3M

7624-T-110

3M™ Cold Shrink QT-III Termination Kit 7624-T-110, Tape/Wire/UniShield®Shielding, 5-15 kV, Insulation OD 0.83-1.53 in, 3/kit
7624-T-110
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Manufacturer Catalog Number
7000006102
Breakout Boot
No
Cable Insulation Outside Diameter Range (Metric)
0.83-1.53 in
Cable Shielding
Wire Shield|| UniShield®|| Tape Shield
Conductor Size by Voltage
(5 kV) 500-750 kcmil, (8 kV) 350-700 kcmil, (15 kV) 4/0 AWG-500 kcmil
Indoor/Outdoor
Indoor Non-skirted
Insulation Level
100%|| 133%
Insulation Outer Diameter (Imperial)
0.83 in|| 0.92 in|| 0.85 in|| 0.86 in|| 0.87 in|| 0.88 in|| 0.89 in|| 0.9 in|| 0.91 in|| 1 in|| 0.93 in|| 0.94 in|| 0.95 in|| 0.96 in|| 0.97 in|| 0.98 in|| 0.99 in|| 1.01 in|| 1.17 in|| 1.02 in|| 1.03 in|| 1.04 in|| 1.05 in|| 1.06 in|| 1.07 in|| 1.08 in|| 1.09 in|| 1.1 in|| 1.11 in|| 1.12 in|| 1.13 in|| 1.14 in|| 1.15 in|| 1.16 in|| 0.84 in|| 1.18 in|| 1.2 in|| 1.28 in|| 1.21 in|| 1.22 in|| 1.23 in|| 1.24 in|| 1.25 in|| 1.26 in|| 1.27 in|| 1.36 in|| 1.29 in|| 1.3 in|| 1.31 in|| 1.32 in|| 1.33 in|| 1.34 in|| 1.35 in|| 1.37 in|| 1.19 in|| 1.38 in|| 1.39 in|| 1.4 in|| 1.41 in|| 1.42 in|| 1.43 in|| 1.44 in|| 1.45 in|| 1.46 in|| 1.47 in|| 1.48 in|| 1.49 in|| 1.5 in|| 1.51 in|| 1.52 in|| 1.53 in
Insulation Outer Diameter (Metric)
21.082 mm|| 23.368 mm|| 21.59 mm|| 21.844 mm|| 22.098 mm|| 22.352 mm|| 22.606 mm|| 22.86 mm|| 23.114 mm|| 25.4 mm|| 23.622 mm|| 23.876 mm|| 24.13 mm|| 24.384 mm|| 24.638 mm|| 24.892 mm|| 25.146 mm|| 25.654 mm|| 29.718 mm|| 25.908 mm|| 26.162 mm|| 26.416 mm|| 26.67 mm|| 26.924 mm|| 27.178 mm|| 27.432 mm|| 27.686 mm|| 27.94 mm|| 28.194 mm|| 28.448 mm|| 28.702 mm|| 28.956 mm|| 29.21 mm|| 29.464 mm|| 21.336 mm|| 29.972 mm|| 30.48 mm|| 32.512 mm|| 30.734 mm|| 30.988 mm|| 31.242 mm|| 31.496 mm|| 31.75 mm|| 32.004 mm|| 32.258 mm|| 34.544 mm|| 32.766 mm|| 33.02 mm|| 33.274 mm|| 33.528 mm|| 33.782 mm|| 34.036 mm|| 34.29 mm|| 34.798 mm|| 30.226 mm|| 35.052 mm|| 35.306 mm|| 35.56 mm|| 35.814 mm|| 36.068 mm|| 36.322 mm|| 36.576 mm|| 36.83 mm|| 37.084 mm|| 37.338 mm|| 37.592 mm|| 37.846 mm|| 38.1 mm|| 38.354 mm|| 38.608 mm|| 38.862 mm
Insulation Rejacketing
No
Lug/Stem Connector Included in Kit
No
Manufacturing Origin
USA
Maximum Installed Length
12.00 in
Number of Conductors
1
Voltage
15 kV|| 350 kV|| 5 kV|| 8 kV
Voltage Application
Medium Voltage