AF40N2-30-11-13
AF40N2-30-11-13 100-250V50/60HZ-DC Contactor
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Dimensions
- Product Net Width
- 67 mm
- Product Net Depth / Length
- 111 mm
- Product Net Height
- 125.5 mm
- Product Net Weight
- 0.99 kg
Technical
- Connecting Capacity Auxiliary Circuit
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 2.5 mm²
- Connecting Capacity Control Circuit
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
- Connecting Capacity Main Circuit
- Flexible with Ferrule 1/2x 4 ... 35 mm²Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²Rigid Stranded 1/2x 6 ... 35 mm²
- Maximum Breaking Capacity
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
- Maximum Electrical Switching Frequency
- (AC-1) 600 cycles per hour(AC-15) 1200 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 1200 cycles per hour(DC-13) 900 cycles per hour
- Maximum Mechanical Switching Frequency
- 3600 cycles per hour
- Minimum Mounting Distance
- Other Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 0 mm
- Mounted Auxiliary Contacts
- 1 NO, 1 NC
- Mounting Position
- 1, 1 +/-30°, 2, 3, 4, 5
- Mounting by Screws (not supplied)
- 2 x M4 or 2 x M6 screws placed diagonally
- Mounting on DIN Rail
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Number of Auxiliary Contacts NC
- 1
- Number of Auxiliary Contacts NO
- 1
- Number of Main Contacts NC
- 0
- Number of Main Contacts NO
- 3
- Number of Poles
- 3
- Operate Time
- Between Coil De-energization and NC Contact Closing 19 ... 105 msBetween Coil De-energization and NO Contact Opening 17 ... 100 msBetween Coil Energization and NC Contact Opening 38 ... 95 msBetween Coil Energization and NO Contact Closing 42 ... 100 ms
- Pollution Degree
- 3
- Power Loss
- at 6 A per Pole 0.1 Wat Rated Operating Conditions AC-1 per Pole 3 Wat Rated Operating Conditions AC-3 per Pole 1 W
- Rated Control Circuit Voltage (Uc)
- 50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
- Rated Frequency (f)
- Auxiliary Circuit 50 / 60 HzControl Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
- Rated Impulse Withstand Voltage (Uimp)
- 6 kV
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 690 Vacc. to IEC 60947-5-1 690 Vacc. to UL/CSA 600 V
- Rated Operational Current AC-1 (Ie)
- (690 V) 40 °C 70 A(690 V) 60 °C 60 A(690 V) 70 °C 50 A
- Rated Operational Current AC-15 (Ie)
- (500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A
- Rated Operational Current AC-3 (Ie)
- (415 V) 60 °C 40 A(440 V) 60 °C 40 A(500 V) 60 °C 35 A(690 V) 60 °C 25 A(380 / 400 V) 60 °C 40 A(220 / 230 / 240 V) 60 °C 40 A
- Rated Operational Current AC-3e (Ie)
- (415 V) 60 °C 40 A(440 V) 60 °C 40 A(500 V) 60 °C 35 A(690 V) 60 °C 25 A(380 / 400 V) 60 °C 40 A(220 / 230 / 240 V) 60 °C 40 A
- Rated Operational Current DC-13 (Ie)
- (24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W(400 V) 0.15 A / 60 W(500 V) 0.13 A / 65 W(600 V) 0.1 A / 60 W
- Rated Operational Power AC-3 (Pe)
- (400 V) 18.5 kW(415 V) 22 kW(440 V) 22 kW(500 V) 22 kW(690 V) 22 kW(380 / 400 V) 18.5 kW(220 / 230 / 240 V) 11 kW
- Rated Operational Power AC-3e (Pe)
- (415 V) 22 kW(440 V) 22 kW(500 V) 22 kW(690 V) 22 kW(380 / 400 V) 18.5 kW(220 / 230 / 240 V) 11 kW
- Rated Operational Voltage
- Auxiliary Circuit 690 VMain Circuit 690 V
- Rated Short-time Withstand Current Low Voltage (Icw)
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 Afor 0.1 s 140 Afor 1 s 100 A
- Standards
- IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
- Terminal Type
- Screw Terminals
- Tightening Torque
- Auxiliary Circuit 1.2 N·mControl Circuit 1.2 N·mMain Circuit 4 N·m
- Wire Stripping Length
- Auxiliary Circuit 10 mmControl Circuit 10 mmMain Circuit 16 mm
Classifications
- EClass
- V11.0 : 27371003
- ETIM 9
- EC000066 - Power contactor, AC switching
- Object Classification Code
- Q
Environmental
- Ambient Air Temperature
- Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
- Climatic Withstand
- Category B according to IEC 60947-1 Annex Q
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 Aacc. to IEC 60947-5-1, Θ = 40 °C 16 A
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
- Maximum Operating Altitude Permissible
- Without Derating 3000 m
- Resistance to Shock acc. to IEC 60068-2-27
- Closed, Shock Direction: A 25 gClosed, Shock Direction: B1 25 gClosed, Shock Direction: B2 15 gClosed, Shock Direction: C1 25 gClosed, Shock Direction: C2 25 gOpen, Shock Direction: A 25 gOpen, Shock Direction: B1 5 gOpen, Shock Direction: B2 15 gOpen, Shock Direction: C1 25 gOpen, Shock Direction: C2 25 g
- Resistance to Vibrations acc. to IEC 60068-2-6
- 5 ... 300 Hz 3 g closed position / 3 g open position
- RoHS Information
- 2CMT2021-006277
- WEEE Category
- Product Not in WEEE Scope
Technical UL/CSA
- Connecting Capacity Control Circuit UL/CSA
- Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
- Connecting Capacity Main Circuit UL/CSA
- Rigid Stranded 1/2x 10-2 AWG
- Continuous Current Rating NEMA
- 45 A
- Full Load Amps Motor Use
- (120 V AC) Single Phase 3 A(200 ... 208 V AC) Three Phase 10 A(220 ... 240 V AC) Three Phase 15 A(240 V AC) Single Phase 7-1/2 A(440 ... 480 V AC) Three Phase 30 A(550 ... 600 V AC) Three Phase 40 A
- General Use Rating UL/CSA
- (600 V AC) 60 A
- Horsepower Rating NEMA
- (115 V AC) Single Phase 3 Hp(200 V AC) Three Phase 10 Hp(230 V AC) Single Phase 7-1/2 Hp(230 V AC) Three Phase 15 Hp(460 V AC) Three Phase 25 Hp(575 V AC) Three Phase 25 Hp
- Maximum Operating Voltage UL/CSA
- Main Circuit 600 V
- NEMA Size
- 2
- Pilot Duty UL/CSA
- A600Q600
- Tightening Torque UL/CSA
- Auxiliary Circuit 11 in·lbControl Circuit 11 in·lbMain Circuit 35 in·lb
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85364900
- Product Main Type
- AF40N2
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther