Schmersal
101209119
AZM 161 BZ ST1-AS R
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
Enviar solicitud de precio
Additional Information
- Part Number
- 101209119
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Position switch with guard locking
- Class Code : EC002593
- Version : 7
Electrical data
- Switching frequency
- 1,000 /h
Electrical data - AS-Interface specification
- AS-i Specification
- Safety-Slave
- AS-i Version
- V 2.1
- AS-i Profile
- S-7.B.F.E
- AS-i, IO-Code
- 0x7
- AS-i, ID-Code
- 0xB
- AS-i, ID-Code1
- 0xF
- AS-i, ID-Code2
- 0xE
- AS-i Input, Channel 1
- Data bits DI 0 / DI 1 = dynamic code transmission
- AS-i Input, Channel 2
- Data bits DI 2 / DI 3 = dynamic code transmission
- AS-i Outputs, DO 0
- Solenoid control
- AS-i Outputs, DO 1
- No Function
- AS-i Outputs, DO 2
- No Function
- AS-i Outputs, DO 3
- No Function
- AS-i Parameter bits, P0
- Actuator detected
- AS-i Parameter bits, P1
- Solenoid interlock locked
- AS-i Parameter bits, P2
- Magnet voltage in tolerance range
- AS-i Parameter bits, P3
- Error message - locking/unlocking of the solenoid interlock blocked
- Note (AS-i Parameter bits)
- Set the parameter outputs to "1111" (0xF) | FID: periphery error
- AS-i Input module address
- 0
- Note (AS-i Input module address)
- Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Note
- Note (General)
- Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened.
- Note (Manual release)
- For maintenance, installation, etc. | For manual release using M5 triangular key, available as accessory
Mechanical data - Dimensions
- Length of sensor
- 30 mm
- Width of sensor
- 130 mm
- Height of sensor
- 90 mm
Pin assignment
- PIN 1
- AS-i +
- PIN 2
- Aux - (P)
- PIN 3
- AS-Interface -
- PIN 4
- Aux + (P)
Ambient conditions - Insulation values
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 3
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately.
General data - Features
- Power to unlock
- Yes
- Actuator and interlock combined monitored
- Yes
- Manual release
- Yes
- Integral system diagnostics, status
- Yes
- Number of actuating directions
- 3
General data
- Standards
- EN IEC 62026-2 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 61508
- Coding level according to EN ISO 14119
- Low
- Working principle
- electromechanical
- Enclosure material
- Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Gross weight
- 465 g
- Reaction time, maximum
- 100 ms
Safety classification
- Standards
- EN ISO 13849-1 | EN IEC 61508
- Performance Level, up to
- c
- Category
- 1
- PFH value
- 1.14 x 10⁻⁶ /h
- Note (PFH-value)
- up to max. 100,000 switching cycles/year
- Safety Integrity Level (SIL), suitable for applications in
- 1
- Mission time
- 20 Year(s)
- Please note:
- Einsetzbar wenn ein Fehlerausschluss für eine gefahrbringende Beschädigung der 1-kanaligen Mechanik zulässig ist und ein ausreichender Manipulationsschutz gewährleistet ist.
- Performance Level, up to
- d
- Category
- 3
- PFH value
- 1.01 x 10⁻⁷ /h
- Safety Integrity Level (SIL), suitable for applications in
- 2
Electrical data - AS Interface
- Rated operating voltage
- 26.5 ... 31.6 VDC (Protection against polarity reversal)
- AS-i Current consumption, maximum
- 250 mA
Other data
- Note (applications)
- sliding safety guard | removable guard | hinged safety guard
Ambient conditions
- Degree of protection
- IP67
- Ambient temperature
- -25 ... +60 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +85 °C
- Relative humidity, minimum
- 30 %
- Relative humidity, maximum
- 95 %
- Note (Relative humidity)
- non-condensing | non-icing
- Resistance to vibrations
- 10 Hz ... 150 Hz, amplitude 0.35 mm
- Restistance to shock
- 30 g / 11 ms
- Protection class
- II
- Permissible installation altitude above sea level, maximum
- 2,000 m
Mechanical data - Connection technique
- Termination
- Connector plug M12, 4-pole, (A-coding)
- Connector position
- Bottom
Mechanical data
- Mechanical life, minimum
- 1,000,000 Operations
- Actuating play in direction of actuation
- 5.5 mm
- Holding force F
- 2,000 N
- Holding force F
- 2,600 N
- Latching force
- 30 N
- Actuating speed, maximum
- 2 m/s
- Mounting
- Screws
- Type of the fixing screws
- 3x M6
Approvals - Standards
- Certificates
- TÜV | cULus | ASi-SaW
Status indication
- Note (LED switching conditions display)
- (1) LED yellow: Channel 2 / AS-i SaW Bit 2.3 | (2) LED green/red (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected | (3) LED yellow: Channel 1 / AS-i SaW Bit 0.1
Otras categorías
NanómetrosManómetrosFlujómetrosSensoresSensores de aceleraciónSensores de fibra ópticaDetectoresSensores ultrasónicosSensores de temperatura y humedadSensores de vibraciónSensores de nivelSensores de presiónSensores de proximidadSensores InductivosSensores de movimientoGrupo de Sensores MagnéticosSensores ópticosSensores CapacitivosSensores FotoeléctricosSensores de posiciónCodificadoresOtros Sensores y Accesorios