Schmersal
101181066
CSS 14-34-S-SD-M-ST
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Condiciones del producto:
Additional Information
- Part Number
- 101181066
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : End switch
- Class Code : EC000030
- Version : 7
Electrical data - Serial diagnostic SD
- Designation, Serial diagnostic SD
- OUT
- Operation current
- 150 mA
- Design of control elements
- short-circuit proof, p-type
- Wiring capacitance
- 50 nF
Electrical data
- No-load supply current I
- 100 mA
- Operating current
- 600 mA
- Required rated short-circuit current
- 100 A
- Note (Electrical data, Fuse rating)
- (Circuit breaker)
- Switching frequency, approx.
- 3 Hz
Note
- Note (General)
- Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circuit recognition by the evaluation is not necessary.
Mechanical data - Dimensions
- Length of sensor
- 35 mm
- Width of sensor
- 27 mm
- Height of sensor
- 108.2 mm
Pin assignment
- PIN 1
- 1A1 Ue: (1)
- PIN 2
- X1 Safety input 1
- PIN 3
- A2 GND
- PIN 4
- Y1 Safety output 1
- PIN 5
- SD serial diagnostic output
- PIN 6
- X2 Safety input 2
- PIN 7
- Y2 Safety output 2
- PIN 8
- IN serial diagnostic input
Ambient conditions - Insulation values
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 3
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately.
General data - Features
- Serial diagnostics
- Yes
- Diagnostic output
- Yes
- Short circuit detection
- Yes
- Cross-circuit detection
- Yes
- Safety functions
- Yes
- Cascadable
- Yes
- Integral system diagnostics, status
- Yes
- Number of LEDs
- 3
- Number of semi-conductor outputs with signaling function
- 1
- Number of fail-safe digital outputs
- 2
- Number of series-wiring of sensors
- 31
General data
- Standards
- EN IEC 60947-5-3
- Working principle
- inductive
- Housing construction form
- Block
- Installation conditions (mechanical)
- not flush
- Sensor topology
- Sensor for series wiring
- Enclosure material
- Glass-fibre, reinforced thermoplastic
- Active area
- Glass-fibre, reinforced thermoplastic
- Gross weight
- 140 g
- Reaction time, maximum
- 30 ms
- Duration of risk, maximum
- 60 ms
Safety classification
- Standards
- EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 3.60 x 10⁻⁹ /h
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Electrical data - Safety digital outputs
- Rated operating current (safety outputs)
- 250 mA
- Output current, (fail-safe output), maximum
- 0.25 A
- Design of control elements
- p-type
- Voltage drop U
- 0.5 V
- Leakage current I
- 0.5 mA
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.25 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.25 A
Ambient conditions
- Degree of protection
- IP65 | IP67
- Ambient temperature
- -25 ... +70 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +85 °C
- Resistance to vibrations
- 10 … 55 Hz, amplitude 1 mm
- Restistance to shock
- 30 g / 11 ms
- Protection class
- II
Mechanical data - Connection technique
- Termination
- Connector plug M12, 8-pole
- Note (length of the sensor chain)
- Cable length and cross-section change the voltage drop dependiing on the output current
- Note (series-wiring)
- Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Electrical data - Diagnostic outputs
- Design of control elements
- p-type
- Voltage drop U
- 5 V
Mechanical data - Switching distances according EN IEC 60947-5-3
- Nominal switching distance S
- 10 mm | 14 mm
- Assured switching distance "ON" S
- 12 mm | 8 mm
- Assured switching distance "OFF" S
- 13 mm | 17 mm
Mechanical data
- Actuating panels
- lateral
- Active area
- lateral
- Switching distance actuator
- Actuator CST 180-1 / CST 180-2: 10 mm | Actuator CST 180-1 / CST 180-2: 13 mm | Actuator CST 180-1 / CST 180-2: 8 mm | Actuator CST 34-S-1: 12 mm | Actuator CST 34-S-1: 14 mm | Actuator CST 34-S-1: 17 mm | Actuator CST 34-S-2: 12 mm | Actuator CST 34-S-2: 14 mm | Actuator CST 34-S-2: 17 mm | Actuator CST 34-S-3: 12 mm | Actuator CST 34-S-3: 14 mm | Actuator CST 34-S-3: 17 mm
- Hysteresis (Switching distance), maximum
- 1.5 mm
- Repeat accuracy R
- 0.5 mm
- Note (Repeat accuracy R)
- Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 36 mm (e.g. mounting tolerance or due to guard door sagging). Increased misalignment, max. 53 mm, possible when the CST 34-S-2 actuator is used. The axial misalignment (y) is max. ± 10 mm (see figure: Operating principle)
Accessory
- Recommendation (actuator)
- CST 34-S-2 | CST 34-S-3 | CST 180-1 | CST 180-2 | CST 34-S-1
- Recommended safety switchgear
- PROTECT PSC1 | SRB-E-301ST | SRB-E-201LC
Approvals - Standards
- Certificates
- TÜV | cULus | UKCA
Electrical data - Electromagnetic compatibility (EMC)
- Interfering radiation
- IEC 61000-6-4
- EMC rating
- IEC 61000-6-2
Modelos CAD
Rastrear piezas
DescargarOtras categorías
NanómetrosManómetrosFlujómetrosSensoresSensores de aceleraciónSensores de fibra ópticaDetectoresSensores ultrasónicosSensores de temperatura y humedadSensores de vibraciónSensores de nivelSensores de presiónSensores de proximidadSensores InductivosSensores de movimientoGrupo de Sensores MagnéticosSensores ópticosSensores CapacitivosSensores FotoeléctricosSensores de posiciónCodificadoresOtros Sensores y Accesorios