1SAZ711201R1035

T16-4.2 Thermal Overload Relay 3.1 ... 4.2 A
1SAZ711201R1035
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up

Dimensions

Product Net Width
45 mm
Product Net Height
76.7 mm
Product Net Depth / Length
53.5 mm
Product Net Weight
0.1 kg

Technical

Setting Range
3.1 ... 4.2 A
Rated Operational Voltage
Auxiliary Circuit 600 V AC/DCMain Circuit 690 V AC
Rated Operational Current (Ie)
4.2 A
Rated Frequency (f)
Auxiliary Circuit 50 HzAuxiliary Circuit 60 HzAuxiliary Circuit DCMain Circuit 50 HzMain Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kVMain Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Number of Poles
3
Number of Auxiliary Contacts NC
1
Number of Auxiliary Contacts NO
1
Number of Protected Poles
3
Conventional Free-air Thermal Current (Ith)
Auxiliary Circuit NC 6 AAuxiliary Circuit NO 4 A
Rated Operational Current AC-15 (Ie)
(120 V) NC 3 A(120 V) NO 0.5 A(240 V) NC 3 A(240 V) NO 0.5 A(400 V) NC 0.75 A(400 V) NO 0.5 A(500 V) NC 0.75 A(500 V) NO 0.5 A
Rated Operational Current DC-13 (Ie)
(125 V) NC 0.55 A(125 V) NO 0.55 A(24 V) NC 1.25 A(24 V) NO 1.25 A(250 V) NC 0.27 A(250 V) NO 0.27 A(500 V) NC 0.15 A(500 V) NO 0.15 A(60 V) NC 0.55 A(60 V) NO 0.55 A
Degree of Protection
IP20
Pollution Degree
3
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Flexible 1/2x 0.75 ... 1 mm²Flexible 1/2x 1 ... 2.5 mm²Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 4 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm²Flexible 1/2x 0.75 ... 4 mm²Solid 1/2x 0.75 ... 1.5 mm²Solid 1/2x 1.5 ... 4 mm²Stranded 1/2x 1 ... 4 mm²
Tightening Torque
Auxiliary Circuit 1 ... 1.2 N·mMain Circuit 1.1 ... 1.5 N·m
Wire Stripping Length
Auxiliary Circuit 9 mmMain Circuit 12 mm
Recommended Screw Driver
Main Circuit Pozidriv 2
Power Loss
at Rated Operating Conditions per Pole 1.1 ... 2.0 W
Suitable For
B6BC6B7BC7VB6VBC6VB7VBC7MC1MC2AS09AS12AS16
Standards
IEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 60947-5-1UL 60947-1UL 60947-4-1

Classifications

Object Classification Code
F
ETIM 4
EC000106 - Thermal overload relay
ETIM 5
EC000106 - Thermal overload relay
EClass
V11.0 : 27371501
IDEA Granular Category Code (IGCC)
5366 >> Thermal overload relay
E-Number (Finland)
3706145
E-Number (Sweden)
3212066

Environmental

Ambient Air Temperature
Operation -25 ... +60 °COperation Compensated -25 ... +60 °CStorage -50 ... +80 °C
Ambient Air Temperature Compensation
Yes
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 22g
Resistance to Vibrations acc. to IEC 60068-2-6
3g / 3 ... 150 Hz
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Technical UL/CSA

Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Contact Rating UL/CSA
(NC:) B600(NC:) Q600(NO:) Q600(NO:) D300
Connecting Capacity Main Circuit UL/CSA
Flexible 1/2x 18-12 AWGStranded 1/2x 18-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Flexible 1/2x 18-12 AWGStranded 1/2x 18-12 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 9 ... 11 in·lbMain Circuit 9 ... 13 in·lb

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900