ABB

AF146B-30-22-12

AF146B-30-22-12 Contactor
AF146B-30-22-12
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Dimensions

Product Net Width
90 mm
Product Net Depth / Length
126 mm
Product Net Height
150 mm
Product Net Weight
1.55 kg

Technical

Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 225 A(1000 V) 55 °C 200 A(1000 V) 60 °C 200 A(1000 V) 70 °C 175 A(690 V) 40 °C 225 A(690 V) 55 °C 200 A(690 V) 60 °C 200 A(690 V) 70 °C 175 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 146 A(440 V) 55 °C 130 A(500 V) 55 °C 130 A(690 V) 55 °C 93 A(1000 V) 55 °C 60 A(380 / 400 V) 55 °C 146 A(220 / 230 / 240 V) 55 °C 146
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 146 A(440 V) 60 °C 146 A(500 V) 60 °C 130 A(690 V) 60 °C 93 A(1000 V) 60 °C 54 A(380 / 400 V) 60 °C 146 A(220 / 230 / 240 V) 60 °C 146 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW(440 V) 90 kW(500 V) 90 kW(690 V) 90 kW(1000 V) 75 kW(380 / 400 V) 75 kW(220 / 230 / 240 V) 45 kW
Rated Operational Power AC-3e (Pe)
(415 V) 75 kW(440 V) 90 kW(500 V) 90 kW(690 V) 90 kW(1000 V) 75 kW(380 / 400 V) 75 kW(220 / 230 / 240 V) 45 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 225 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 200 A(110 V) 2 Poles in Series, 60 °C 200 A(110 V) 2 Poles in Series, 70 °C 175 A(110 V) 3 Poles in Series, 40 °C 200 A(110 V) 3 Poles in Series, 60 °C 200 A(110 V) 3 Poles in Series, 70 °C 175 A(175 V) 2 Poles in Series, 40 °C 200 A(175 V) 2 Poles in Series, 60 °C 200 A(175 V) 2 Poles in Series, 70 °C 175 A(220 V) 3 Poles in Series, 40 °C 200 A(220 V) 3 Poles in Series, 60 °C 200 A(220 V) 3 Poles in Series, 70 °C 175 A(260 V) 3 Poles in Series, 40 °C 200 A(260 V) 3 Poles in Series, 60 °C 200 A(260 V) 3 Poles in Series, 70 °C 175 A(72 V) 1-Pole, 40 °C 200 A(72 V) 1-Pole, 60 °C 200 A(72 V) 1-Pole, 70 °C 175 A(72 V) 2 Poles in Series, 40 °C 200 A(72 V) 2 Poles in Series, 60 °C 200 A(72 V) 2 Poles in Series, 70 °C 175 A(72 V) 3 Poles in Series, 40 °C 200 A(72 V) 3 Poles in Series, 60 °C 200 A(72 V) 3 Poles in Series, 70 °C 175 A(90 V) 1 Pole, 40 °C 200 A(90 V) 1 Pole, 60 °C 200 A(90 V) 1 Pole, 70 °C 175 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 48 ... 130 VDC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 4 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 4 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 180 V·APull-in at Max. Rated Control Circuit Voltage DC 150 W
Terminal Type
Main Circuit: Bars

Eco Transparency

Environmental Product Declaration - EPD
1SFC100092D0201

Classifications

Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
EClass
V11.0 : 27371003
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210437

Environmental

RoHS Status
Following EU Directive 2011/65/EU

Circular Value

ABB EcoSolutions
Yes
Circular Design Principles Recyclability Rate
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
End of Life Instructions
1SFC100112M0001
Group Waste to Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
Improved Resource Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Sustainable Material Content
Recycled Metal - 37 %

Technical UL/CSA

General Use Rating UL/CSA
(600 V AC) 200 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 40 hp(220 ... 240 V AC) Three Phase 50 hp(440 ... 480 V AC) Three Phase 100 hp(550 ... 600 V AC) Three Phase 125 hp

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900