282-360
- Nuevo20 piezas
- Desconocido1 pieza
Filtros
SUPPLEMENTARY PROTECTOR,1P,1.6A,CURVE D Supplementary Protector, UL1077 Rated, IEC Mini Circuit Breaker, 1 Pole, 1.6 Amps, 277 VAC, Trip Characteristic Curve D, 18mm Width, 70mm Depth, UL File E116386 in Vol. 1 Sec. 2
SUPPLEMENTARY PROTECTOR,1P,1.6A,CURVE D Supplementary Protector, UL1077 Rated, IEC Mini Circuit Breaker, 1 Pole, 1.6 Amps, 277 VAC, Trip Characteristic Curve D, 18mm Width, 70mm Depth, UL File E116386 in Vol. 1 Sec. 2
SENTRON, Molded case switch3LD5 UL, Emergencyswitching-off, 3-pole ,certified according to UL489UL60947-4-1 and IEC60947-3, UL:60A, SCCR 50kA at 480VAC,Operating power at 480VAC
SENTRON, Molded case switch3LD5 UL, Emergencyswitching-off, 3-pole ,certified according to UL489UL60947-4-1 and IEC60947-3, UL:60A, SCCR 50kA at 480VAC,Operating power at 480VAC
REDUCTING CLOMBS FROM 16QMM TO 2,5QMM OR 4QMM FROM SCREW TO SCREW
REDUCTING CLOMBS FROM 16QMM TO 2,5QMM OR 4QMM FROM SCREW TO SCREW
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA11 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 125A 3-POLE Icu: (10KAIC AT 690V) (55KAIC AT 415V). TM210 TRIP UNIT WITH FIXED Ir FIXED Ii. SPECIAL FEATURES: CONNECTION WITH LUG TERMINAL / NUT KEEPER. DIMENSIONS (W x H x D) IN: 3 x 5.1 x 3.5.
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA11 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 125A 3-POLE Icu: (10KAIC AT 690V) (55KAIC AT 415V). TM210 TRIP UNIT WITH FIXED Ir FIXED Ii. SPECIAL FEATURES: CONNECTION WITH LUG TERMINAL / NUT KEEPER. DIMENSIONS (W x H x D) IN: 3 x 5.1 x 3.5.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA51 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 25A 1-POLE (14KAIC AT 347V) (35KAIC AT 277V). TM210 TRIP UNIT WITH FIXED Ir FIXED Ii. SPECIAL FEATURES: WITHOUT LUGS. DIMENSIONS (W x H x D) IN: 1 x 5.5 x 3.7.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA51 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 25A 1-POLE (14KAIC AT 347V) (35KAIC AT 277V). TM210 TRIP UNIT WITH FIXED Ir FIXED Ii. SPECIAL FEATURES: WITHOUT LUGS. DIMENSIONS (W x H x D) IN: 1 x 5.5 x 3.7.
PILZ-DRUCK-ZUG-SCH./ROT UNBEL./1S+1OE Supplementary Protector, UL1077 Rated, IEC Mini Circuit Breaker, 1 Pole, 10 Amps, 277 VAC, Trip Characteristic Curve B, 18mm Width,70mm Depth, UL File E116386 in Vol. 1 Sec. 2
PILZ-DRUCK-ZUG-SCH./ROT UNBEL./1S+1OE Supplementary Protector, UL1077 Rated, IEC Mini Circuit Breaker, 1 Pole, 10 Amps, 277 VAC, Trip Characteristic Curve B, 18mm Width,70mm Depth, UL File E116386 in Vol. 1 Sec. 2
Inserts, Screw termination, Female, Polycarbonate (PC), RAL 7032 (pebble grey), Rated current: 16 A, Size: 6 B, Contacts: 6, Conductor cross-section: 0.75 ... 2.5 mm², Copper alloy, Silver plated
Inserts, Screw termination, Female, Polycarbonate (PC), RAL 7032 (pebble grey), Rated current: 16 A, Size: 6 B, Contacts: 6, Conductor cross-section: 0.75 ... 2.5 mm², Copper alloy, Silver plated
LC1K1210P7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 12A AC-3 5.5kW@400V, it includes a 230V 50/60Hz AC coil and 1NO auxiliary contact. LC1K1210P7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 5.5kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 230V 50/60Hz AC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NO built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).
LC1K1210P7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 12A AC-3 5.5kW@400V, it includes a 230V 50/60Hz AC coil and 1NO auxiliary contact. LC1K1210P7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 5.5kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 230V 50/60Hz AC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NO built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA11 FRAME WITH STANDARD (CLASS S) BREAKING CAPACITY. 50A 3-POLE Icu: (7KAIC AT 690V) (36KAIC AT 415V). TM210 TRIP UNIT WITH FIXED Ir FIXED Ii. SPECIAL FEATURES: CONNECTION WITH BOX TERMINAL / STEEL WRAP AROUND LUG. DIMENSIONS (W x H x D) IN: 3 x 5.1 x 3.5.
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA11 FRAME WITH STANDARD (CLASS S) BREAKING CAPACITY. 50A 3-POLE Icu: (7KAIC AT 690V) (36KAIC AT 415V). TM210 TRIP UNIT WITH FIXED Ir FIXED Ii. SPECIAL FEATURES: CONNECTION WITH BOX TERMINAL / STEEL WRAP AROUND LUG. DIMENSIONS (W x H x D) IN: 3 x 5.1 x 3.5.
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA20 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 25A 3-POLE Icu: (2KAIC AT 690V) (110KAIC AT 415V). ETU320 TRIP UNIT LI. SPECIAL FEATURES: CONNECTION WITH BOX TERMINAL / STEEL WRAP AROUND LUG. DIMENSIONS (W x H x D) IN: 4.1 x 7.1 x 4.2.
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA20 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 25A 3-POLE Icu: (2KAIC AT 690V) (110KAIC AT 415V). ETU320 TRIP UNIT LI. SPECIAL FEATURES: CONNECTION WITH BOX TERMINAL / STEEL WRAP AROUND LUG. DIMENSIONS (W x H x D) IN: 4.1 x 7.1 x 4.2.
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA20 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 40A 4-POLE Icu: (2KAIC AT 690V) (55KAIC AT 415V). ETU850 TRIP UNIT LCD LSI WITH METERING. SPECIAL FEATURES: CONNECTION WITH LUG TERMINAL / NUT KEEPER. DIMENSIONS (W x H x D) IN: 5.5 x 7.1 x 4.2.
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA20 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 40A 4-POLE Icu: (2KAIC AT 690V) (55KAIC AT 415V). ETU850 TRIP UNIT LCD LSI WITH METERING. SPECIAL FEATURES: CONNECTION WITH LUG TERMINAL / NUT KEEPER. DIMENSIONS (W x H x D) IN: 5.5 x 7.1 x 4.2.
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA20 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 63A 3-POLE Icu: (2KAIC AT 690V) (110KAIC AT 415V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES: CONNECTION WITH LUG TERMINAL / NUT KEEPER. DIMENSIONS (W x H x D) IN: 4.1 x 7.1 x 4.2.
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA20 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 63A 3-POLE Icu: (2KAIC AT 690V) (110KAIC AT 415V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES: CONNECTION WITH LUG TERMINAL / NUT KEEPER. DIMENSIONS (W x H x D) IN: 4.1 x 7.1 x 4.2.
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA24 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 400A 4-POLE Icu: (6KAIC AT 690V) (55KAIC AT 415V). ETU850 TRIP UNIT LCD LSI WITH METERING. SPECIAL FEATURES: CONNECTION WITH LUG TERMINAL / NUT KEEPER. DIMENSIONS (W x H x D) IN: 7.2 x 9.8 x 5.4.
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA24 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 400A 4-POLE Icu: (6KAIC AT 690V) (55KAIC AT 415V). ETU850 TRIP UNIT LCD LSI WITH METERING. SPECIAL FEATURES: CONNECTION WITH LUG TERMINAL / NUT KEEPER. DIMENSIONS (W x H x D) IN: 7.2 x 9.8 x 5.4.
SIEMENS LOW VOLTAGE 3VA IEC MOTOR CIRCUIT PROTECTOR WITH ELECTRONIC TRIP UNIT. 3VA24 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 400A 3-POLE Icu: (6KAIC AT 690V) (110KAIC AT 415V). ETU310M TRIP UNIT WITH ADJUSTABLE Ii. SPECIAL FEATURES: CONNECTION WITH LUG TERMINAL / NUT KEEPER. DIMENSIONS (W x H x D) IN: 5.4 x 9.8 x 5.4.
SIEMENS LOW VOLTAGE 3VA IEC MOTOR CIRCUIT PROTECTOR WITH ELECTRONIC TRIP UNIT. 3VA24 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 400A 3-POLE Icu: (6KAIC AT 690V) (110KAIC AT 415V). ETU310M TRIP UNIT WITH ADJUSTABLE Ii. SPECIAL FEATURES: CONNECTION WITH LUG TERMINAL / NUT KEEPER. DIMENSIONS (W x H x D) IN: 5.4 x 9.8 x 5.4.