ABB

2CSF204101R1250

F204 A-25/0.03 Residual Current Circuit Breaker 4P A type 30 mA
2CSF204101R1250
2CSF204101R1250
2CSF204101R1250
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
A total of 991 Parts In-Stock from 21 Distributors

Installation

Instructions and Manuals
9AKK107991A6127

Dimensions

Width in Number of Modular Spacings
4
Product Net Width
0.070 m
Product Net Height
0.085 m
Product Net Depth / Length
0.069 m
Product Net Weight
0.360 kg
Built-In Depth (t2)
69 mm

Technical

Standards
IEC/EN 61008UL 1053
Type of Residual Current
A type
Rated Voltage (Ur)
230/400 V
Rated Operational Voltage
230 / 400 V AC
Rated Insulation Voltage (Ui)
500 V
Rated Impulse Withstand Voltage (Uimp)
4 kV
Input Voltage Type
AC
Rated Current (In)
25 A
Rated Residual Current
30 mA
Rated Conditional Short-Circuit Current (Inc)
10 kA
Rated Service Short-Circuit Breaking Capacity (Ics)
1 kA
Leakage Current Type
A
Rated Frequency (f)
50 … 60 Hz
Power Loss
at Rated Operating Conditions per Pole 1.3 W
Power Supply Connection
Arbitrary
Electrical Endurance
10000 cycle
Number of Poles
4
Operating Characteristic
Instantaneous
Position of Neutral Terminals
Right
Mounting Type
DIN-Rail
Options Provided
None
Accessories Available
Yes
Connecting Capacity
Busbar 10 mm²Rigid 25 ... 25 mm²Flexible 25 ... 25 mm²
Rated Cross-Section
4 - Multi-Wired 0...25 mm²1 - Solid-Core 25...25 mm²

Eco Transparency

Environmental Product Declaration - EPD
9AKK108467A3700

Classifications

ETIM 9
EC000003 - Residual current circuit breaker (RCCB)
EPLAN Function Definition
Ground fault current circuit-breaker / Ground fault current circuit breakers, 8 connection points / Ground fault current circuit breaker, four-pole 1 2 3 4 5 6 7 8
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B
Business To Consumer
CN8
85363030
EClass
V11.0 : 27142201
Object Classification Code
F

Environmental

Ambient Temperature
-25...55 °C
Ambient Air Temperature
Operation -25...55 °C
Degree of Protection
IP2X
Pollution Degree
2
Resistance to Vibrations acc. to IEC 60068-2-6
0.1 mm or 1 g - 20 cycles at 5…150…5 Hz
Resistance to Shock acc. to IEC 60068-2-27
25g 2 shocks 13 ms
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Information
9AKK106713A5602
REACH Declaration
9AKK108467A9482
Environmental Information
Refer to RoHS
Conflict Minerals Reporting Template (CMRT)
9AKK108468A3363

Circular Value

Circular Design Principles Recyclability Rate
Design for Closing Resource Loops - Standard EN45555 - 52,5 %
Sustainable Material Content
0 %
End of Life Instructions
9AKK108468A4361

Technical UL/CSA

Maximum Operating Voltage UL/CSA
480Y / 277 V AC
Short-Circuit Current Rating (SCCR)
30 mA

Ordering

Minimum Order Quantity
1 piece
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
0.415 kg
E-Number (Finland)
3259425
E-Number (Sweden)
2160124