ABB

1SDA067431R1

XT1S 160 TMD 50-500 3p F F
1SDA067431R1
1SDA067431R1
1SDA067431R1
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
€119.76
1
Payment methods:
A total of 233 Parts In-Stock from 12 Distributors

Additional Information

Part Number
1SDA067431R1
UNSPSC
39120000
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power circuit-breaker for trafo/generator/installation protection
Class Code : EC000228
Version : 7

Additional Information

Circuit Breaker Type to be Associated
Power Distribution
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour8000 cycle
Mechanical Durability
240 cycles per hour25000 cycle
Number of Poles
3
Opening Time
CB with SOR 15 msCB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3.7 W
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Rated Current (In)
50 A
Rated Frequency (f)
50 / 60 Hz
Rated Voltage (Ur)
690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 63.75 kA(230 V AC) 63.75 kA(240 V AC) 63.75 kA(380 V AC) 50 kA(415 V AC) 37.5 kA(440 V AC) 25 kA(500 V AC) 18 kA(525 V AC) 17.5 kA(690 V AC) 5 kA(250 V DC) 2 Poles in Series 50 kA(500 V DC) 3 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA(230 V AC) 85 kA(240 V AC) 85 kA(380 V AC) 50 kA(415 V AC) 50 kA(440 V AC) 50 kA(500 V AC) 36 kA(525 V AC) 35 kA(690 V AC) 8 kA(250 V DC) 2 Poles in Series 50 kA(500 V DC) 3 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)
160 A
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
35...50 A
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Version
F
CAD Dimensional Drawing
1SDH001295R0008

Dimensions

Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg

ABB EcoSolutions

ABB EcoSolutions
Yes

Eco Transparency

Environmental Product Declaration - EPD
9AKK108468A1890

Classifications

ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
EClass
V11.1 : 27370409

Environmental

Environmental Information
9AKK107991A8215 9AKK108467A6707
REACH Declaration
9AKK108466A1425
RoHS Information
9AKK108466A1424
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
d8b419b4-3733-4ae4-8a91-4f84863049e0 Italy (IT)
Simplified SCIP
b61537aa-9439-4228-8a02-f85a1924e991 Germany (DE)fcbdede8-6af9-4bdd-b2f0-4f4d7a753ea0 Denmark (DK)1c5857dc-2613-44ac-ba65-234df54018a0 Germany (DE)399aba8f-736e-432c-8ffd-5f1cc537b748 Croatia (HR)61cca731-850a-44e7-af52-c7013fc97300 Czech Republic (CZ)5b14a9a3-4dbb-4fc2-920d-c934de09fbd9 Poland (PL)2222484c-32d6-4b08-b67f-f04af6e360e6 Netherlands (NL)4f3eb8da-4047-4f3a-91b9-39e159c24072 Netherlands (NL)9948e8d9-aed0-47b1-9f52-59670ea55e2f Estonia (EE)0392203b-40aa-4cf9-b370-a8600173f82b Greece (GR)91937007-a34c-4126-8f1d-43e8456f03b2 Portugal (PT)db736ba5-fc8d-40eb-abbe-50e76637f158 Bulgaria (BG)33a52e53-2d43-4dde-a4e1-f19f8b48a80e Sweden (SE)af23864e-f9c0-4acf-b523-116cd3c089b2 Poland (PL)6ed718fe-1cee-409d-8787-6cce870b3048 Netherlands (NL)6e52a94e-28c0-4c6c-b151-0fefe424e7b9 Spain (ES)8d786b29-969c-4cae-8100-1de45cca1d75 Poland (PL)2d03f65a-0e93-47d9-9a8e-ccee92f7939a Norway (NO)1d7952a1-da7d-4aba-b587-fad0428ef996 Finland (FI)8f7e52f8-fca7-4fba-8a8e-5e478d6ccbfe Netherlands (NL)8d786b29-969c-4cae-8100-1de45cca1d75 Poland (PL)2d03f65a-0e93-47d9-9a8e-ccee92f7939a Norway (NO)1d7952a1-da7d-4aba-b587-fad0428ef996 Finland (FI)8f7e52f8-fca7-4fba-8a8e-5e478d6ccbfe Netherlands (NL)b61537aa-9439-4228-8a02-f85a1924e991 Germany (DE)fcbdede8-6af9-4bdd-b2f0-4f4d7a753ea0 Denmark (DK)1c5857dc-2613-44ac-ba65-234df54018a0 Germany (DE)399aba8f-736e-432c-8ffd-5f1cc537b748 Croatia (HR)61cca731-850a-44e7-af52-c7013fc97300 Czech Republic (CZ)5b14a9a3-4dbb-4fc2-920d-c934de09fbd9 Poland (PL)2222484c-32d6-4b08-b67f-f04af6e360e6 Netherlands (NL)4f3eb8da-4047-4f3a-91b9-39e159c24072 Netherlands (NL)9948e8d9-aed0-47b1-9f52-59670ea55e2f Estonia (EE)0392203b-40aa-4cf9-b370-a8600173f82b Greece (GR)91937007-a34c-4126-8f1d-43e8456f03b2 Portugal (PT)062277d9-49d5-444c-9bca-83e92e3f5566 Sweden (SE)e38d4261-32ad-4cfd-b2c4-dfaa3eedc7be Germany (DE)3a5a980f-7795-4e1c-8126-4cb638caa0b1 Germany (DE)53202e0e-c61a-417c-9f00-04f7235421ef France (FR)6ed718fe-1cee-409d-8787-6cce870b3048 Netherlands (NL)6e52a94e-28c0-4c6c-b151-0fefe424e7b9 Spain (ES)0f021f04-9872-4a7f-8880-e71db5b2d6db Netherlands (NL)db736ba5-fc8d-40eb-abbe-50e76637f158 Bulgaria (BG)33a52e53-2d43-4dde-a4e1-f19f8b48a80e Sweden (SE)0f021f04-9872-4a7f-8880-e71db5b2d6db Netherlands (NL)af23864e-f9c0-4acf-b523-116cd3c089b2 Poland (PL)07cc18df-e9e3-4057-889d-0896c8a1af0d France (FR)062277d9-49d5-444c-9bca-83e92e3f5566 Sweden (SE)e38d4261-32ad-4cfd-b2c4-dfaa3eedc7be Germany (DE)3a5a980f-7795-4e1c-8126-4cb638caa0b1 Germany (DE)53202e0e-c61a-417c-9f00-04f7235421ef France (FR)07cc18df-e9e3-4057-889d-0896c8a1af0d France (FR)

Circular Value

Circular Design Principles Recyclability Rate
Design for Closing Resource Loops - Standard EN45555 - 60.9 %
Conflict Minerals Reporting Template (CMRT)
9AKK108467A5658
End of Life Instructions
9AKK108468A2347
Group Waste to Landfill Target
UL 2799 Zero Waste To Landfill Validation available
Toxic Substances Control Act - TSCA
9AKK108467A8326

Ordering

Order Code US and Canada
XT1SE3050AFF000XXX
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090