Schmersal

103026879

AZM201D-ST2-T-1P2P2P
103026879
103026879
103026879
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Solicite un presupuesto y le enviaremos información sobre disponibilidad y precio.

Electrical data - Safety digital inputs

Switching thresholds
−3 V … 5 V (Low) | 15 V … 30 V (High)
Test pulse duration, maximum
1 ms
Test pulse interval, minimum
100 ms
Classification ZVEI CB24I, Sink
C1
Classification ZVEI CB24I, Source
C1 | C2 | C3

Electrical data

Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
No-load supply current I
50 mA
Current consumption with magnet ON, peak
700 mA / 100 ms
Rated operating voltage
24 VDC
Operating current
1,200 mA
Required rated short-circuit current
100 A
Time to readiness, maximum
4,000 ms
Switching frequency, maximum
1 Hz

Note

Note (General)
As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.
Note (Actuator monitored)
Safety outputs Y1, Y2
Note (Solenoid interlock monitored)
Safety outputs Y3, Y4

Mechanical data - Dimensions

Length of sensor
50 mm
Width of sensor
40 mm
Height of sensor
220 mm

Pin assignment

PIN 1
A1 Supply voltage UB
PIN 2
OUT diagnostic output
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
Y3 safety output 3
PIN 6
Y4 safety output Y4
PIN 7
Y2 Safety output 2
PIN 8
IN Solenoid control

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately. | Triangular key for AZM 201

Electrical data - Magnet control

Designation, Magnet control
IN
Switching thresholds
-3 V … 5 V (Low) | 15 V … 30 V (High)
Magnet switch-on time
100 %
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
40 ms
Classification ZVEI CB24I, Sink
C0
Classification ZVEI CB24I, Source
C1 | C2 | C3

General data - Features

Power to unlock
Yes
Actuator monitored
Yes
Solenoid interlock monitored
Yes
Manual release
Yes
Short circuit detection
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of safety contacts
4

General data

Standards
EN IEC 62061 | EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-3 | EN IEC 61508
Coding
Universal coding
Coding level according to EN ISO 14119
Low
Working principle
RFID
Frequency band RFID
125 kHz
Transmitter output RFID, maximum
-6 dB/m
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
588 g
Duration of risk, maximum
200 ms
Reaction time, switching off safety outputs via actuator, maximum
100 ms
Reaction time, switching off safety outputs via safety inputs, maximum
0.5 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 62061 | EN IEC 61508
Performance Level, up to
d
Category
3
Safety Integrity Level (SIL), suitable for applications in
2
Mission time
20 Year(s)

Electrical data - Safety digital outputs

Designation, Safety outputs
Y1 and Y2
Rated operating current (safety outputs)
250 mA
Voltage drop U
4 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A
Note, Utilisation category DC-13
Gilt für die Ausgänge Y1 und Y2
Test pulse interval, typical
1000 ms
Test pulse duration, maximum
0.5 ms
Classification ZVEI CB24I, Source
C2
Classification ZVEI CB24I, Sink
C1 | C2

Safety classification - Interlocking function

Performance Level, up to
e
Category
4
PFH value
5.70 x 10⁻¹⁰ /h
PFD value
5.00 x 10⁻⁵
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Ambient conditions

Degree of protection
IP67 | IP66
Ambient temperature
-25 ... +60 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Relative humidity, minimum
30 %
Relative humidity, maximum
95 %
Note (Relative humidity)
non-condensing
Resistance to vibrations
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock
30 g / 11 ms
Protection class
III

Mechanical data - Connection technique

Termination
Connector M12, 8-pole
Length of sensor chain, maximum
200 m
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD

Electrical data - Diagnostic outputs

Operating current
100 mA
Voltage drop U
4 V
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A

Safety classification - Guard locking function

Mission time
20 Year(s)

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Holding force F
2,000 N
Note (clamping force F
1,000 N when used with the AZ/AZM201-B30 actuator, for indoor use.
Holding force F
2,600 N
Note (clamping force F
1,300 N when used with the AZ/AZM201-B30 actuator, for indoor use.
Latching force
30 N
Actuating speed, maximum
0.2 m/s
Type of the fixing screws
2x M6
Tightening torque of the fastening screws for the housing cover, minimum
0.7 Nm
Tightening torque of the fastening screws for the housing cover, maximum
1 Nm
Note
Torx T10

Accessory

Recommendation (actuator)
AZ/AZM201-B1 | AZ/AZM201-B30

Approvals - Standards

Certificates
TÜV | cULus | FCC | IC

Status indication

Note (LED switching conditions display)
Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green

Modelos CAD

Rastrear piezas
Rastrear piezas
Descargar