1 / 5
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail

Descripción

Activo maduro
This XCKM classic format limit switch has a metal end plunger and a Zamak body. This limit switch has a robust Zamak body, 3 cable entries, a modular design allowing easier maintenance and a classic format. It is IP66 and IK05 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508, BV standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.
Country of Origin
ID
Part Number
XCKM110
Tariff Code
85365080
EAN
3389110646429
UNSPSC
39122213
€37.67
net
1
Métodos de pago:
Mejor oferta de:
GBProveedor de confianza de Automa.Net
Disponibilidad:
3 piezas
En stock
Actualizado en: 12-11-2024
Entrega Estimada:
Bajo pedido
Condición:
Nuevo Precintado de Fábrica
Nuevo Precintado de Fábrica - Un artículo completamente nuevo, sin usar, sin abrir, sin daños, en su embalaje original sellado por el fabricante.
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Specifications

Movement Of Operating Head
linear
Range Of Product
Telemecanique Limit switches XC Standard
Fixing Mode
by the body
Type Of Operator
spring return plunger metal
Cable Entry
3 entries tapped for Pg 11 cable gland
Product Or Component Type
limit switch
Material
metal
Head Type
plunger head
Type Of Approach
vertical approach, 1 direction
Series Name
standard format
Contacts Type And Composition
1 NC + 1 NO
Body Type
fixed
Contact Operation
snap action
Body Material
zamak
Device Short Name
XCKM
Number Of Poles
2

Contractual warranty

Warranty
18 months

Complementary

Height
64-64 mm
Terminals Description Iso N°1
(21-22)NC || (13-14)NO
Short-Circuit Protection
10 A cartridge fuse gG
Minimum Actuation Speed
0.01 m/min
Electrical Connection
screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
Number Of Steps
1
Net Weight
0.25 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60664 || 6 kV IEC 60947-1
Switch Actuation
on end
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
Electrical Durability
5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 24 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 48 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Positive Opening Minimum Force
45 N
Positive Opening
with
Contacts Insulation Form
Zb
Mechanical Durability
20000000 cycles
Maximum Actuation Speed
0.5 m/s
Minimum Force For Tripping
15 N
Contact Code Designation
A300, AC-15 (Ue = 240 V), Ie = 3 A EN/IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A
Width
64 mm
Depth
30 mm
[Ithe] Conventional Enclosed Thermal Current
10 A AC
Repeat Accuracy
0.05 mm on the tripping points with 1 million operating cycles
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110614EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || UL || CCC
Ik Degree Of Protection
IK05 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Standards
UL 508 || IEC 60947-5-1 || CSA C22.2 No 14 || IEC 60204-1 || EN 60204-1 || EN 60947-5-1
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)EN/IEC 60068-2-6
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I IEC 61140 || class I NF C 20-030
Protective Treatment
TC