safety module, Harmony XPS, zero speed monitoring with time delay, 24V AC or DC, screw
XPSUVN11AP
XPSUVN11AP
XPSUVN11AP
XPSUVN11AP
XPSUVN11AP
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
€317.51
1
Metodi di pagamento:
Un totale di 24 Parts In-Stock da 17 Distributors
Offerta con tempi di consegna del produttore
Spedizione in:1 - 2 Molti giorni lavorativi
Miglior prezzo:
€161.11

Additional Information

Part Number
XPSUVN11AP
UNSPSC
32151705
Tariff Code
8536410050

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1811003EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1811003EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Specifications

Product Certifications
TÜV || cULus
[Us] Rated Supply Voltage
24 V AC - 15...10 % || 24 V DC - 20...20 %
Range Of Product
Harmony Safety Automation
Product Or Component Type
safety module
Safety Module Name
XPSUVN
Number Of Additional Circuits
2 solid state outputs
Output Type
relay, 1 NO, volt-free
Safety Module Application
for zero speed detection
Safety Reliability Data
MTTFd > 30 years ISO 13849-1 || Dcavg = 98.9 % ISO 13849-1 || PFHd = 2.39E-9 1/h ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 2.39E-9 1/h IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 2.39E-9 1/h IEC 61508-1 || SFF > 99% IEC 61508-1 || type = B IEC 61508-1
Function Of Module
monitoring 3-phase motor || monitoring 3-phase motor with star-delta starting || monitoring 3-phase motor with variable number of poles || monitoring 3-phase motor with variable number of poles and star-delta starting || monitoring dc motor || monitoring servo motor || monitoring 3-phase motor supplied by variable speed drive || monitoring 3-phase motor supplied by servo drive || controlling enegization to open of guard switch type XCSE, XCSLE, XCSLF, XCST
Safety Level
can reach PL e/category 3 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508

Complementary

Height
100 mm
[Ith] Conventional Free Air Thermal Current
6 A NO relay output circuit
Mounting Support
35 mm symmetrical DIN rail
Power Consumption In W
2.0 W
Minimum Output Voltage
5 V relay output
Minimum Output Current
10 mA relay output
Time Delay
0.5 s || 1 s || 2 s || 3 s || 5 s || 8 s || 12 s || 20 s || 35 s || 60 s
Associated Fuse Rating
6 A gG relay output IEC 60947-1
Local Signalling
LED green power power ON || LED red error error || LED yellow state status || LED yellow L12 input line comparison || LED yellow L32 input line comparison
[Uimp] Rated Impulse Withstand Voltage
4 kV II IEC 60947-1
Net Weight
0.2 kg
Standards
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard
[Ui] Rated Insulation Voltage
690 V phase to phase 2)IEC 60947-1 || 400 V phase to earth 2)IEC 60947-1
[Ie] Rated Operational Current
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact
Power Consumption In Va
5.5 VA
Input Voltage
690 V
Connections - Terminals
removable screw terminal block solid or flexible 0.2...2.5 mm² || removable screw terminal block flexible with ferrule 0.25...2.5 mm² single conductor || removable screw terminal block solid or flexible 0.2...1.5 mm² twin conductor || removable screw terminal block flexible with ferrule 2 x 0.25...1 mm² without cable end, with bezel || removable screw terminal block flexible with ferrule 2 x 0.5...1.5 mm² with cable end, with bezel
Width
22.5 mm
Depth
120 mm
Input Detection Threshold
50 mV || 65 mV || 85 mV || 110 mV || 140 mV || 180 mV || 230 mV || 300 mV || 400 mV || 500 mV

Environment

Ambient Air Temperature For Operation
-25-55 °C
Ip Degree Of Protection
IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Relative Humidity
5-95 % non-condensing