S803N-D32

S803N-D32 High Performance MCB
S803N-D32
S803N-D32
S803N-D32
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up

Installation

Instructions and Manuals
2CCC413016M0008

Dimensions

Width in Number of Modular Spacings
4.5
Product Net Width
81 mm
Product Net Height
95 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
735 g
Size
3 modules
Built-In Depth (t2)
82.5 mm
Dimension Diagram
2CCC413003C0201

Technical

Standards
IEC/EN 60947-2, IEC/EN 60898-1
Tripping Characteristic
D
Type of Residual Current
standard version
Rated Voltage (Ur)
acc. to IEC 60947-2 690 V ACacc. to IEC 60947-2 375 V DCacc. to IEC 60898-1 400 V AC
Rated Operational Voltage
acc. to IEC 60898-1 400 V
Operational Voltage
Maximum 230/400 V ACMinimum 12 V AC
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Input Voltage Type
AC/DC
Rated Current (In)
32 A
Rated Operational Current (Ie)
32 A
Rated Short-Circuit Capacity
(230 V) 20 kA(400 V) 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(230 V) 36 kA(400 V) 4.5 kA
Rated Conditional Short-Circuit Current (Inc)
(230 V) 36 kA(400 V) 36 kA
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 / 415 V AC) 30 kA(254 / 440 V AC) 15 kA(400 / 690 V AC) 3 kA(125 V DC) 20 kA
Frequency (f)
50 ... 60 Hz
Rated Frequency (f)
50/60 Hz
Power Loss
9.6 Wat Rated Operating Conditions per Pole 3.2 W
Contact Position Indication
ON / OFF / TRIP
Energy Limiting Class
3
Electrical Endurance
10000 cycle
Mechanical Endurance
10000 cycle
Number of Poles
3
Number of Protected Poles
3
Overvoltage Category
IV
Tightening Torque
3.5 N·m31 in·lb
Release Type
D
Actuator Marking
I / O
Housing Material
Insulation group I, RAL 7035
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting Position
Any
Recommended Screw Driver
Pozidriv 2
Accessories Available
Yes
Remarks
Connection from top and bottomConnecting with CU onlyIP40 in enclosure with coverCage terminal with captive screw
Connecting Capacity
Flexible 0 … 50 mm²Rigid 0 … 70 mm²
Terminal Type
Screw Terminals

Classifications

ETIM 9
EC000042 - Miniature circuit breaker (MCB)
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B
Business To Business
CN8
85362020
EClass
V11.0 : 27141901
Object Classification Code
F

Environmental

Ambient Temperature
-25...60 °C
Ambient Air Temperature
Operation -25 … 60 °C
Reference Ambient Air Temperature
acc. to IEC60947-2 30 °Cacc. to EN60898-1 30 °C
Degree of Protection
IP20
Pollution Degree
3
Resistance to Vibrations acc. to IEC 60068-2-6
2 - 13.2 Hz / 1mm13.2 - 100Hz / 0.7gwith load 100% x Ie
Resistance to Shock acc. to IEC 60068-2-27
5 g30 ms
RoHS Status
Following EU Directive 2011/65/EU
RoHS Information
9AKK107680A3903 2CCC005083D0202
Environmental Information
2CCY413207D0203
Conflict Minerals Reporting Template (CMRT)
9AKK108468A3363

Ordering

Minimum Order Quantity
1 piece
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
770 g