Belden
1633ES.00500
1633ES.00500 - Cat 5e Cable, SF/UTP, PVC, 4 Pair, AWG 24, Indoor CPR Eca
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
€706.20
1
Payment methods:
A total of 6,500 Parts In-Stock from 2 Distributors
Product Conditions:
Specifications
- Color
- Gray
- Length
- 500 m
Product Overview
- Suitable Applications
- Horizontal and building backbone cable; Support current and future Category 5e applications, such as: 1000Base-T (Gigabit Ethernet), 100 Base-T, 10 Base-T, FDDI, ATM
Physical Characteristics (Overall)
- Conductor Count
- 8
- Outer Shield Table Note
- Aluminum facing outside in contact with drain wire
- Bonded-Pair
- No
- Total Number of Pairs
- 4
Construction and Dimensions
- Min Elongation at Breakof Conductors
- 10 %
- Min Elongation at Breakof Insulation
- 100 %
- Min Elongation at Breakof Jacket
- 100 %
- Min Tensile Strength of Jacket
- 9 MPa
Electrical Characteristics
- High Freq Table Note
- Limits below 4 MHz are for information only. Reference standard: ISO/IEC 61156-5 ed. 2.0 (2009)
- General Electrical Parameters Notes
- Reference standard: ISO/IEC 61156-5 ed. 2.0 (2009)
- Coupling Attenuation Class
- Type II
- Segregation class according EN50174-2
- c
Temperature Range
- Installation Temp Range
- 0°C To +50°C
- Operating Temp Range
- -30°C To +60°C
Mechanical Characteristics
- Bulk Cable Weight
- 45 kg/km
- Max Recommended Pulling Tension
- 72 N
- Min Bend Radius During Installation
- 48 mm
- Min Bend Radius During Operation
- 24 mm
Standards
- ISO/IEC Compliance
- ISO/IEC 11801 Ed. 2.2:2002/A2:2010/C1:2011
- CPR Euroclass
- Eca
- CENELEC Compliance
- EN 50173-1 Ed. 3:2011
- Data Category
- Category 5e
- ANSI Compliance
- ANSI/TIA 568.2-D (2018)
- IEEE Specification
- PoE: IEEE 802.3bt Type 1, Type 2, Type 3
Applicable Environmental and Other Programs
- Environmental Space
- Indoor - Euroclass Eca
- EU RoHS Compliance Date (yyyy-mm-dd)
- 2005-01-01
Flammability, LS0H, Toxicity Testing
- ISO/IEC Flammability
- IEC 60332-1-2
- Burning Load
- 455 kJ/m
Part Number
- Patent
- https://www.belden.com/resources/patents
History
- Update and Revision
- Revision Number: 0.209 Revision Date: 09-17-2019