at 200/208 V AC 60 Hz for 3 phase motors || 15 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 40 hp at 575/600 V AC 60 Hz for 3 phase motors || 3 hp at 115 V AC 60 Hz for 1 phase motors
- Motor Power Kw
- 25 kW at 415 V AC 50 Hz (AC-3) || 30 kW at 440 V AC 50 Hz (AC-3) || 30 kW at 500 V AC 50 Hz (AC-3) || 33 kW at 660...690 V AC 50 Hz (AC-3) || 15 kW at 220...230 V AC 50 Hz (AC-3) || 11 kW at 400 V AC 50 Hz (AC-4) || 30 kW at 1000 V AC 50 Hz (AC-3) || 22 kW at 380...400 V AC 50 Hz (AC-3e) || 25 kW at 415 V AC 50 Hz (AC-3e) || 30 kW at 440 V AC 50 Hz (AC-3e) || 30 kW at 500 V AC 50 Hz (AC-3e) || 33 kW at 660...690 V AC 50 Hz (AC-3e) || 15 kW at 220...230 V AC 50 Hz (AC-3e) || 30 kW at 1000 V AC 50 Hz (AC-3e) || 22 kW at 380...400 V AC 50 Hz (AC-3)
- [Ui] Rated Insulation Voltage
- control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL IEC 60947-1 || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1 || power circuit 1000 V CSA IEC 60947-4-1 || control circuit 600 V CSA
- Rated Operational Power In W
- 48 W 24 V DC-13 3000000 cycles - control circuit || 96 W 24 V DC-13 1000000 cycles - control circuit || 14 W 24 V DC-13 10000000 cycles - control circuit
- Protective Cover
- with