1 / 1
thumbnail

Descrizione

Attivo maturo
This device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having backlit LCD display of 128 by 128 pixels. The meter measures active energy as per accuracy class Class 0.5S complying to IEC 62053-22 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent & Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion and Individual harmonics up to 31st Harmonic order. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 80 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. it supports up to 13 different types of wiring schemes under Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. It is having RS485 communication port over Modbus RTU protocol. The meter can be upgraded with optional add on IO modules for WAGES monitoring. These module comes with either two channels each of digital inputs and outputs or analog inputs and outputs. This version can be configured for 23 different types of alarms stored in 40 registers. Product dimensions are as follows: width 3.78 in (96 mm), depth 2.16 in (54 mm), height 3.78 in (96 mm) and product weight 10.58 oz (300 g).
Country of Origin
IN
Part Number
METSEPM2230
Tariff Code
90283090
EAN
3606480800184
UNSPSC
41113708
€261.00
net
€290.00
Spedizione da:
€40.00
1
Metodi di pagamento:
Migliore offerta da:
DEFornitore Automa.Net di fiducia
Disponibilità:
1 pz.
Disponibile
Aggiornato il: 22-11-2024
Garanzia:
24 mesi
Consegna stimata:
05-09 dicembre a Regno Unito
Condizione:
Rinnovato
Rinnovato - Un articolo rinnovato ispezionato, pulito e riparato per essere completamente funzionante dal produttore o da un tecnico certificato. L'articolo è in eccellenti condizioni e pienamente operativo.
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Complementary

Network Frequency
60 Hz || 50 Hz
Communication Port Support
screw terminal block RS485
Power Quality Analysis
total harmonic distortion || up to the 31st harmonic
Height
96 mm
Measurement Voltage
35-480 V AC 50/60 Hz between phases || 20-277 V AC 50/60 Hz between phase and neutral || 480-999000 V AC 50/60 Hz with external VT
Sampling Rate
64 samples/cycle
Maximum Power Consumption In W
3.3 W power lines (AC)) || 3.3 W 277 V power lines (DC))
Number Of Outputs
0
User Language
Russian || French || Portuguese || English || Spanish || Chinese || German
Product Certifications
CE IEC 61010-1 || cULus UL 61010-1 || cULus CSA C22.2 No 61010-1 || RCM || EAC || C-tick
Type Of Measurement
apparent power min/max, total || active and reactive power min/max, total || current min/max, avg || voltage min/max, avg || frequency min/max, avg || total current harmonic distortion THD (I) per phase || total voltage harmonic distortion THD (U) per phase || power factor min/max, avg || apparent energy total || active and reactive energy total
Communication Port Protocol
Modbus RTU 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires 2500 V
Frequency Measurement Range
45-65 Hz
Communication Service
remote monitoring
Display Resolution
128 x 128 pixels
Number Of Inputs
0
Material
polycarbonate
Net Weight
300 g
Tamperproof Of Settings
protected by access code
Provided Equipment
1 x Installation guide
Depth
total 76.09 mm || embedded 61.64 mm
Measurement Current
5-6000 mA
Local Signalling
Red LED output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh) || Green LED module operation and integrated communication
Connections - Terminals
current transformer screw connection bottom) 6 || voltage inputs screw connection top) 4
Information Displayed
demand current past value) || demand current present value) || demand power past value) || demand power present value) || voltage || current || frequency || energy consumption || harmonic distortion || power factor || active power || apparent power || reactive power || unbalanced in % || harmonic amplitude
Electrical Insulation Class
double insulation || class II
Control Type
4 x button
Function Available
real time clock
Flame Retardance
V-0 conforming to UL 94
[Us] Rated Supply Voltage
80...277 V AC 45...65 Hz +/- 10 % || 100...277 V DC +/- 10 %
Mounting Mode
clip-on
Measurement Accuracy
apparent power +/- 0.5 % || active energy +/- 0.5 % || reactive energy +/- 1 % || active power +/- 0.5 % || voltage +/- 0.5 % || power factor +/- 0.01 || current +/- 0.5 % || frequency +/- 0.05 %
Mounting Support
framework
Compatibility Code
PM2230
Refresh Time
configurable from 1 to 60 min
Data Recording
energy consumption logs || power logs || time stamping || min/max for 8 parameters
Line Rated Current
5 A || 1 A
Cybersecurity
enable/disable communication ports
Display Colour
monochrome
Analogue Input Type
current (impedance <= 0.3 mOhm) || voltage (impedance > 5 MOhm)
Mounting Position
vertical
Width
96 mm
Display Type
Backlit LCD
Measurement Category
category III 480-480 V || category II 480-600 V
Device Application
power monitoring || sub billing
Metering Type
calculated neutral current || active power P, P1, P2, P3 || current I, I1, I2, I3 || peak demand power PM, QM, SM || voltage U, U21, U32, U13, V, V1, V2, V3 || peak demand currents || reactive power Q, Q1, Q2, Q3 || demand power P, Q, S || unbalance current || active, reactive, apparent energy (signed, four quadrant) || apparent power S, S1, S2, S3
Accuracy Class
class 1 reactive energy IEC 62053-24 || class 0.5S active energy IEC 62053-22 || class 5 harmonic distorsion (I THD & U THD)
Maximum Power Consumption In Va
8 VA 277 V AC

Environment

Ambient Air Temperature For Operation
-10-60 °C
Electromagnetic Compatibility
electrostatic discharge conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test conforming to IEC 61000-4-4 || surge immunity test conforming to IEC 61000-4-5 || conducted RF disturbances conforming to IEC 61000-4-6 || magnetic field at power frequency conforming to IEC 61000-4-8 || voltage dips and interruptions immunity test conforming to IEC 61000-4-11 || emission tests conforming to FCC Part 15 class A
Pollution Degree
2
Ambient Air Temperature For Storage
-25-70 °C
Relative Humidity
5-95 % 50-50 °C
Service Life
7 year(s)
Ip Degree Of Protection
front IP54 IEC 60529 || body IP30 IEC 60529
Overvoltage Category
III
Operating Altitude
<= 6561.68 ft (2000 m)

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1510004
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
China Rohs Regulation
X
Circularity Profile
ENVEOLI1510004
Eu Rohs Directive
Compliant with Exemptions

Specifications

Product Or Component Type
power meter
Product Name
EasyLogic PM2200
Range
EasyLogic
Device Short Name
PM2230

Modelli CAD

traceparts
traceparts
Scaricare