ABB

AF40N2-30-11-41

AF40N2-30-11-41 24-60V50/60HZ Contactor
AF40N2-30-11-41
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Additional Information

Part Number
AF40N2-30-11-41

Additional Information

Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5Flexible with Insulated Ferrule 2x 0.75 ... 1.5Flexible with Insulated Ferrule 1x 0.75 ... 2.5Rigid 1/2x 1 ... 2.5 m²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 m²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 m²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 m²Rigid 1/2x 1 ... 2.5 m²
Connecting Capacity Main Circuit
Rigid 1/2x 6 ... 3 5 m²Flexible with Ferrule 1/2x 4 ... 35 m²Flexible with Insulated Ferrule 1/2x 4 ... 35 m²
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-5-1, q = 40 °C 16 Aacc. to IEC 60947-4-1, Open Contactors q = 40 °C 105 A
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Maximum Electrical Switching Frequency
AC-1 600 cycles per hourAC-2 / AC-4 150 cycles per hourAC-3 1200 cycles per hourAC-15 1200 cycles per hourDC-13 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Mounted Auxiliary Contacts
1 NO, 1 NC
Mounted Auxiliary Contacts 1st Stack
0 NO, 0 NC
Mounted Auxiliary Contacts 2nd Stack
1 NO, 1 NC
Mounting Position
Max. N.C. built-in and add-on N.C. auxiliary contacts: see accessory fitting details for a 3-pole contactor AF40 ... AF96
Number of Auxiliary Contacts NC
1
Number of Auxiliary Contacts NO
1
Number of Main Contacts NC
0
Number of Main Contacts NO
3
Operate Time
Between Coil De-energization and NC Contact Closing 19 ... 105 msBetween Coil De-energization and NO Contact Opening 17 ... 100 msBetween Coil Energization and NC Contact Opening 38 ... 95 msBetween Coil Energization and NO Contact Closing 42 ... 100 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions AC-1 per Pole 3 Wat Rated Operating Conditions AC-3 per Pole 1 W
Product Main Type
AF40N
Product Name
Block Contactor
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V50 Hz / 60 Hz 24 ... 60 V60 Hz 24 ... 60 VDC Operation -
Rated Frequency (f)
Auxiliary Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
6 kV
Rated Insulation Voltage (Ui)
acc. to UL/CSA 600 Vacc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 70 A(690 V) 60 °C 60 A(690 V) 70 °C 50 A
Rated Operational Current AC-15 (Ie)
(220 / 240 V) 4 A(24 / 127 V) 6 A(500 V) 2 A(690 V) 2 A(400 / 440 V) 3 A
Rated Operational Current AC-3 (Ie)
(220 / 230 / 240 V) 60 °C 40 A(380 / 400 V) 60 °C 40 A(415 V) 60 °C 40 A(440 V) 60 °C 40 A(500 V) 60 °C 35 A(690 V) 60 °C 25 A
Rated Operational Current DC-13 (Ie)
(125 V) 0.55 A / 69 W(24 V) 6 A / 144 W(250 V) 0.27 A / 68 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(220 V) 0.27 A / 60 W(400 V) 0.15 A / 60 W(500 V) 0.13 A / 65 W(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(220 / 230 / 240 V) 11 KWT(380 / 400 V) 18.5 KWT(415 V) 22 KWT(440 V) 22 KWT(500 V) 22 KWT(690 V) 22 KWT(400 V) 18.5 KWT
Rated Operational Voltage
Auxiliary Circuit 690 VMain Circuit 690 V
Rated Short-time Withstand Current (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 Afor 0.1 s 140 Afor 1 s 100 A
Terminal Type
Screw Terminals
Tightening Torque
Auxiliary Circuit 1.2 N·mMain Circuit 4 N·mControl Circuit 1.2 N·m
Wire Stripping Length
Main Circuit 16 mm

Dimensions

Product Net Width
67 mm
Product Net Height
125.5 mm
Product Net Depth / Length
111 mm
Product Net Weight
1.01 kg

Container Information

Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Height
97 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Gross Weight
1.01 kg
Package Level 2 Units
box 10 piece
Package Level 2 Width
250 mm
Package Level 2 Height
300 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Gross Weight
10.1 kg
Package Level 3 Units
240 piece

Classifications

ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
ETIM 6
EC000066 - Power contactor, AC switching
ETIM 7
EC000066 - Power contactor, AC switching
Object Classification Code
Q
UNSPSC
39121529
WEEE Category
Product Not in WEEE Scope

Environmental

Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °CClose to Contactor without Thermal O/L Relay -40 ... +70 °CClose to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
Maximum Operating Altitude Permissible
3000 m
Resistance to Vibrations acc. to IEC 60068-2-6
5 ... 300 Hz 3 g closed position / 3 g open position
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: A 25 K40Closed, Shock Direction: B1 25 K40Closed, Shock Direction: B2 15 K40Closed, Shock Direction: C1 25 K40Closed, Shock Direction: C2 25 K40Open, Shock Direction: B1 5 K40

Technical UL/CSA

Horsepower Rating UL/CSA
(220 ... 240 V AC) Three Phase 15 hp(440 ... 480 V AC) Three Phase 30 hp(550 ... 600 V AC) Three Phase 40 hp(120 V AC) Single Phase 3 hp(200 ... 208 V AC) Three Phase 10 hp(240 V AC) Single Phase 7-1/2 hp
General Use Rating UL/CSA
(600 V AC) 60 A
Tightening Torque UL/CSA
Auxiliary Circuit 11 IAControl Circuit 11 IAMain Circuit 35 IA

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900