AWG
- # Pairs
- 12
- AWG
- 16
- Stranding
- 7x24
- Conductor Material
- TC - Tinned Copper
- Total Number of Conductors
- 24
Insulation Material
- Insulation Material
- PVC - Polyvinyl Chloride
- Wall Thickness (in.)
- .025
Inner Shield Material
- Inner Shield Trade Name
- Beldfoil®
- Type
- Tape
- Inner Shield Material
- Aluminum Foil-Polyester Tape
- Coverage (%)
- 100
Inner Shield Drain Wire AWG
- AWG
- 18
- Inner Shield Drain Wire Stranding
- 7x26
- Inner Shield Drain Wire Conductor Material
- TC - Tinned Copper
Inner Jacket Material
- Inner Jacket Material
- PVC - Polyvinyl Chloride
- Nom Wall (in.)
- 0.083
- Nom. Dia. (in.)
- 1.006
Outer Shield Material
- Outer Shield Trade Name
- Beldfoil®
- Type
- Tape
- Outer Shield Material
- Aluminum Foil-Polyester Tape
- Coverage (%)
- 100
Outer Shield Drain Wire AWG
- AWG
- 16
- Stranding
- 7x24
- Drain Wire Conductor Material
- TC - Tinned Copper
Outer Jacket Material
- Outer Jacket Material
- PVC - Polyvinyl Chloride
- Outer Jacket Ripcord
- Yes
- Outer Jacket over Armor (y/n)
- Y
Armor
- Armor Type
- Interlocked Armor
- Armor Material
- Aluminum
- Diameter over Armor
- 1.266
Overall Cable
- Overall Nominal Diameter
- 1.370 in.
Mechanical Characteristics
- Installation Temperature Range
- -25°C To +105°C
- Wet Temperature Range
- -40°C To +75°C
- Dry Temperature Range
- -40°C To +105°C
- Non-UL Temperature Rating
- 150°C
- Bulk Cable Weight
- 875 lbs/1000 ft.
- Max. Recommended Pulling Tension
- 200 lbs.
- Min. Bend Radius/Minor Axis
- 16.500 in.
Applicable Standards & Environmental Programs
- CSA Specification
- C22.2 #239 Type ACIC, C22.2 #174 HL BCD
- EU Directive 2011/65/EU (ROHS II)
- Yes
- EU Directive 2000/53/EC (ELV)
- Yes
- EU Directive 2002/95/EC (RoHS)
- Yes
- EU RoHS Compliance Date (mm/dd/yyyy)
- 01/01/2006
- EU Directive 2002/96/EC (WEEE)
- Yes
- EU Directive 2003/11/EC (BFR)
- Yes
- CA Prop 65 (CJ for Wire & Cable)
- Yes
- MII Order #39 (China RoHS)
- Yes
Flame Test
- C(UL) Flame Test
- FT4
Suitability
- Suitability - Indoor
- Yes
- Suitability - Outdoor
- Yes
Plenum/Non-Plenum
- Plenum (Y/N)
- No
Nom. Conductor DC Resistance
- DCR @ 20°C (Ohm/1000 ft)
- 4.2
Nominal Outer Shield DC Resistance
- DCR @ 20°C (Ohm/1000 ft)
- 4
- Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C
- 10 Ohm/1000 ft
Max. Operating Voltage - Non-UL
- Voltage
- 300
- Description
- CEC ACIC
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther