Honeywell Ricambi per Automazione Industriale

Honeywell logo

509 risultati

VR3G7LPF4/M Honeywell, Valvole di processo e controllo portata
Honeywell

VR3G7LPF4/M

3-Way Resilient Seated Butterfly Valve 2.5" 2-10VDC

Su richiesta

The 3-Way Resilient Seated Butterfly Valve 2.5" 2-10VDC is designed for precise control in HVAC applications involving chilled or hot water systems. With a valve body constructed from epoxy powder coated ductile iron (ASTM A536) and a valve disc made of 304 stainless steel, this valve ensures durability and reliability in demanding environments.Featuring a maximum operating pressure of 232 psi (1600 kPa) and a maximum media temperature of 250 °F (121 °C), this valve is suitable for a variety of applications. The valve's flanged connection type is compatible with ANSI Class 125/150 and is secured using four bolts of 0.625 in size, arranged with a pitch of 11. Additionally, the valve stem is crafted from 416 stainless steel, while the seat is made from EPDM material, contributing to its effective sealing capabilities.This valve operates with a fail-in-place actuator, designed for NEMA 4X IP66/67 environments, ensuring reliability even in the event of a power failure. The actuator control signal is modulating, allowing for fine adjustments and improved control of fluid flow. Its flow characteristic is modified linear, with a flow coefficient of 75 CV (65 Kvs), allowing for efficient fluid management.For optimal functionality, it is essential that this valve is not used with steam or fuels, and it accommodates media with up to 60% glycol. The valve's start position is normally closed at Port A, and it has a maximum differential pressure rating of 200 psi (1380 kPa).For further specifications, the valve is regulatory approved by CE and cULus.

Disponibile in:
US
Richiedi un preventivo
E20-2083200J-G-KIT Honeywell, Alimentazione
Honeywell

E20-2083200J-G-KIT

CLASS 2000 SUBMETER, 3 Phase, 3200 A, 120/208-240 V AC

Su richiesta

The Class 2000 (H20) meter is designed for three-phase power monitoring, providing accurate kW and kWh data essential for commercial and industrial applications. This revenue-grade device includes one set of split-core current sensors, allowing for precise measurements. Compliance with ANSI C12.20 and UL/CUL standards ensures reliability in various operating environments.With an operational temperature range from -4 °F to 122 °F and a maximum humidity level of 95% non-condensing, this submeter is suitable for diverse conditions. The meter supports both 3 and 4 wire input voltage configurations and operates at frequencies of 50 Hz and 60 Hz. It features a 2-line LCD display for ease of use and has a current sensor output of 2 V.This model, classified under Class 2000, achieves an accuracy of ±1% across the entire rated load range, making it a dependable choice for energy monitoring. The enclosure is constructed from JIC Steel, enhancing durability in demanding environments. The meter is compatible with WEBs-AX Energy Analytics Tenant Billing and E-mon Energy Software, facilitating seamless integration into existing energy management systems.

Disponibile in:
US
Richiedi un preventivo
E50-208400-J04-SPKIT Honeywell, Sensori di prossimità e induttivi
Honeywell

E50-208400-J04-SPKIT

Class 5000 Submeter, 1 or 2 Phase, 400 A, 120/208-240 V AC

Su richiesta

The Class 5000 (H50) Smart Meters provide enhanced dual protocol communication capabilities, allowing for simultaneous connectivity with two energy monitoring systems. This includes integration with Building Automation Systems (BAS) for energy monitoring and billing purposes, as well as Measurement & Verification (M&V) reporting tools. Featuring a large 4-line LCD display with backlighting, these meters facilitate clear visibility of readings. Communication options include RS485 and Ethernet, ensuring versatility in data transmission. The device is designed for 1 or 2 phase operation, with a current rating of 400 A and an input voltage configuration of 120/208-240 V AC. Notably, the meters comply with ANSI C12.20 and UL/CUL regulations, ensuring reliable performance. The enclosure is constructed from JIC Steel, providing durability in various environments. With an accuracy of ±1% across the rated load range, the Class 5000 is suitable for rigorous commercial and industrial applications, offering 38 data points for comprehensive monitoring of electrical usage.

Disponibile in:
US
Richiedi un preventivo
E50-4001600R08-SPKIT-NS Honeywell, Alimentazione
Honeywell

E50-4001600R08-SPKIT-NS

CLASS 5000 SUBMETER - NO SENSORS, 1 or 2 Phase, 1600 A, 230/400 V AC

Su richiesta

The Class 5000 (H50) Smart Meter is designed for advanced energy monitoring in commercial and industrial environments. It features dual protocol communications, enabling simultaneous interaction with up to two energy monitoring systems, such as building automation systems (BAS) and measurement and verification (M&V) reporting tools. This meter is equipped with a 4-line LCD display with backlight for enhanced visibility. It supports 1 or 2 phase configurations and can measure current up to 1600 A. The input voltage configuration allows for both 3 and 4 wire setups, operating within a frequency range of 50 Hz to 60 Hz. With an accuracy rating of ±1% from 1% to 100% of the rated load, it ensures reliable performance. Regulatory approvals include CE and UL/CUL certifications, and the device is housed in a NEMA 4X enclosure for protection against dust and moisture. The meter operates effectively in a temperature range from -20 °C to 50 °C, with a maximum operating humidity of 95% non-condensing. Communication protocols supported include LonWorks TP/FT-10 and Modbus TCP/IP, making it suitable for various applications.

Disponibile in:
US
Richiedi un preventivo
E20-208400-R-G-KIT-NS Honeywell, Alimentazione
Honeywell

E20-208400-R-G-KIT-NS

CLASS 2000 SUBMETER - NO SENSORS, 3 Phase, 400 A, 120/208-240 V AC

Su richiesta

The Class 2000 SUBMETER is engineered to provide precise kW and kWh measurements for three-phase electrical systems. This device operates within a voltage range of 120/208-240 V AC and supports current loads up to 400 A. Notably, it does not include current sensors, making it suitable for applications requiring flexible sensor integration.Compliant with ANSI C12.20 and UL/CUL standards, this meter features a NEMA 4X enclosure, ensuring reliable performance in various environmental conditions. It operates effectively in ambient temperatures ranging from -4 °F to 122 °F and can tolerate humidity levels up to 95% non-condensing.The meter includes a 2-line LCD display for easy data visualization and utilizes pulse output communication protocols. With an accuracy rating of ±1% across the full load spectrum, this device is ideal for monitoring electrical consumption in commercial and industrial settings. The Class 2000 designation signifies its revenue-grade quality, making it a trusted choice for energy analytics and tenant billing applications.

Disponibile in:
US
Richiedi un preventivo
TP9610A1006/U Honeywell, Controllo e HMI
Honeywell

TP9610A1006/U

Pneumatic Thermostats, THERMOSTAT

Su richiesta

Pneumatic thermostats and humidistats serve the function of regulating pneumatic valves and dampers within HVAC installations. These devices come in various configurations including wall mount, duct mount, and remote bulb options, catering to different installation needs.Specific models are tailored for diverse operational requirements such as single setpoint, day/night, and summer/winter functionalities. The throttling range spans from 10 °F to 2 °F, with a bimetal sensor element ensuring precise temperature control. The unit dimensions are as follows: an overall width of 2 in (51 mm), an overall height of 83 mm, and an overall depth of 1.625 in (41 mm).In terms of temperature settings, the nighttime minimum setpoint is 50 °F (10 °C) and the maximum setpoint reaches 75 °F (27 °C). The device operates effectively at a maximum operating pressure of 25 psi (170 kPa). Notably, the thermostat features visible settings for cover, setpoint, and thermometer, enhancing user interaction.The daytime settings allow for a minimum of 59 °F (15 °C) and a maximum of 90 °F (30 °C), while the cooling settings mirror these ranges. Airflow usage is rated at 0.011 cfm (5.2 ml/s), with air connections utilizing barb fittings with an outer diameter of 0.15625 in (4 mm). This product is categorized as a direct acting wall thermostat, suitable for day/night operation.

Richiedi un preventivo
VH4K7UPBH/M Honeywell, Valvole di processo e controllo portata
Honeywell

VH4K7UPBH/M

Butterfly Valve, 3-Way, CL150, 5 in, 2-10 VDC

Su richiesta

The 3-way butterfly valve is designed for versatile applications, including chilled, hot, and cooling tower water systems, as well as two-position steam applications capable of handling pressures up to 50 psi. With a pipe connection size of 5 inches and built according to ASME/ANSI Class 150 standards, this valve ensures reliable performance across various environments.Constructed from carbon steel with a valve body pattern that facilitates mixing, it features a valve disc made from 316 stainless steel and a valve seat of RTFE. The valve operates with a flow characteristic that is modified linear and unidirectional, providing a flow coefficient of 393 CV (340 Kvs). It is equipped with a fail-in-place actuator that meets NEMA 4X IP66/67 standards, ensuring durability and performance stability.Operational temperatures range from a minimum of -22 °F (-30 °C) to a maximum of 400 °F (204 °C), while the valve maintains a maximum body pressure rating of ASME/ANSI Class 150 and a maximum differential pressure of 150 psi (1034 kPa). The valve is normally closed and includes a manual operation type with a 7 mm hex crank for additional control.It is important to note that this valve is not suitable for use with fuels or modulating steam and is designed to operate efficiently in systems with controlled media such as on/off steam control or chilled/hot water with up to 60% glycol.

Disponibile in:
US
Richiedi un preventivo
E50-208800-R06NSPKIT Honeywell, Accessori generali
Honeywell

E50-208800-R06NSPKIT

CLASS 5000 SUBMETER, 1 or 2 Phase, 800 A, 120/208-240 V AC

Su richiesta

The Class 5000 Smart Meters are designed for efficient energy monitoring and feature advanced dual protocol communications. They allow for simultaneous connectivity to two energy monitoring systems, which can include building automation systems and billing programs or measurement and verification reporting tools. A notable feature is the 4-line LCD display, which is backlit for improved visibility in various lighting conditions.With an operational temperature range from -4 °F to 122 °F and a maximum humidity tolerance of 95% non-condensing, this submeter is suited for diverse environments. The device supports both 3 and 4 wire input voltage configurations, making it versatile for different applications. It is built to withstand tough conditions with a NEMA 4X enclosure, ensuring reliability in commercial and industrial uses.The Class 5000 model incorporates two split-core current sensors, providing accurate readings with a precision of ±1% across the rated load range. It communicates via Modbus RTU and Modbus TCP/IP protocols. This capability is essential for modern energy management systems, allowing for detailed monitoring of electrical usage, which is crucial for optimizing energy consumption and enhancing operational efficiency.

Disponibile in:
US
Richiedi un preventivo
E34-600800-J07-SPKIT Honeywell, Sensori di prossimità e induttivi
Honeywell

E34-600800-J07-SPKIT

3400 SUBMETER, 1 or 2 Phase, 800 A, 347/600 V AC

Su richiesta

The Class 3400 Smart Meters, identified by the designation code H34, are equipped with advanced dual protocol communications, facilitating simultaneous interaction with two energy monitoring systems. These systems may include Building Automation Systems (BAS) for energy monitoring, billing programs, and Measurement & Verification (M&V) reporting tools. An optional feature package provides built-in load control functions and two pulse outputs for kWh and kVARh measurements.Featuring a large 4-line LCD display with backlight, the meter offers RS485 and Ethernet communication options. The device is designed for versatility, accommodating either 1 or 2-phase configurations with a current capacity of 800 A and input voltage configuration of 347/600 V AC. Its robust design meets regulatory approvals including ANSI C12.20 and UL/CUL standards.With an accuracy rating of ±1% across a load range of 1% to 100%, the Class 3400 provides reliable performance in commercial and industrial applications. It also features a split-core current sensor output of 2 V and is rated for operation in ambient temperatures ranging from -4 °F (-20 °C) to 122 °F (50 °C), with a maximum humidity tolerance of 95% non-condensing.

Disponibile in:
US
Richiedi un preventivo
E20-480100-JKIT-NS Honeywell, Alimentazione
Honeywell

E20-480100-JKIT-NS

CLASS 2000 SUBMETER - NO SENSORS, 3 Phase, 100 A, 277/480 V AC

Su richiesta

The Class 2000 (H20) meters deliver precise kW and kWh data for three-phase electrical systems, making them suitable for commercial and industrial applications. This variant operates without included sensors, supporting a maximum current of 100 A and voltages of 277/480 V AC. It features a 2-line LCD display for easy reading of energy consumption metrics. With a regulatory approval of ANSI C12.20 and UL/CUL, this submeter ensures compliance with industry standards. It operates effectively within a temperature range of -4 °F to 122 °F (-20 °C to 50 °C) and can withstand maximum humidity levels of 95% non-condensing. The device is designed for 3 or 4 wire input voltage configurations and offers a communication protocol via pulse output. Weighing 5.1 lbs and measuring 6 in (152 mm) in width, 7.5 in (171 mm) in height, and 3 in (76 mm) in depth, the submeter's enclosure is constructed from JIC steel for durability. This meter guarantees accuracy of ±1% across a load range of 1% to 100%, ensuring reliable monitoring of electrical usage.

Disponibile in:
US
Richiedi un preventivo
E34-4803200J08-X-KIT Honeywell, Alimentazione
Honeywell

E34-4803200J08-X-KIT

CLASS 3400 SUBMETER, 3 Phase, 3200 A, 277/480 V AC

Su richiesta

The Class 3400 (H34) Smart Meters offer advanced dual protocol communications, allowing for simultaneous connectivity with up to two energy monitoring systems. These systems may include Building Automation Systems (BAS) for energy monitoring, billing programs, and Measurement & Verification (M&V) reporting tools. An optional expanded feature package enhances functionality with built-in load control capabilities and two pulse outputs for kWh and kVARh.Equipped with an advanced four-line LCD display and supporting both RS485 and Ethernet communications, this submeter is engineered for rigorous commercial and industrial environments. It adheres to regulatory standards such as ANSI C12.20 and UL/CUL, ensuring reliable performance. The overall dimensions are 6.5 inches in width, 7.8 inches in height, and 3.4 inches in depth, with a total weight of 16.98 lbs.Operating conditions are well-suited for a wide range, with a minimum ambient temperature of -4 °F (-20 °C) and a maximum of 122 °F (50 °C), alongside a humidity tolerance of up to 95% non-condensing. The meter operates with a 3 or 4 wire input voltage configuration and supports frequency ranges of 50 Hz and 60 Hz. The Class 3400 features a current sensor output of 2 V and includes three split-core current sensors, achieving an accuracy of ±1% across its rated load range.

Disponibile in:
US
Richiedi un preventivo
E50-400400-J06-SPKIT-NS Honeywell, Alimentazione
Honeywell

E50-400400-J06-SPKIT-NS

CLASS 5000 SUBMETER - NO SENSORS, 1 or 2 Phase, 400 A, 230/400 V AC

Su richiesta

The Class 5000 (H50) Smart Meter integrates advanced dual protocol communications, facilitating simultaneous connectivity with two energy monitoring systems. This includes integration with Building Automation Systems for energy monitoring, billing applications, and Measurement & Verification (M&V) reporting tools. The meter features an advanced 4-line LCD display with backlight capabilities, providing clear visibility of critical data. With compliance to ANSI C12.20 and UL/CUL regulatory standards, the meter is designed for robust performance in commercial and industrial environments. It supports both 1 and 2 phase configurations, with a maximum current rating of 400 A and input voltage configurations of 230/400 V AC. The operating temperature range extends from -20 °C to 50 °C, and it can function effectively in environments with humidity levels up to 95% non-condensing. The design includes no current sensors, and it operates with a split-core current sensor type. Communication is facilitated through Modbus RTU and Modbus TCP/IP protocols. The enclosure is made of JIC steel, ensuring durability and protection in various settings. This Class 5000 submeter is engineered for high accuracy, maintaining an accuracy rating of ±1% across the full load range.

Disponibile in:
US
Richiedi un preventivo
HVFDSB3A0020G320/U Honeywell, Controllo e HMI
Honeywell

HVFDSB3A0020G320/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 2 HP, NEMA 3R Enclosure

Su richiesta

The VFD with Bypass and Disconnect, SmartVFD BYPASS, operates at an input voltage of 208 (3PH) V AC, providing a power output of 2 HP. This device is specifically designed for HVAC systems, enabling energy savings by modulating the speed of fans and pumps.Equipped with a NEMA 3R enclosure, this VFD supports a two contactor bypass configuration. The continuous output current is rated at 8 A, with overload capabilities of 1.1 x IL for 1 minute and 10 minutes. The device features an integrated control transformer and is compatible with building automation systems or can function independently through its internal PID capabilities.With dimensions of 24.5 in (622 mm) in width, 24 in (610 mm) in height, and a depth of 10.5 in (267 mm), the VFD weighs 22.3 lbs (49 kg). It operates efficiently within a temperature range of 14 °F (-10 °C) to 104 °F (40 °C) and can withstand storage temperatures from -40 °F (-40 °C) to 158 °F (70 °C). The maximum operating humidity is 95%.This drive is engineered to facilitate variable torque applications and includes features such as startup wizards and PC programming capabilities for streamlined commissioning, enhancing operational efficiency.

Richiedi un preventivo
E50-208100-R02KIT-NS Honeywell, Alimentazione
Honeywell

E50-208100-R02KIT-NS

CLASS 5000 SUBMETER - NO SENSORS, 3 Phase, 100 A, 120/208-240 V AC

Su richiesta

The Class 5000 (H50) Smart Meters are designed for advanced energy monitoring in commercial and industrial settings. These meters support dual protocol communications, allowing simultaneous interaction with two energy monitoring systems, including Building Automation Systems (BAS) and measurement and verification (M&V) reporting tools. The device is equipped with a large backlit 4-line LCD display, and it facilitates RS485 and Ethernet communications. With a current rating of 100 A and an input voltage setup of 120/208-240 V AC, this model is capable of operating under a wide temperature range, from -20 °C to 50 °C, and is protected against moisture with a NEMA 4X enclosure type. The Class 5000 meters maintain an accuracy of ±1% across the load range, making them reliable for precise electrical usage monitoring. Additionally, this variant does not include current sensors, ensuring a streamlined design for users who require basic monitoring capabilities.

Disponibile in:
US
Richiedi un preventivo
E34-480100-R08SCS Honeywell, Accessori generali
Honeywell

E34-480100-R08SCS

CLASS 3400 SUBMETER, 3 Phase, 100 A, 277/480 V AC

Su richiesta

The Class 3400 Smart Meters, designated as H34, support advanced dual protocol communications, facilitating concurrent interaction with up to two energy monitoring systems. This includes integration with Building Automation Systems (BAS), energy monitoring, billing programs, and Measurement & Verification (M&V) reporting tools.An optional feature package enhances functionality with built-in load control capabilities and two pulse outputs for kWh and kVARh. The device is equipped with a large four-line LCD display, ensuring clear visibility of data, and supports both RS485 and Ethernet communication interfaces.Regulatory approvals include ANSI C12.20 and UL/CUL certifications. The meter's dimensions are as follows: an overall width of 6.5 inches (166 mm), height of 7.8 inches (198 mm), and depth of 3.4 inches (86 mm). Weighing in at 7.33 pounds, it is designed to operate efficiently in environments with an ambient temperature range of -4 °F to 122 °F and a maximum humidity level of 95% non-condensing.As a fully electronic meter, the Class 3400 provides high accuracy of ±1% across the load range of 1% to 100% of rated capacity, featuring three solid-core current sensors for precise monitoring. The device is suitable for three-phase input configurations and supports communication protocols such as LonWorks TP/FT-10 and Modbus TCP/IP, all housed in a NEMA 4X rated enclosure.

Disponibile in:
US
Richiedi un preventivo
E34-208800-R05-X-KIT-NS Honeywell, Alimentazione
Honeywell

E34-208800-R05-X-KIT-NS

CLASS 3400 SUBMETER - NO SENSORS, 3 Phase, 800 A, 120/208-240 V AC

Su richiesta

The Class 3400 submeter is engineered for accurate energy monitoring in 3-phase configurations, featuring a current capacity of 800 A and voltage ratings of 120/208-240 V AC. It is compliant with ANSI C12.20 and UL/CUL standards, ensuring reliable performance in commercial and industrial environments. This model does not include current sensors, but it supports dual protocol communications, facilitating simultaneous connections to two energy monitoring systems. Notably, it features an advanced 4-line LCD display with backlighting for enhanced readability. The device operates effectively in a wide temperature range, from -4 °F to 122 °F (-20 °C to 50 °C), and can handle humidity levels up to 95% non-condensing. The submeter's robust NEMA 4X enclosure ensures durability in various settings, making it suitable for demanding applications. Additional options such as an expanded feature pack for load control can be integrated to enhance functionality. With an accuracy of ±1% across the full load range, the Class 3400 provides precise measurements critical for energy management and monitoring.

Disponibile in:
US
Richiedi un preventivo
E32-600100-MBAC-SPSCS Honeywell, Alimentazione
Honeywell

E32-600100-MBAC-SPSCS

CLASS 3200 SUBMETER, 1 or 2 Phase, 100 A, 347/600 V AC

Su richiesta

The Class 3200 (H32) Smart Meter is equipped with RS-485 communications and supports multiple meter unit (MMU) configurations. It facilitates simultaneous communication with up to two energy monitoring systems, making it suitable for integration with Building Automation Systems (BAS) and various energy monitoring or billing programs as well as Measurement and Verification (M&V) reporting tools.This device operates within a temperature range of -4 °F to 122 °F (-20 °C to 50 °C) and can function under relative humidity levels of up to 95% non-condensing. Its compact dimensions include an overall width of 6.5 inches (166 mm), height of 7.8 inches (198 mm), and depth of 3.4 inches (86 mm), with a total weight of 7.34 lbs. The submeter can process both single-phase and two-phase configurations and includes two solid-core current sensors.The Class 3200 meter provides a 4-line LCD display with backlight for clear visibility of data and accuracy within ±1% across the load range of 1% to 100% of rated capacity. It supports input voltage configurations of 3 or 4 wire and operates at frequencies of 50 Hz or 60 Hz. Notably, the meter's communication protocols include BACnet MS/TP, enhancing its capability for modern energy management applications.

Disponibile in:
US
Richiedi un preventivo
E34-4001600R01-SPKIT-NS Honeywell, Alimentazione
Honeywell

E34-4001600R01-SPKIT-NS

CLASS 3400 SUBMETER - NO SENSORS, 1 or 2 Phase, 1600 A, 230/400 V AC

Su richiesta

The Class 3400 (H34) Smart Meters incorporate advanced dual protocol communications, facilitating simultaneous interaction with two energy monitoring systems, including Building Automation Systems (BAS) for energy monitoring, billing, and Measurement & Verification (M&V) reporting tools. This model is equipped with an advanced 4-line LCD display, ensuring clear visibility of data. It supports RS485 and Ethernet communication protocols, enhancing connectivity options. With the ability to handle a maximum current of 1600 A, the meter is suitable for both single-phase and two-phase configurations. It features no built-in current sensors and operates within a broad temperature range of -4 °F to 122 °F (-20 °C to 50 °C), with a maximum operating humidity of 95% non-condensing. The device adheres to ANSI C12.20 and UL/CUL standards, ensuring compliance with relevant regulations. Furthermore, the Class 3400 includes options for expanded functionalities, such as load control and two pulse outputs for kWh and kVARh monitoring. The enclosure is rated NEMA 4X, providing protection against environmental factors.

Disponibile in:
US
Richiedi un preventivo
E34-480200-R06XSPKIT-NS Honeywell, Alimentazione
Honeywell

E34-480200-R06XSPKIT-NS

CLASS 3400 SUBMETER - NO SENSORS, 1 or 2 Phase, 200 A, 277/480 V AC

Su richiesta

The Class 3400 Smart Meters are equipped with advanced dual protocol communication capabilities, facilitating simultaneous connections to two distinct energy monitoring systems. This feature supports integration with building automation systems for energy monitoring and billing, as well as measurement and verification reporting tools. The optional expanded feature package enhances the product with built-in load control functionalities and two pulse outputs for kWh and kVARh measurement.Featuring a clear 4-line LCD display with a backlight, the device ensures visibility and ease of use in various lighting conditions. It supports RS485 and Ethernet communication protocols, aligning with industry standards for effective data transmission.The meter adheres to ANSI C12.20 regulations and is UL/CUL listed, ensuring compliance with safety and performance standards. It operates within a temperature range of -4 °F to 122 °F (-20 °C to 50 °C) and can handle up to 95% non-condensing humidity, making it suitable for a variety of commercial and industrial applications.With an overall width of 6.5 inches (166 mm), height of 7.8 inches (198 mm), and depth of 3.4 inches (86 mm), the Class 3400 is designed for easy installation. It has a current rating of 200 A and a voltage input configuration of 277/480 V AC with support for both 3 and 4 wire setups. The accuracy is rated at ±1% across a load range from 1% to 100% of its capacity, ensuring reliable performance.

Disponibile in:
US
Richiedi un preventivo
E20-6003200J-D-KIT-NS Honeywell, Alimentazione
Honeywell

E20-6003200J-D-KIT-NS

CLASS 2000 SUBMETER - NO SENSORS, 3 Phase, 3200 A, 347/600 V AC

Su richiesta

The Class 2000 Submeter is designed for three-phase power monitoring, delivering accurate kW and kWh data. With a maximum current rating of 3200 A and operational voltage of 347/600 V AC, this meter is suitable for various commercial and industrial applications. It operates within a temperature range of -4 °F to 122 °F (-20 °C to 50 °C) and maintains accuracy within ±1% across the full load range. Utilizing a split-core current sensor type, this device does not include current sensors and is compliant with ANSI C12.20 and UL/CUL standards. The enclosure is made of JIC steel, ensuring durability in demanding environments. The meter features a two-line LCD display for easy readability and supports pulse output communication protocols. With no modem included, the device is tailored for integration with energy analytics systems such as WEBs-AX and E-mon Energy Software, making it an effective choice for monitoring electrical usage in diverse settings.

Disponibile in:
US
Richiedi un preventivo