ABB

AX12-30-10-84

AX12-30-10-84 110V50Hz/110-120V60Hz Contactor
AX12-30-10-84
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Dimensions

Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg

Technical

Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 VMain Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 26 Aacc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 22 A(690 V) 40 °C 25 A(690 V) 70 °C 18 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 12 A(440 V) 55 °C 9 A(500 V) 55 °C 9 A(690 V) 55 °C 7 A(380 / 400 V) 55 °C 12 A(220 / 230 / 240 V) 55 °C 12 A
Rated Operational Power AC-3 (Pe)
(415 V) 5.5 kW(440 V) 4 kW(500 V) 5.5 kW(690 V) 5.5 kW(380 / 400 V) 5.5 kW(220 / 230 / 240 V) 3 kW
Rated Operational Current AC-15 (Ie)
(500 V) NC 2(500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(380 / 400 V) 3 A(400 / 440 V) 2 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 Afor 0.1 s 140 Afor 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour(AC-15) 1200 cycles per hour(AC-3) 1200 cycles per hour(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W(110 V) 1.1 A / 121 W(125 V) 1.1 A / 138 W(220 V) 0.55 A / 121 W(250 V) 0.55 A / 138 W(400 V) 2.8 A / 134 W(500 V) 2 A / 144 W
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 110 V60 Hz 110 ... 120 V
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 msBetween Coil De-energization and NO Contact Opening 4 ... 11 msBetween Coil Energization and NC Contact Opening 7 ... 21 msBetween Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20IP20
Terminal Type
Screw Terminals

Classifications

Object Classification Code
Q
EClass
V11.0 : 27371003
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707318

Environmental

Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
RoHS Status
Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical UL/CSA

General Use Rating UL/CSA
(600 V AC) 25 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3/4 hp(200 ... 208 V AC) Three Phase 3 hp(220 ... 240 V AC) Three Phase 3 hp(240 V AC) Single Phase 2 hp(440 ... 480 V AC) Three Phase 7.5 hp(550 ... 600 V AC) Three Phase 10 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lbControl Circuit 9 in·lbMain Circuit 9 in·lb

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900