ABB

1SAM340000R1009

MS132-6.3T Circuit Breaker for Primary Transformer Protection 4.0 ... 6.3 A
1SAM340000R1009
1SAM340000R1009
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
A total of 336 Parts In-Stock from 17 Distributors
Offer with manufacturer lead time
Ships in:On Request
Best price:
€30.63

Additional Information

Part Number
1SAM340000R1009
UNSPSC
39121601
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power circuit-breaker for trafo/generator/installation protection
Class Code : EC000228
Version : 7

Dimensions

Product Net Width
45 mm
Product Net Height
90 mm
Product Net Depth / Length
86.75 mm
Product Net Weight
0.265 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)
(230 V AC) 100 kA(400 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(400 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)
126 A
Setting Range
4.0 ... 6.3 A
Rated Operational Voltage
Main Circuit 690 V AC
Rated Operational Current (Ie)
6.3 A
Rated Frequency (f)
Main Circuit 50 HzMain Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Power Loss
at Rated Operating Conditions per Pole 0.7 ... 1.8 W
Number of Poles
3
Conventional Free-air Thermal Current (Ith)
Main Circuit 6.3 A
Degree of Protection
Housing IP20Main Circuit Terminals IP10
Pollution Degree
3
Electrical Durability
50000 cycle
Mechanical Durability
100000 cycle
Terminal Type
Screw Terminals
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²Flexible 1/2x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 4 mm²
Tightening Torque
Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length
Main Circuit 9 mm
Recommended Screw Driver
M3.5Pozidriv 2
Mounting Position
1 ... 6
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance
Electrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 9 mmOther Device Same Type, Vertical 150 mm
Actuator Type
Rotary Handle
Contact Position Indication
ON / OFF / TRIP
Standards
IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1

Classifications

Object Classification Code
F
ETIM 4
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
ETIM 5
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
EClass
V11.0 : 27370409
IDEA Granular Category Code (IGCC)
4864 >> Enclosed 3 Pole Circuit Breakers
E-Number (Finland)
3707278
E-Number (Sweden)
3110415

Environmental

Ambient Air Temperature
Around the Enclosure 0 ... +40 °COperation -25 ... +70 °COperation Compensated -25 ... +60 °CStorage -50 ... +80 °C
Ambient Air Temperature Compensation
Yes
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6
5g / 3 ... 150 Hz
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Technical UL/CSA

Short-Circuit Current Rating (SCCR)
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Horsepower Rating UL/CSA
(120 V AC) Single Phase 0.25 Hp(220 ... 240 V AC) Single Phase 0.5 Hp
Full Load Amps Motor Use
(120 V AC) Single Phase 6.3 A(220 ... 240 V AC) Single Phase 6.3 A
Locked Rotor Amps
(120 V AC) Single Phase 37.8 A(220 ... 240 V AC) Single Phase 37.8 A
Connecting Capacity Main Circuit UL/CSA
Flexible 1/2x 16-12 AWGStranded 1/2x 16-12 AWG
Tightening Torque UL/CSA
Main Circuit 10 ... 12 in·lb

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85362010