ABB

ASL09301086

ASL09-30-10-86 110VDC Contactor
ASL09301086
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Additional Information

Part Number
ASL09301086
UNSPSC
39121529
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power contactor, AC switching
Class Code : EC000066
Version : 7

Dimensions

Product Net Width
45 mm
Product Net Depth / Length
72.5 mm
Product Net Height
68 mm
Product Net Weight
0.28 kg

Technical

Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Standards
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Rated Operational Voltage
Auxiliary Circuit 690 VMain Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 22 Aacc. to IEC 60947-5-1, Θ = 40 °C 10 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 22 A(690 V) 60 °C 18 A(690 V) 70 °C 15 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 9 A(440 V) 60 °C 8 A(500 V) 60 °C 8 A(690 V) 60 °C 5 A(380 / 400 V) 60 °C 9 A(220 / 230 / 240 V) 60 °C 9 A
Rated Operational Power AC-3 (Pe)
(400 V) 4 kW(415 V) 4 kW(440 V) 4 kW(500 V) 4 kW(690 V) 4 kW(220 / 230 / 240 V) 2.2 kW
Rated Operational Current AC-15 (Ie)
(500 V) NC 2(500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 22 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 230 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 65 Afor 0.1 s 140 Afor 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour(AC-15) 1200 cycles per hour(AC-2 / AC-4) 300 cycles per hour(AC-3) 1200 cycles per hour(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 Vacc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
DC Operation 110 V
Operate Time
Between Coil De-energization and NC Contact Closing 15 ... 20 msBetween Coil De-energization and NO Contact Opening 13 ... 17 msBetween Coil Energization and NC Contact Opening 31 ... 53 msBetween Coil Energization and NO Contact Closing 36 ... 59 ms
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 9 mmControl Circuit 9 mmMain Circuit 9 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20IP20
Terminal Type
Screw Terminals

Classifications

Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
EClass
V11.0 : 27371018
IDEA Granular Category Code (IGCC)
4755 >> Contactors

Environmental

Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6
5 ... 300 Hz 3 g Closed position / 2 g Open position
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 10 gClosed, Shock Direction: C1 20 gClosed, Shock Direction: C2 20 gOpen, Shock Direction: B1 5 gOpen, Shock Direction: C1 9 gOpen, Shock Direction: C2 14 gShock Direction: A 20 gShock Direction: B2 15 g

Technical UL/CSA

General Use Rating UL/CSA
(600 V AC) 20 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 1/3 hp(200 ... 208 V AC) Three Phase 2 hp(220 ... 240 V AC) Three Phase 2 hp(240 V AC) Single Phase 1 hp(440 ... 480 V AC) Three Phase 5 hp(550 ... 600 V AC) Three Phase 7.5 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lbControl Circuit 9 in·lbMain Circuit 9 in·lb

Ordering

Minimum Order Quantity
40 piece
Customs Tariff Number
85364900